메뉴 건너뛰기




Volumn , Issue , 2011, Pages

Dynamic contribution of DFIG along with SMES for load frequency control of interconnected restructured power system

Author keywords

deregulation; doubly fed induction generator; frequency regulation; particle swarm optimization; smes

Indexed keywords

ACTIVE POWER; DOUBLY FED INDUCTION GENERATORS; DOUBLY-FED INDUCTION GENERATOR; FREQUENCY REGULATIONS; HIGHER FREQUENCIES; INTEGRAL GAIN; LOAD DEMAND; LOAD PERTURBATIONS; LOAD-FREQUENCY CONTROL; PARTICLE SWARM; POWER ELECTRONICS CONVERTERS; RATE OF CHANGE OF FREQUENCIES; RESTRUCTURED POWER SYSTEMS; SMES; SUPERCONDUCTING MAGNETIC ENERGY STORAGES; SUPPORT FUNCTIONS; TIE-LINE; TRANSIENT PERFORMANCE;

EID: 79959976124     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EEEIC.2011.5874848     Document Type: Conference Paper
Times cited : (14)

References (6)
  • 1
    • 3342969237 scopus 로고    scopus 로고
    • Power system frequency response from fixed speed and doubly fed induction generator-based wind turbines
    • DOI 10.1002/we.105
    • L. Holdsworth, J. Ekanayake, and N. Jenkins, "Power system frequency response from fixed speed and doubly-fed induction generator based wind turbine," Wind Energy, vol. 7, pp. 21-35, 2004. (Pubitemid 40290426)
    • (2004) Wind Energy , vol.7 , Issue.1 , pp. 21-35
    • Holdsworth, L.1    Ekanayake, J.B.2    Jenkins, N.3
  • 2
    • 0026910692 scopus 로고
    • Effect of superconducting magnetic energy storage on automatic generation control considering governor deadband and boiler dynamics
    • DOI 10.1109/59.207343
    • Tripathy SC, Balasubramanian R and Chandramohanan Nair PS. "Effect of superconducting magnetic energy storage on automatic generation control considering governor deadband and boiler dynamics", IEEE Trans. Power Syst., vol. 7, no. 3, pp.1266-73, 1992 (Pubitemid 23563439)
    • (1992) IEEE Transactions on Power Systems , vol.7 , Issue.3 , pp. 1266-1273
    • Tripathy, S.C.1    Balasubramanian, R.2    Chandramohanan Nair, P.S.3
  • 3
    • 76349117445 scopus 로고    scopus 로고
    • Optimized multiarea AGC simulation in restructured power systems
    • May
    • P. Bhatt, R. Roy and S.P. Ghoshal, "Optimized Multiarea AGC Simulation in Restructured Power Systems", Int. Journal of Elect. Power and Energy Syst., vol. 32, issue. 4, pp. 311-322, May 2010
    • (2010) Int. Journal of Elect. Power and Energy Syst. , vol.32 , Issue.4 , pp. 311-322
    • Bhatt, P.1    Roy, R.2    Ghoshal, S.P.3
  • 5
    • 41149122773 scopus 로고    scopus 로고
    • A novel crazy swarm optimized economic load dispatch for various types of cost functions
    • DOI 10.1016/j.ijepes.2007.07.007, PII S0142061507000981
    • R. Roy, S.P. Ghoshal, "A novel crazy optimized economic load dispatch for various types of cost functions", Int. Journal of Elect. Power Energy Syst, vol. 30, no. 4, pp. 242-253, 2008 (Pubitemid 351434441)
    • (2008) International Journal of Electrical Power and Energy Systems , vol.30 , Issue.4 , pp. 242-253
    • Roy, R.1    Ghoshal, S.P.2
  • 6
    • 43849103784 scopus 로고    scopus 로고
    • Temporary primary frequency control support by variable speed wind turbines - Potential and applications
    • DOI 10.1109/TPWRS.2008.920076
    • Nayeem Rahmat Ullah, Torbjörn Thiringer, and Daniel Karlsson, "Temporary Primary Frequency Control Support by Variable Speed Wind Turbines- Potential and Applications", IEEE Trans. Power Syst., vol. 23, no. 2, pp. 601-612, May. 2008 (Pubitemid 351695839)
    • (2008) IEEE Transactions on Power Systems , vol.23 , Issue.2 , pp. 601-612
    • Ullah, N.R.1    Thiringer, T.2    Karlsson, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.