Volumn 18, Issue 3, 2011, Pages 692-700

Influence of vegetable oil on the thermal aging of transformer paper and its mechanism

Author keywords

accelerated thermal aging; degree of polymerization (DP); electrical insulation; molecular simulation; oil paper; Power transformer; X ray photoelectron spectroscopy (XPS)

Indexed keywords

ACCELERATED THERMAL AGING; DEGREE OF POLYMERIZATION; ELECTRICAL INSULATION; MOLECULAR SIMULATIONS; OIL-PAPERS; X-RAY PHOTOELECTRON SPECTROSCOPY (XPS);

EID: 79959988054     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2011.5931054     Document Type: Article
Times cited : (139)

References (29)
  • 1
    • 0032074157 scopus 로고    scopus 로고
    • Mineral insulating oil in transformers
    • T. O. Rouse, "Mineral insulating oil in transformers", IEEE Electr. Insul. Mag., Vol. 14, No.3, pp. 6-16, 1998. (Pubitemid 128556749)
    • (1998) IEEE Electrical Insulation Magazine , vol.14 , Issue.3 , pp. 6-16
    • Rouse, T.O.1
  • 2
    • 0036505924 scopus 로고    scopus 로고
    • Letter to the editor
    • DOI 10.1109/MEI.2002.1014962
    • C. P. McShane, "Letter to the editor", IEEE Electr. Insul. Mag., Vol. 18, No.3, pp. 6-7, 2002. (Pubitemid 34808245)
    • (2002) IEEE Electrical Insulation Magazine , vol.18 , Issue.3 , pp. 6-7
    • McShane, C.P.1
  • 3
    • 0036197052 scopus 로고    scopus 로고
    • Vegetable oils for liquid-filled transformers
    • DOI 10.1109/57.981322
    • T. V. Oommen, "Vegetable oils for liquid-filled transformers", IEEE Electr. Insul. Mag., Vol. 18, No.1,, pp. 6-11, 2002. (Pubitemid 34255608)
    • (2002) IEEE Electrical Insulation Magazine , vol.18 , Issue.1 , pp. 6-11
    • Oommen, T.V.1
  • 5
    • 0032637967 scopus 로고    scopus 로고
    • Furfural analysis for assessing degradation of thermally upgraded papers in transformer insulation
    • R. M. Morais, W. A. Mannheimer, M. Carballeira, and J. C. Noualhaguet, "Furfural analysis for assessing degradation of thermally upgraded papers in transformer insulation", IEEE Trans. Dielectr. Electr. Insul., Vol. 6, No.2, pp. 159-163, 1999.
    • (1999) IEEE Trans. Dielectr. Electr. Insul. , vol.6 , Issue.2 , pp. 159-163
    • Morais, R.M.1    Mannheimer, W.A.2    Carballeira, M.3    Noualhaguet, J.C.4
  • 6
    • 0033732347 scopus 로고    scopus 로고
    • Degradation of cellulosic insulation in power transformers. Part 3: Effects of oxygen and water on ageing in oil
    • A. M. Emsley, X. Xiao, R. J. Heywood, and M. Ali, "Degradation of cellulosic insulation in power transformers. Part 3: Effects of oxygen and water on ageing in oil", IEE Proc. Sci., Measurement Techn., Vol. 147, No.3, pp. 115-119, 2000.
    • (2000) IEE Proc. Sci., Measurement Techn. , vol.147 , Issue.3 , pp. 115-119
    • Emsley, A.M.1    Xiao, X.2    Heywood, R.J.3    Ali, M.4
  • 7
    • 0031257386 scopus 로고    scopus 로고
    • Electrical and chemical diagnostics of transformers insulation-part A: Aged transformer samples
    • T. K. Saha, M. Darveniza, D. J. T. Hill, and T. T. Le, "Electrical and chemical diagnostics of transformers insulation. A: Aged transformer samples", IEEE Trans. Power Delivery, Vol. 12, No.4, pp. 1547-1554, 1997. (Pubitemid 127827641)
    • (1997) IEEE Transactions on Power Delivery , vol.12 , Issue.4 , pp. 1547-1554
    • Saha, T.K.1    Darveniza, M.2    Hill, D.J.T.3    Le, T.T.4
  • 8
    • 0028496219 scopus 로고
    • Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers
    • A. M. Emsley and G. C. Stevens, "Review of chemical indicators of degradation of cellulosic electrical paper insulation in oil-filled transformers", IEE Proc. Sci., Measurement Techn., Vol. 141, No.5, pp. 324-334, 1994.
    • (1994) IEE Proc. Sci., Measurement Techn. , vol.141 , Issue.5 , pp. 324-334
    • Emsley, A.M.1    Stevens, G.C.2
  • 9
    • 77954206300 scopus 로고    scopus 로고
    • Oil-paper aging evaluation by fuzzy clustering and factor analysis to statistical parameters of partial discharges
    • J. Li, R. Liao, S. Grzybowski, and L. Yang, "Oil-paper aging evaluation by fuzzy clustering and factor analysis to statistical parameters of partial discharges", IEEE Trans. Dielectr. Electr. Insul., Vol. 17, No.3, pp. 756-763.
    • IEEE Trans. Dielectr. Electr. Insul. , vol.17 , Issue.3 , pp. 756-763
    • Li, J.1    Liao, R.2    Grzybowski, S.3    Yang, L.4
  • 10
    • 73649111042 scopus 로고    scopus 로고
    • Aging effect on electrical characteristics of insulating oil in field transformer
    • M. Kohtoh, S. Kaneko, S. Okabe, and T. Amimoto, "Aging effect on electrical characteristics of insulating oil in field transformer", IEEE Trans. Dielectr. Electr. Insul., Vol. 16, No.6, pp. 1698-1706, 2009.
    • (2009) IEEE Trans. Dielectr. Electr. Insul. , vol.16 , Issue.6 , pp. 1698-1706
    • Kohtoh, M.1    Kaneko, S.2    Okabe, S.3    Amimoto, T.4
  • 11
    • 77954187401 scopus 로고    scopus 로고
    • Transformer insulating oil characteristic changes observed using accelerated degradation in consideration of field transformer conditions
    • M. Kohtoh, G. Ueta, S. Okabe, and T. Amimoto, "Transformer insulating oil characteristic changes observed using accelerated degradation in consideration of field transformer conditions", IEEE Trans. Dielectr. Electr. Insul., Vol. 17, No.3, pp. 808-818.
    • IEEE Trans. Dielectr. Electr. Insul. , vol.17 , Issue.3 , pp. 808-818
    • Kohtoh, M.1    Ueta, G.2    Okabe, S.3    Amimoto, T.4
  • 12
    • 78650060366 scopus 로고    scopus 로고
    • Vegetable oils, an alternative to mineral oil for power transformers- experimental study of paper aging in vegetable oil versus mineral oil
    • M. A. G. Martins, "Vegetable oils, an alternative to mineral oil for power transformers- experimental study of paper aging in vegetable oil versus mineral oil", Electr. Insul. Mag., Vol. 26, No.6, pp. 7-13.
    • Electr. Insul. Mag. , vol.26 , Issue.6 , pp. 7-13
    • Martins, M.A.G.1
  • 14
    • 0032643320 scopus 로고    scopus 로고
    • Fire resistant natural ester dielectric fluid and novel insulation system for its use
    • New Orleans, LA.
    • C. P. McShane, G. A. Gauger, and J. Luksich, "Fire resistant natural ester dielectric fluid and novel insulation system for its use", IEEE Transmission and Distribution Conference, New Orleans, LA. , pp. 890-894, 1999.
    • (1999) IEEE Transmission and Distribution Conference , pp. 890-894
    • McShane, C.P.1    Gauger, G.A.2    Luksich, J.3
  • 17
    • 79959938637 scopus 로고    scopus 로고
    • Standard test method for measurement of average viscometric degree of polymerization of new and aged electrical papers and boards
    • ASTM
    • ASTM: " Standard Test Method for Measurement of Average Viscometric Degree of Polymerization of New and Aged Electrical Papers and Boards", ASTM D 4243-99 2004.
    • (2004) ASTM D , pp. 4243-4299
  • 18
    • 0005578965 scopus 로고    scopus 로고
    • Life assessment of cable paper using slow thermal ramp methods
    • PII S0040603199000738
    • R. J. Heywood, G. C. Stevens, C. Ferguson, and A. M. Emsley, "Life assessment of cable paper using slow thermal ramp methods", Thermochimica Acta, Vol. 332, No.2,pp. 189-195, 1999. (Pubitemid 129498118)
    • (1999) Thermochimica Acta , vol.332 , Issue.2 , pp. 189-195
    • Heywood, R.J.1    Stevens, G.C.2    Ferguson, C.3    Emsley, A.M.4
  • 19
    • 27744592802 scopus 로고    scopus 로고
    • The influence of levelling-off degree of polymerisation on the kinetics of cellulose degradation
    • DOI 10.1007/s10570-005-2206-z
    • P. Calvini, "The Influence of Levelling-off Degree of Polymerisation on the Kinetics of Cellulose Degradation", Cellulose, Vol. 12, No.4, pp. 445-447, 2005. (Pubitemid 41600141)
    • (2005) Cellulose , vol.12 , Issue.4 , pp. 445-447
    • Calvini, P.1
  • 20
    • 0034507387 scopus 로고    scopus 로고
    • Wear-out approach for predicting the remaining lifetime of materials
    • DOI 10.1016/S0141-3910(00)00112-9
    • K. T. Gillen and M. Celina, "The wear-out approach for predicting the remaining lifetime of materials", Polymer Degradation and Stability, Vol. 71,No.1, pp. 15-30, 2000. (Pubitemid 32029202)
    • (2000) Polymer Degradation and Stability , vol.71 , Issue.1 , pp. 15-30
    • Gillen, K.T.1    Celina, M.2
  • 21
    • 33745902802 scopus 로고    scopus 로고
    • Time-temperature superposition to determine the stress-rupture of aramid fibres
    • DOI 10.1007/s10443-006-9017-8
    • K. Alwis and C. Burgoyne, "Time-Temperature Superposition to Determine the Stress-Rupture of Aramid Fibres", Applied Composite Materials, Vol. 13, No.4, pp. 249-264, 2006. (Pubitemid 44048465)
    • (2006) Applied Composite Materials , vol.13 , Issue.4 , pp. 249-264
    • Alwis, K.G.N.C.1    Burgoyne, C.J.2
  • 22
    • 34248402870 scopus 로고    scopus 로고
    • Time - Temperature superposition method for predicting the permanence of paper by extrapolating accelerated ageing data to ambient conditions
    • DOI 10.1007/s10570-007-9114-3
    • H. Z. Ding and Z. Wang, "Time-temperature superposition method for predicting the permanence of paper by extrapolating accelerated ageing data to ambient conditions", Cellulose, Vol. 14, No.3, pp. 171-181, 2007. (Pubitemid 46730743)
    • (2007) Cellulose , vol.14 , Issue.3 , pp. 171-181
    • Ding, H.-Z.1    Wang, Z.D.2
  • 24
    • 18444391220 scopus 로고    scopus 로고
    • Variation of dielectric strength of a insulation paper with thermal aging
    • DOI 10.1016/j.ndteint.2004.12.006, PII S0963869505000150
    • A. Joshi and S. Kumar, "Variation of dielectric strength of a insulation paper with thermal aging", NDT & E International, Vol. 38, No.6, pp. 459-461, 2005. (Pubitemid 40643086)
    • (2005) NDT and E International , vol.38 , Issue.6 , pp. 459-461
    • Joshi, A.1    Kumar, S.2
  • 25
    • 0036564061 scopus 로고    scopus 로고
    • Challenge of mixed insulating liquids for use in high-voltage transformers, Part 1: Investigation of mixed liquids
    • DOI 10.1109/MEI.2002.1014964
    • I. Fofana, V. Wasserberg, H. Borsi, and E. Gockenbach, "Challenge of mixed insulating liquids for use in high-voltage transformers.1. Investigation of mixed liquids", IEEE Electr. Insul. Mag., Vol. 18, No.3, pp. 18-31, 2002. (Pubitemid 34808247)
    • (2002) IEEE Electrical Insulation Magazine , vol.18 , Issue.3 , pp. 18-31
    • Fofana, I.1    Wasserberg, V.2    Borsi, H.3    Gockenbach, E.4
  • 26
    • 0035076502 scopus 로고    scopus 로고
    • Low temperature thermal degradation of cellulosic insulating paper in air and transformer oil
    • N. M. R. F. H. E. R. Sandra Soares, "Low temperature thermal degradation of cellulosic insulating paper in air and transformer oil", Polymer Intern., Vol. 50, No.3, pp. 303-308, 2001.
    • (2001) Polymer Intern. , vol.50 , Issue.3 , pp. 303-308
    • Sandra Soares, N.M.R.F.H.E.R.1
  • 27
    • 0000180556 scopus 로고
    • Surface characterization of cellulose fibres by XPS and inverse gas chromatography
    • M. N. Belgacem, G. Czeremuszkin, S. Sapieha, and A. Gandini, "Surface characterization of cellulose fibres by XPS and inverse gas chromatography", Cellulose, Vol. 2, No.3, pp. 145-157, 1995.
    • (1995) Cellulose , vol.2 , Issue.3 , pp. 145-157
    • Belgacem, M.N.1    Czeremuszkin, G.2    Sapieha, S.3    Gandini, A.4
  • 28
    • 0028769281 scopus 로고
    • Synthesis and characterization of long-chain fatty acid cellulose ester (FACE)
    • W. Pinglang and Y. T. Bernard, "Synthesis and characterization of long-chain fatty acid cellulose ester (FACE)", J. Appl. Polymer Sci., Vol. 52, No.6, pp. 755-761, 1994.
    • (1994) J. Appl. Polymer Sci. , vol.52 , Issue.6 , pp. 755-761
    • Pinglang, W.1    Bernard, Y.T.2
  • 29
    • 77953112629 scopus 로고    scopus 로고
    • Characteristic comparison between paraffine-base and naphthene-base transformer oils
    • L. Fenglin and X. Wei, "Characteristic Comparison between Paraffine-Base and Naphthene-Base Transformer Oils", Transformer, Vol. 41, No.7, pp. 27-29, 2004.
    • (2004) Transformer , vol.41 , Issue.7 , pp. 27-29
    • Fenglin, L.1    Wei, X.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.