메뉴 건너뛰기




Volumn 101, Issue 2, 2011, Pages 140-143

Rapid urinary output normalization method using specific gravity

Author keywords

bioassay; dosimetry; emergencies, radiobiological; excretion, urinary

Indexed keywords

RADIOISOTOPE;

EID: 79959896119     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/HP.0b013e318213be69     Document Type: Article
Times cited : (5)

References (9)
  • 1
    • 0021916410 scopus 로고
    • Reliability of urinary creatinine as a parameter used to adjust values of urinary biological indicators
    • DOI 10.1007/BF00378371
    • Alessio L, Berlin A, Dell'Orto, Toffoletto F, Ghezzi I. Reliability of urinary creatinine as a parameter used to adjust values of urinary biological indicators. Int Arch Occup Environ Health 55:99-106; 1985. (Pubitemid 15141233)
    • (1985) International Archives of Occupational and Environmental Health , vol.55 , Issue.2 , pp. 99-106
    • Alessio, L.1    Berlin, A.2    Dell'Orto, A.3
  • 2
    • 0027496681 scopus 로고
    • Interpretation of urine results used to assess chemical exposure with emphasis on creatinine adjustments: A review
    • Boeniger MF, Lowry LK, Rosenburg J. Interpretation of urine results used to assess chemical exposure with emphasis on creatinine adjustments: A review. Am Ind Hyg Assoc J 54:615-627; 1993. (Pubitemid 23294955)
    • (1993) American Industrial Hygiene Association Journal , vol.54 , Issue.10 , pp. 615-627
    • Boeniger, M.F.1    Lowry, L.K.2    Rosenberg, J.3
  • 3
    • 79959876838 scopus 로고    scopus 로고
    • Internal technical report. Chalk River Laboratories: Atomic Energy of Canada Limited
    • Dai X. The specific gravity test for urine. Internal technical report. Chalk River Laboratories: Atomic Energy of Canada Limited; 2010.
    • (2010) The Specific Gravity Test for Urine
    • Dai, X.1
  • 4
    • 0028280442 scopus 로고
    • Replacing creatinine measurements with specific gravity values to adjust urine cotinine concentrations
    • Haddow JE, Knight GJ, Palomaki GE, Neveux LM, Chilmonczyk BA. Replacing creatinine measurements with specific gravity values to adjust urine cotinine concentrations. Clin Chem 40:562-564; 1994. (Pubitemid 24116103)
    • (1994) Clinical Chemistry , vol.40 , Issue.4 , pp. 562-564
    • Haddow, J.E.1    Knight, G.J.2    Palomaki, G.E.3    Neveux, L.M.4    Chilmonczyk, B.A.5
  • 5
    • 0003588622 scopus 로고    scopus 로고
    • International Atomic Energy Agency, Vienna: IAEA; IAEA Safety Standards Series, Safety Guide No. RS-G-1.2
    • International Atomic Energy Agency. Assessment of occupational exposure due to intakes of radionuclides. Vienna: IAEA; IAEA Safety Standards Series, Safety Guide No. RS-G-1.2; 1999.
    • (1999) Assessment of Occupational Exposure Due to Intakes of Radionuclides
  • 6
    • 79959880788 scopus 로고
    • International Commission on Radiological Protection. Recommendations of the International Commission on Radiological Protection. Oxford: Pergamon Press; ICRP Publication 10
    • International Commission on Radiological Protection. Recommendations of the International Commission on Radiological Protection. Oxford: Pergamon Press; ICRP Publication 10; 1968.
    • (1968)
  • 8
    • 2142772559 scopus 로고    scopus 로고
    • Comparison of specific gravity and creatinine for normalizing urinary reproductive hormone concentrations
    • DOI 10.1373/clinchem.2004.032292
    • Miller RC, Brindle E, Holman DJ, Shofer J, Klein NA, Soules MR, O'Connor KA. Comparison of specific gravity and creatinine for normalizing urinary reproductive hormone concentrations. Clin Chem 50:924 -932; 2004. (Pubitemid 38543672)
    • (2004) Clinical Chemistry , vol.50 , Issue.5 , pp. 924-932
    • Miller, R.C.1    Brindle, E.2    Holman, D.J.3    Shofer, J.4    Klein, N.A.5    Soules, M.R.6    O'Connor, K.A.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.