1
-
-
33845465166
-
A demographic analysis of vertical root fractures
-
DOI 10.1016/j.joen.2006.07.008, PII S0099239906006789
-
Cohen S, Berman LH, Blanco L, Bakland L, Kim JS. A demographic analysis of vertical root fractures. J Endod 2006;32:1160-1163. (Pubitemid 44895554)
-
(2006)
Journal of Endodontics
, vol.32
, Issue.12
, pp. 1160-1163
-
-
Cohen, S.1
Berman, L.H.2
Blanco, L.3
Bakland, L.4
Kim, J.S.5
-
2
-
-
0032926758
-
Dental vertical root fractures: Value of CT in detection
-
Youssefzadeh S, Gahleitner A, Dorffner R, Bernhart T, Kainberger FM. Dental vertical root fractures: value of CT in detection. Radiology 1999;210:545-549. (Pubitemid 29055327)
-
(1999)
Radiology
, vol.210
, Issue.2
, pp. 545-549
-
-
Youssefzadeh, S.1
Gahleitner, A.2
Dorffner, R.3
Bernhart, T.4
Kainberger, F.M.5
-
3
-
-
0020806439
-
Diagnosis and treatment of vertical root fractures
-
Pitts DL, Natkin E. Diagnosis and treatment of vertical root fractures. J Endod 1983;9:338-346.
-
(1983)
J Endod
, vol.9
, pp. 338-346
-
-
Pitts, D.L.1
Natkin, E.2
-
4
-
-
84984507909
-
Root fractures due to corrosion
-
Rud J, Omnell KA. Root fractures due to corrosion. Scand J Dent Res 1970;78:397-403.
-
(1970)
Scand J Dent Res
, vol.78
, pp. 397-403
-
-
Rud, J.1
Omnell, K.A.2
-
5
-
-
34247475785
-
The 3DX multi image micro-CT device in clinical dental practice
-
DOI 10.1259/dmfr/30358216
-
Suomalainen AK, Salo A, Robinson S, Peltola JS. The 3DX multi image micro-CT device in clinical dental practice. Dentomaxillofac Radiol 2007;36:80-85. (Pubitemid 46663632)
-
(2007)
Dentomaxillofacial Radiology
, vol.36
, Issue.2
, pp. 80-85
-
-
Suomalainen, A.K.1
Salo, A.2
Robinson, S.3
Peltola, J.S.4
-
6
-
-
33947683387
-
Reproducibility and accuracy of measuring unerupted teeth using limited cone beam X-ray CT
-
DOI 10.1259/dmfr/65418489
-
Saskabe J, Kuroki Y, Fujimaki S, Nakajima I, Honda K. Reproducibility and accuracy of measuring unerupted teeth using limited cone beam X-ray CT. Dentomaxillofac Radiol 2007;36:2-6. (Pubitemid 46490721)
-
(2007)
Dentomaxillofacial Radiology
, vol.36
, Issue.1
, pp. 2-6
-
-
Sakabe, J.1
Kuroki, Y.2
Fujimaki, S.3
Nakajima, I.4
Honda, K.5
-
8
-
-
28944453889
-
Three-dimensional, non-destructive visualization of vertical root fractures using flat panel volume detector computer tomography: An ex vivo in vitro case report
-
DOI 10.1111/j.1365-2591.2005.01033.x
-
Hannig C, Dullin C, Hülsmann M, Heidrict G. Three-dimensional, non-destructive visualization of vertical root fractures using flat panel volume detector computer tomography: an ex vivo in vitro case report. Int Endod J 2005;38:904-913. (Pubitemid 41784507)
-
(2005)
International Endodontic Journal
, vol.38
, Issue.12
, pp. 904-913
-
-
Hannig, C.1
Dullin, C.2
Hulsmann, M.3
Heidrich, G.4
-
9
-
-
65349107985
-
Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan
-
Hassan B, Elissavet M, Ozok AR, van der Stelt P, Wesselink PR. Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan. J Endod 2009;35:719-722.
-
(2009)
J Endod
, vol.35
, pp. 719-722
-
-
Hassan, B.1
Elissavet, M.2
Ozok, A.R.3
Van Der Stelt, P.4
Wesselink, P.R.5
-
10
-
-
0033154415
-
An evaluation of endodontically treated vertically fractured teeth
-
Tamse A, Fuss Z, Lustig J, Kaplavi J. An evaluation of endodontically treated vertically fractured teeth. J Endod 1999;25:506-508.
-
(1999)
J Endod
, vol.25
, pp. 506-508
-
-
Tamse, A.1
Fuss, Z.2
Lustig, J.3
Kaplavi, J.4
-
11
-
-
0032175744
-
Vertical root fracture in nonendodontically treated teeth - A clinical report of 64 cases in Chinese patients
-
Chan CP, Tseng SC, Lin CP, Huang CC, Tsai TP, Chen CC. Vertical root fracture in nonendodontically treated teeth - a clinical report of 64 cases in Chinese patients. J Endod 1998;10:678-681. (Pubitemid 128704273)
-
(1998)
Journal of Endodontics
, vol.24
, Issue.10
, pp. 678-681
-
-
Chan, C.-P.1
Tseng, S.-C.2
Lin, C.-P.3
Huang, C.-C.4
Tsai, T.-P.5
Chen, C.C.6
-
12
-
-
0033111299
-
Vertical root fracture in endodontically versus nonendodontically treated teeth - A survey of 315 cases in Chinese patients
-
Chan CP, Lin CP, Tseng SC, Jeng JH. Vertical root fracture in endodontically versus nonendodontically treated teeth - a survey of 315 cases in Chinese patients. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1999;87:504-507.
-
(1999)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.87
, pp. 504-507
-
-
Chan, C.P.1
Lin, C.P.2
Tseng, S.C.3
Jeng, J.H.4
-
14
-
-
0024098715
-
Iatrogenic vertical root fractures in endodontically treated teeth
-
Tamse A. Iatrogenic vertical root fractures in endodontically treated teeth. Endod Dent Traumatol 1988;4:190-196.
-
(1988)
Endod Dent Traumatol
, vol.4
, pp. 190-196
-
-
Tamse, A.1
-
15
-
-
0029315572
-
Vertical root fracture in nonendodontically treated teeth
-
Yang SF, Rivera EM, Walton RE. Vertical root fracture in nonendodontically treated teeth. J Endod 1995;21:337-339.
-
(1995)
J Endod
, vol.21
, pp. 337-339
-
-
Yang, S.F.1
Rivera, E.M.2
Walton, R.E.3
-
16
-
-
0031565385
-
Fatigue root fracture: A spontaneous root fracture in nonendodontically treated teeth
-
Yeh CJ. Fatigue root fracture: a spontaneous root fracture in nonendodontically treated teeth. Br Dent J 1997;182:261-266.
-
(1997)
Br Dent J
, vol.182
, pp. 261-266
-
-
Yeh, C.J.1
-
17
-
-
0035287365
-
Root fracture detection: A comparison of direct digital radiography with conventional radiography
-
Kositbowornchai S, Nuansakul R, Sikram S, Sinahawattana S, Saengmontri S. Root fracture detection: a comparison of direct digital radiography with conventional radiography. Dentomaxillofac Radiol 2001;30:106-109. (Pubitemid 33695394)
-
(2001)
Dentomaxillofacial Radiology
, vol.30
, Issue.2
, pp. 106-109
-
-
Kositbowornchai, S.1
Nuansakul, R.2
Sikram, S.3
Sinahawattana, S.4
Saengmontri, S.5
-
18
-
-
45949111844
-
Comparison of digital with conventional radiography in detection of vertical root fractures in endodontically treated maxillary premolars: An ex vivo study
-
Tsesis I, Kamburoǧlu K, Katz A, Tamse A, Kaffe I, Kfir A. Comparison of digital with conventional radiography in detection of vertical root fractures in endodontically treated maxillary premolars: an ex vivo study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;106:124-128.
-
(2008)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.106
, pp. 124-128
-
-
Tsesis, I.1
Kamburoǧlu, K.2
Katz, A.3
Tamse, A.4
Kaffe, I.5
Kfir, A.6
-
19
-
-
67650466015
-
Use of cone-beam volumetric tomography in the diagnosis of root fractures
-
Bernardes RA, de Moraes IG, Duarte MA, Azevedo BC, Azevedo JR, Bramante MB. Use of cone-beam volumetric tomography in the diagnosis of root fractures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;108:270-277.
-
(2009)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.108
, pp. 270-277
-
-
Bernardes, R.A.1
De Moraes, I.G.2
Duarte, M.A.3
Azevedo, B.C.4
Azevedo, J.R.5
Bramante, M.B.6
-
20
-
-
34247383567
-
In vitro perception of low-contrast features in digital, film, and digitized dental radiographs: A receiver operating characteristic analysis
-
Grassl U, Schulze RKW. In vitro perception of low-contrast features in digital, film, and digitized dental radiographs: A receiver operating characteristic analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007;103:694-701.
-
(2007)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.103
, pp. 694-701
-
-
Grassl, U.1
Schulze, R.K.W.2
-
22
-
-
33846826893
-
Reducing metal artifacts in cone-beam CT images by preprocessing projection data
-
DOI 10.1016/j.ijrobp.2006.09.045, PII S0360301606032081
-
Zhang Y, Zhang L, Zhu X, Lee A, Chamber M, Dong L. Reducing metal artifacts in cone-beam CT images by preprocessing projection data. Int J Radiat Oncol Biol Phys 2007;67:924-932. (Pubitemid 46215876)
-
(2007)
International Journal of Radiation Oncology Biology Physics
, vol.67
, Issue.3
, pp. 924-932
-
-
Zhang, Y.1
Zhang, L.2
Zhu, X.R.3
Lee, A.K.4
Chambers, M.5
Dong, L.6
-
23
-
-
48649089199
-
Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view
-
Hirsch E, Wolf U, Heinicke F, Silva MAG. Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view. Dentomaxillofac Radiol 2008;37:268-273.
-
(2008)
Dentomaxillofac Radiol
, vol.37
, pp. 268-273
-
-
Hirsch, E.1
Wolf, U.2
Heinicke, F.3
Silva, M.A.G.4
|