메뉴 건너뛰기




Volumn 49, Issue 7, 2011, Pages 817-821

Clinical evaluation of a newly developed catheter (SpeediCath Compact Male) in men with spinal cord injury: Residual urine and user evaluation

Author keywords

intermittent catheterization; male; residual urine; ultrasound

Indexed keywords

ADULT; AGED; ARTICLE; BLADDER CATHETERIZATION; BLADDER EMPTYING; BLEEDING; BURNING SENSATION; CATHETER; CLINICAL ARTICLE; CLINICAL EVALUATION; CLINICAL TRIAL; CROSSOVER PROCEDURE; DEVICE SAFETY; ECHOGRAPHY; HUMAN; MALE; MULTICENTER STUDY; PRIORITY JOURNAL; PROSPECTIVE STUDY; RESIDUAL URINE; SPINAL CORD INJURY; STANDARD; URETHRA DISEASE;

EID: 79959908126     PISSN: 13624393     EISSN: 14765624     Source Type: Journal    
DOI: 10.1038/sc.2011.14     Document Type: Article
Times cited : (22)

References (10)
  • 1
    • 9144249779 scopus 로고    scopus 로고
    • Bladder emptying over a period of 10-45 years after a traumatic spinal cord injury
    • DOI 10.1038/sj.sc.3101637
    • Hansen RB, Biering Sorensen F, Kristensen JK. Bladder emptying over a period of 10-45 years after a traumatic spinal cord injury Spinal Cord 2004; 42: 631-637 (Pubitemid 39545954)
    • (2004) Spinal Cord , vol.42 , Issue.11 , pp. 631-637
    • Hansen, R.B.1    Biering-Sorensen, F.2    Kristensen, J.K.3
  • 3
    • 21244501838 scopus 로고    scopus 로고
    • CEN European Committee for Standardization. CEN European Committee for Standardization: Brussels
    • CEN European Committee for Standardization. Sterile Urethral Catheters for Single Use. CEN European Committee for Standardization: Brussels, 1997
    • (1997) Sterile Urethral Catheters for Single Use
  • 7
    • 0027971971 scopus 로고
    • The accuracy of portable ultrasound scanning in the measurement of residual urine volume
    • Coombes GM, Millard RJ. The accuracy of portable ultrasound scanning in the measurement of residual urine volume. J Urol 1994; 152: 2083-2085 (Pubitemid 24354736)
    • (1994) Journal of Urology , vol.152 , Issue.6 , pp. 2083-2085
    • Coombes, G.M.1    Millard, R.J.2
  • 8
    • 0347359308 scopus 로고    scopus 로고
    • The accuracy of ultrasonic estimation of bladder volume: A comparison of portable and stationary equipment
    • Huang YH, Bih LI, Chen SL, Tsai SJ, Teng CH. The accuracy of ultrasonic estimation of bladder volume: A comparison of portable and stationary equipment. Arch Phys Med Rehabil 2004; 85: 138-141
    • (2004) Arch Phys Med Rehabil , vol.85 , pp. 138-141
    • Huang, Y.H.1    Bih, L.I.2    Chen, S.L.3    Tsai, S.J.4    Teng, C.H.5
  • 9
    • 34250016481 scopus 로고    scopus 로고
    • Accuracy and precision of a new portable ultrasound scanner, the BME-150A, in residual urine volume measurement: A comparison with the BladderScan BVI 3000
    • DOI 10.1007/s00192-006-0219-2
    • Choe JH, Lee JY, Lee KS. Accuracy and precision of a new portable ultrasound scanner, the BME-150A, in residual urine volume measurement: A comparison with the BladderScan BVI 3000 Int Urogynecol J Pelvic Floor Dysfunct 2007; 18: 641-644 (Pubitemid 46881712)
    • (2007) International Urogynecology Journal and Pelvic Floor Dysfunction , vol.18 , Issue.6 , pp. 641-644
    • Choe, J.H.1    Lee, J.Y.2    Lee, K.-S.3
  • 10
    • 0036714220 scopus 로고    scopus 로고
    • Intermittent catheterization: Which is the optimal technique?
    • Wyndeale J. Intermittent catheterization: Which is the optimal technique? Spinal Cord 2002; 40: 432-437
    • (2002) Spinal Cord , vol.40 , pp. 432-437
    • Wyndeale, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.