메뉴 건너뛰기




Volumn 34, Issue 6, 2011, Pages 495-505

An ex vivo platform to simulate cardiac physiology: A new dimension for therapy development and assessment

Author keywords

Blood pumps; Cardiac hemodynamics; Cardiac implants; Electrophysiology; Ex vivo model; Isolated beating heart

Indexed keywords

ELECTROPHYSIOLOGY; HEMODYNAMICS; PHYSIOLOGICAL MODELS;

EID: 79959983862     PISSN: 03913988     EISSN: None     Source Type: Journal    
DOI: 10.5301/IJAO.2011.8456     Document Type: Article
Times cited : (60)

References (24)
  • 1
    • 34447581554 scopus 로고
    • Untersuchungen am Überlebenden Säugethierherzen. Pflügers Arch
    • Langendorff O. Untersuchungen am Überlebenden Säugethierherzen. Pflügers Arch: European Journal of Physiology. 1895;61(6):291-332. doi:10.1007/BF01812150
    • (1895) Pflügers Arch: European Journal of Physiology , vol.61 , Issue.6 , pp. 291-332
    • Langendorff, O.1
  • 2
    • 0024444063 scopus 로고
    • Influence of mitral valve prosthesis or rigid mitral ring on left ventricular pump function. A study on exposed and isolated blood-perfused porcine hearts
    • van Rijk-Zwikker GL, Schipperheyn JJ, Huysmans HA, Bruschke AV. Influence of mitral valve prosthesis or rigid mitral ring on left ventricular pump function. A study on exposed and isolated blood-perfused porcine hearts. Circulation. 1989;80(3 Pt 1):I1-I7.
    • (1989) Circulation , vol.80 , Issue.3 PART 1
    • van Rijk-Zwikker, G.L.1    Schipperheyn, J.J.2    Huysmans, H.A.3    Bruschke, A.V.4
  • 4
  • 5
    • 23844502282 scopus 로고    scopus 로고
    • Pressure-volume relationship in isolated working heart with crystalloid perfusate in swine and imaging the valve motion
    • Medline. doi:10.1016/j. ejcts.2005.06.015
    • Araki Y, Usui A, Kawaguchi O, et al. Pressure-volume relationship in isolated working heart with crystalloid perfusate in swine and imaging the valve motion. Eur J Cardiothorac Surg. 2005;28(3):435-442. Medline. doi:10.1016/j. ejcts.2005.06.015
    • (2005) Eur J Cardiothorac Surg , vol.28 , Issue.3 , pp. 435-442
    • Araki, Y.1    Usui, A.2    Kawaguchi, O.3
  • 6
    • 33748292886 scopus 로고    scopus 로고
    • Mitral valve motion assessed by high-speed video camera in isolated swine heart
    • Medline. doi:10.1016/j.ejcts.2006.07.021
    • Saito S, Araki Y, Usui A, et al. Mitral valve motion assessed by high-speed video camera in isolated swine heart. Eur J Cardiothorac Surg. 2006;30(4):584-591. Medline. doi:10.1016/j.ejcts.2006.07.021
    • (2006) Eur J Cardiothorac Surg , vol.30 , Issue.4 , pp. 584-591
    • Saito, S.1    Araki, Y.2    Usui, A.3
  • 7
    • 0033763062 scopus 로고    scopus 로고
    • Isolated fourchamber working swine heart model
    • Medline. doi:10.1016/S0003-4975(00)01977-9
    • Chinchoy E, Soule CL, Houlton AJ, et al. Isolated fourchamber working swine heart model. Ann Thorac Surg. 2000;70(5):1607-1614. Medline. doi:10.1016/S0003-4975(00)01977-9
    • (2000) Ann Thorac Surg , vol.70 , Issue.5 , pp. 1607-1614
    • Chinchoy, E.1    Soule, C.L.2    Houlton, A.J.3
  • 8
    • 27444431935 scopus 로고    scopus 로고
    • A novel ex vivo heart model for the assessment of cardiac pacing systems
    • Medline. doi:10.1115/1.2049312
    • Laske TG, Skadsberg ND, Iaizzo PA. A novel ex vivo heart model for the assessment of cardiac pacing systems.J Biomech Eng. 2005;127(6):894-898. Medline. doi:10.1115/1.2049312
    • (2005) J Biomech Eng , vol.127 , Issue.6 , pp. 894-898
    • Laske, T.G.1    Skadsberg, N.D.2    Iaizzo, P.A.3
  • 9
    • 33746214565 scopus 로고    scopus 로고
    • In vivo versus in vitro comparison of swine cardiac performance: Induction of cardiodepression with halothane
    • Medline. doi:10.1016/j.ejphar.2006.06.011
    • Sigg DC, Iaizzo PA. In vivo versus in vitro comparison of swine cardiac performance: induction of cardiodepression with halothane. Eur J Pharmacol. 2006;543(1-3):97-107.Medline. doi:10.1016/j.ejphar.2006.06.011
    • (2006) Eur J Pharmacol , vol.5 , Issue.1-2 , pp. 97-107
    • Sigg, D.C.1    Iaizzo, P.A.2
  • 10
    • 0028241336 scopus 로고
    • Isolated in-vitro perfusion of pig hearts obtained from the abattoir: An alternative to animal experiments?
    • Görge G, Erbel R, Dobbertin A, Hanggi M, Hake U, Meyer J. Isolated in-vitro perfusion of pig hearts obtained from the abattoir: an alternative to animal experiments? Eur Heart J. 1994;15(6):851-857.
    • (1994) Eur Heart J , vol.15 , Issue.6 , pp. 851-857
    • Görge, G.1    Erbel, R.2    Dobbertin, A.3    Hanggi, M.4    Hake, U.5    Meyer, J.6
  • 12
    • 0015147582 scopus 로고
    • An artificial arterial sys tem for pumping hearts
    • Westerhof N, Elzinga G, Sipkema P. An artificial arterial sys tem for pumping hearts. J Appl Physiol. 1971;31(5):776-781.
    • (1971) J Appl Physiol , vol.31 , Issue.5 , pp. 776-781
    • Westerhof, N.1    Elzinga, G.2    Sipkema, P.3
  • 13
    • 0032932939 scopus 로고    scopus 로고
    • Total arterial inertance as the fourth element of the windkessel model
    • Stergiopulos N, Westerhof BE, Westerhof N. Total arterial inertance as the fourth element of the windkessel model. Am J Physiol. 1999;276(1 Pt 2):H81-H88.
    • (1999) Am J Physiol , vol.276 , Issue.1 PART 2
    • Stergiopulos, N.1    Westerhof, B.E.2    Westerhof, N.3
  • 14
    • 60649099988 scopus 로고    scopus 로고
    • The arterial Windkessel
    • Medline. doi:10.1007/s11517-008-0359-2
    • Westerhof N, Lankhaar JW, Westerhof BE. The arterial Windkessel. Med Biol Eng Comput. 2009;47(2):131-141. Medline. doi:10.1007/s11517-008-0359-2
    • (2009) Med Biol Eng Comput , vol.47 , Issue.2 , pp. 131-141
    • Westerhof, N.1    Lankhaar, J.W.2    Westerhof, B.E.3
  • 15
    • 18344413423 scopus 로고
    • End-diastolic and end-systolic ventricular volume clamper for isolated canine heart
    • Suga H, Sagawa K. End-diastolic and end-systolic ventricular volume clamper for isolated canine heart. Am J Physiol. 1977;233(6):H718-H722.
    • (1977) Am J Physiol , vol.233 , Issue.6
    • Suga, H.1    Sagawa, K.2
  • 16
    • 0020173090 scopus 로고
    • Impedance loading servo pump system for excised canine ventricle
    • Sunagawa K, Burkhoff D, Lim KO, Sagawa K. Impedance loading servo pump system for excised canine ventricle. Am J Physiol. 1982;243:H346-H350.
    • (1982) Am J Physiol , vol.243
    • Sunagawa, K.1    Burkhoff, D.2    Lim, K.O.3    Sagawa, K.4
  • 18
    • 4344593862 scopus 로고    scopus 로고
    • A physiologically representative in vitro model of the coronary circulation
    • Medline. doi:10.1088/0967-3334/25/4/009
    • Geven MC, Bohte VN, Aarnoudse WH, et al. A physiologically representative in vitro model of the coronary circulation. Physiol Meas. 2004;25:891-904. Medline. doi:10.1088/0967-3334/25/4/009
    • (2004) Physiol Meas , vol.25 , pp. 891-904
    • Geven, M.C.1    Bohte, V.N.2    Aarnoudse, W.H.3
  • 19
    • 79959920877 scopus 로고    scopus 로고
    • http://www.visibleheart.com
  • 20
    • 77950875462 scopus 로고    scopus 로고
    • Images in cardiovascular medicine. Direct endoscopic visual assessment of a transcatheter aortic valve implantation and performance in the Physioheart, an isolated working heart platform
    • Medline. doi:10.1161/CIR.0b013e3181d9b879
    • de Weger A, van Tuijl S, Stijnen M, Steendijk P, de Hart J. Images in cardiovascular medicine. Direct endoscopic visual assessment of a transcatheter aortic valve implantation and performance in the Physioheart, an isolated working heart platform. Circulation. 2010;121(13):e261-e262. Medline. doi:10.1161/CIR.0b013e3181d9b879
    • (2010) Circulation , vol.121 , Issue.13
    • de Weger, A.1    van Tuijl, S.2    Stijnen, M.3    Steendijk, P.4    de Hart, J.5
  • 22
    • 0037414073 scopus 로고    scopus 로고
    • Left ventricular support by catheter-mounted axial flow pump reduces infarct size
    • Medline. doi:10.1016/S0735-1097(03)00084-6
    • Meyns B, Stolinski J, Leunens V, Verbeken E, Flameng W. Left ventricular support by catheter-mounted axial flow pump reduces infarct size. J Am Coll Cardiol. 2003;41(7):1087-1095. Medline. doi:10.1016/S0735-1097(03)00084-6
    • (2003) J Am Coll Cardiol , vol.41 , Issue.7 , pp. 1087-1095
    • Meyns, B.1    Stolinski, J.2    Leunens, V.3    Verbeken, E.4    Flameng, W.5
  • 23
    • 0037402766 scopus 로고    scopus 로고
    • A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve
    • Medline. doi:10.1016/S0021-9290(02)00448-7
    • De Hart J, Peters GWM, Schreurs PJG, Baaijens FPT. A computational fluid-structure interaction analysis of a fiber-reinforced stentless aortic valve. J Biomech. 2003;36(5):699-712. Medline. doi:10.1016/S0021-9290(02)00448-7
    • (2003) J Biomech , vol.36 , Issue.5 , pp. 699-712
    • de Hart, J.1    Peters, G.W.M.2    Schreurs, P.J.G.3    Baaijens, F.P.T.4
  • 24
    • 0024426047 scopus 로고
    • Studies of myocardial metabolism using P-31-NMR spectroscopy and a simple heart perfusion model of slaughtered animals - an approach to avoiding in vivo animal experiments
    • Henze E, Schoser K, Lietzenmayer R, et al. Studies of myocardial metabolism using P-31-NMR spectroscopy and a simple heart perfusion model of slaughtered animals - an approach to avoiding in vivo animal experiments. Z Kardiol 1989;78(9): 553-560.
    • (1989) Z Kardiol , vol.78 , Issue.9 , pp. 553-560
    • Henze, E.1    Schoser, K.2    Lietzenmayer, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.