메뉴 건너뛰기




Volumn 44, Issue 7, 2011, Pages 583-588

Remote corrosion monitoring of the RC structures using the electrochemical wireless energy-harvesting sensors and networks

Author keywords

Corrosion monitoring; Electrochemical; Energy harvesting; RC structures; Wireless sensor

Indexed keywords

ACTIVE MONITORING; CORROSION MONITORING; CORROSION PROCESS; ELECTROCHEMICAL; ELECTROCHEMICAL REACTIONS; PASSIVE MONITORING; RC STRUCTURE; RELEASED ENERGY; SENSOR MOTES; STEEL BARS; WIRELESS SENSOR;

EID: 79959840381     PISSN: 09638695     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ndteint.2011.06.007     Document Type: Article
Times cited : (49)

References (42)
  • 2
    • 76949108447 scopus 로고    scopus 로고
    • 4): A possible candidate material as reference electrode for corrosion monitoring of steel in concrete environments
    • 4): a possible candidate material as reference electrode for corrosion monitoring of steel in concrete environments Sensors and Actuators B: Chemical 145 1 2010 225 231
    • (2010) Sensors and Actuators B: Chemical , vol.145 , Issue.1 , pp. 225-231
    • Muralidharan, S.1    Saraswathy, V.2    Berchmans, L.J.3
  • 4
    • 33845602024 scopus 로고    scopus 로고
    • Application of steel thin film electrical resistance sensor for in situ corrosion monitoring
    • DOI 10.1016/j.snb.2006.02.029, PII S0925400506001328
    • SeonYeob Li, Young-Geun Kim, and Sungwon Jung Application of steel thin film electrical resistance sensor for in situ corrosion monitoring Sensors and Actuators B: Chemical 120 2 2007 368 377 (Pubitemid 44959794)
    • (2007) Sensors and Actuators, B: Chemical , vol.120 , Issue.2 , pp. 368-377
    • Li, S.1    Kim, Y.-G.2    Jung, S.3    Song, H.-S.4    Lee, S.-M.5
  • 6
    • 77951566656 scopus 로고    scopus 로고
    • Structural health monitoring in mainland China: Review and future trends
    • Jinping Ou, and Hui Li Structural health monitoring in mainland China: review and future trends Structural Health Monitoring 9 2010 219 231
    • (2010) Structural Health Monitoring , vol.9 , pp. 219-231
    • Ou, J.1    Li, H.2
  • 7
    • 20844433900 scopus 로고    scopus 로고
    • Structural health monitoring of underground facilities - Technological issues and challenges
    • DOI 10.1016/j.tust.2005.03.003, PII S0886779805000234
    • S. Bhalla, Y.W. Yang, J. Zhao, and C.K. Soh Structural health monitoring of underground facilities - technological issues and challenges Tunnel Underground Space Technology 20 5 2005 487 500 (Pubitemid 40864783)
    • (2005) Tunnelling and Underground Space Technology , vol.20 , Issue.5 , pp. 487-500
    • Bhalla, S.1    Yang, Y.W.2    Zhao, J.3    Soh, C.K.4
  • 8
    • 60449089512 scopus 로고    scopus 로고
    • Structural health monitoring - What is the prescription?
    • Achenbach Jan D. Structural health monitoring - What is the prescription? Mechanics Research Communications 36 2009 137 142
    • (2009) Mechanics Research Communications , vol.36 , pp. 137-142
    • Jan, D.A.1
  • 9
    • 30344431793 scopus 로고    scopus 로고
    • Performance analysis of all-fiber polarimetric strain sensor for composites structural health monitoring
    • DOI 10.1016/j.ndteint.2005.09.003, PII S0963869505001477
    • Gopalkrishna Hegde, and Anand Asundi Performance analysis of all-fiber polarimetric strain sensor for composites structural health monitoring NDT and E International 39 2006 320 327 (Pubitemid 43061173)
    • (2006) NDT and E International , vol.39 , Issue.4 , pp. 320-327
    • Hegde, G.1    Asundi, A.2
  • 10
    • 68549140018 scopus 로고    scopus 로고
    • Applications of optical fibre Bragg gratings sensing technology-based smart stay cables
    • H. Li, J.P. Ou, and Z. Zhou Applications of optical fibre Bragg gratings sensing technology-based smart stay cables Optics and Lasers in Engineering 47 10 2009 1077 1084
    • (2009) Optics and Lasers in Engineering , vol.47 , Issue.10 , pp. 1077-1084
    • Li, H.1    Ou, J.P.2    Zhou, Z.3
  • 12
    • 49649105148 scopus 로고    scopus 로고
    • Development of a wireless stress/strain measurement system integrated with pressure-sensitive nickel powder-filled cement-based sensors
    • B.G. Han, Y. Yu, B.Z. Han, and J.P. Ou Development of a wireless stress/strain measurement system integrated with pressure-sensitive nickel powder-filled cement-based sensors Sensors and Actuators: A physical 147 2 2008 536 543
    • (2008) Sensors and Actuators: A Physical , vol.147 , Issue.2 , pp. 536-543
    • Han, B.G.1    Yu, Y.2    Han, B.Z.3    Ou, J.P.4
  • 13
    • 58449092633 scopus 로고    scopus 로고
    • Piezoresistive cement-based strain sensors and self-sensing concrete components
    • J.P. Ou, and B.G. Han Piezoresistive cement-based strain sensors and self-sensing concrete components Journal of Intelligent Material Systems and Structures 20 3 2009 329 336
    • (2009) Journal of Intelligent Material Systems and Structures , vol.20 , Issue.3 , pp. 329-336
    • Ou, J.P.1    Han, B.G.2
  • 14
    • 44149115168 scopus 로고    scopus 로고
    • Electrical property of cement-based composites filled with carbon black under long-term wet and loading condition
    • H. Li, H.G. Xiao, and J.P. Ou Electrical property of cement-based composites filled with carbon black under long-term wet and loading condition Composites Science and Technology 68 9 2008 2114 2119
    • (2008) Composites Science and Technology , vol.68 , Issue.9 , pp. 2114-2119
    • Li, H.1    Xiao, H.G.2    Ou, J.P.3
  • 16
    • 79151482658 scopus 로고    scopus 로고
    • Effective monitoring of corrosion in reinforcing steel in concrete constructions by a multifunctional sensor
    • Shi-Gang Dong, Chang-Jian Lin, Rong-Gang Hu, Lan-Qiang Li, and Rong-Gui Du Effective monitoring of corrosion in reinforcing steel in concrete constructions by a multifunctional sensor Electrochimica Acta 56 2011 1881 1888
    • (2011) Electrochimica Acta , vol.56 , pp. 1881-1888
    • Dong, S.-G.1    Lin, C.-J.2    Hu, R.-G.3    Li, L.-Q.4    Du, R.-G.5
  • 18
    • 0037401937 scopus 로고    scopus 로고
    • Reinforcement corrosion in concrete structures, its monitoring and service life prediction - A review
    • S Ahmad Reinforcement corrosion in concrete structures, its monitoring and service life prediction - a review Cement and Concrete Composites 25 2003 459 471
    • (2003) Cement and Concrete Composites , vol.25 , pp. 459-471
    • Ahmad, S.1
  • 19
    • 80052028097 scopus 로고    scopus 로고
    • Calibration of the electrochemical methods for the corrosion rate measurement of steel in concrete
    • Tang Luping Calibration of the electrochemical methods for the corrosion rate measurement of steel in concrete NORDTEST Project No.1531-01 2007
    • (2007) NORDTEST Project No.1531-01
    • Luping, T.1
  • 21
    • 54349092599 scopus 로고    scopus 로고
    • Integration of durability with structural design: An optimal life cycle cost based design procedure for reinforced concrete structures
    • H Narasimhan, and M.Y.L. Chew Integration of durability with structural design: an optimal life cycle cost based design procedure for reinforced concrete structures Construction and Building Materials 23 2009 918 929
    • (2009) Construction and Building Materials , vol.23 , pp. 918-929
    • Narasimhan, H.1    Chew, M.Y.L.2
  • 23
    • 11344292645 scopus 로고    scopus 로고
    • Unification of the deterministic and statistical approaches for predicting localized corrosion damage. I. Theoretical foundation
    • DOI 10.1016/j.corsci.2004.03.014, PII S0010938X04000782
    • G Engelhardt, and D Macdonald Unification of the deterministic and statistical approaches for predicting localized corrosion damage. I Theoretical foundation Corrosion Science 46 2004 2755 2780 (Pubitemid 40077354)
    • (2004) Corrosion Science , vol.46 , Issue.11 , pp. 2755-2780
    • Engelhardt, G.1    Macdonald, D.D.2
  • 24
  • 25
    • 34548142774 scopus 로고    scopus 로고
    • Equivalent circuit for modeling the steelconcrete interface. I. Experimental evidence and theoretical predictions
    • V Feliu, J.A Gonzalez, and C Andrade Equivalent circuit for modeling the steelconcrete interface. I. Experimental evidence and theoretical predictions Corrosion Science 39 1998 864 882
    • (1998) Corrosion Science , vol.39 , pp. 864-882
    • Feliu, V.1    Gonzalez, J.A.2    Andrade, C.3
  • 26
    • 0032101389 scopus 로고    scopus 로고
    • Equivalent circuit for modelling the steel-concrete interface. II. Complications in applying the Stern-Geary equation to corrosion rate determinations
    • DOI 10.1016/S0010-938X(98)00037-7, PII S0010938X98000377
    • V Feliu, J.A Gonzalez, and C Andrade Equivalent circuit for modeling the steelconcrete interface. II. Complications in applying the SternGeary equation to corrosion rate determinations Corrosion Science 40 1998 995 1006 (Pubitemid 28490746)
    • (1998) Corrosion Science , vol.40 , Issue.6 , pp. 995-1006
    • Feliu, V.1    Gonzalez, J.A.2    Andrade, C.3    Feliu, S.4
  • 27
    • 8344250219 scopus 로고    scopus 로고
    • Considerations on reproducibility of potential and corrosion rate measurements in reinforced concrete
    • DOI 10.1016/j.corsci.2004.02.003, PII S0010938X04000496
    • J.A Gonzalez, J.M Miranda, and S Feliu Considerations on reproducibility of potential and corrosion rate measurements in reinforced concrete Corrosion Science 46 2004 2467 2485 (Pubitemid 39483755)
    • (2004) Corrosion Science , vol.46 , Issue.10 , pp. 2467-2485
    • Gonzalez, J.A.1    Miranda, J.M.2    Feliu, S.3
  • 28
    • 67651152563 scopus 로고    scopus 로고
    • Examples of reinforcement corrosion monitoring by embedded sensors in concrete structures
    • I. Martínez, and C. Andrade Examples of reinforcement corrosion monitoring by embedded sensors in concrete structures Cement and Concrete Composites 31 2009 545 554
    • (2009) Cement and Concrete Composites , vol.31 , pp. 545-554
    • Martínez, I.1    Andrade, C.2
  • 30
    • 0035241901 scopus 로고    scopus 로고
    • Concerning trend removal in electrochemical noise measurements
    • DOI 10.1016/S0010-938X(00)00064-0, PII S0010938X00000640
    • F Mansfeld, Z Sun, and C.H Hsu Concerning trend removal in electrochemical noise measurements Corrosion Science 43 2001 341 352 (Pubitemid 32170054)
    • (2001) Corrosion Science , vol.43 , Issue.2 , pp. 341-352
    • Mansfeld, F.1    Sun, Z.2    Hsu, C.H.3    Ngiub, A.4
  • 31
    • 33947184826 scopus 로고    scopus 로고
    • Use of the time constant to detect corrosion speed in reinforced concrete structures
    • DOI 10.1016/j.cemconcomp.2006.12.007, PII S0958946507000066
    • N. Birbilis, and L.J. Holloway Use of the time constant to detect corrosion speed in reinforced concrete structures Cement and Concrete Composites 29 2007 330 336 (Pubitemid 46401241)
    • (2007) Cement and Concrete Composites , vol.29 , Issue.4 , pp. 330-336
    • Birbilis, N.1    Holloway, L.J.2
  • 33
    • 33748059566 scopus 로고    scopus 로고
    • Fractal characteristic analysis of electrochemical noise with wavelet transform
    • DOI 10.1016/j.corsci.2005.06.001, PII S0010938X05001526
    • X.F Liu, H.G Wang, and H.C Gu Fractal characteristic analysis of electrochemical noise with wavelet transform Corrosion Science 48 2006 1337 1367 (Pubitemid 44294615)
    • (2006) Corrosion Science , vol.48 , Issue.6 , pp. 1337-1367
    • Liu, X.F.1    Wang, H.G.2    Gu, H.C.3
  • 34
    • 78149467756 scopus 로고    scopus 로고
    • Multifractal modeling of electrochemical noise in corrosion of carbon steel
    • S.V. Muniandy, W.X. Chew, and C.S. Kan Multifractal modeling of electrochemical noise in corrosion of carbon steel Corrosion Science 53 1 2011 188 200
    • (2011) Corrosion Science , vol.53 , Issue.1 , pp. 188-200
    • Muniandy, S.V.1    Chew, W.X.2    Kan, C.S.3
  • 37
    • 48049090253 scopus 로고    scopus 로고
    • Evaluation of embeddable potential sensor for corrosion monitoring in concrete structures
    • S. Muralidharan, V. Saraswathy, and A. Madhavamayandi Evaluation of embeddable potential sensor for corrosion monitoring in concrete structures Electrochimica Acta 53 2008 7248 7254
    • (2008) Electrochimica Acta , vol.53 , pp. 7248-7254
    • Muralidharan, S.1    Saraswathy, V.2    Madhavamayandi, A.3
  • 38
    • 34247239291 scopus 로고    scopus 로고
    • EverLast: Long-life supercapacitor-operated wireless sensor node
    • Simjee F, Hou P. EverLast: long-life supercapacitor-operated wireless sensor node. In: ISLPED; 2006. p. 17985
    • (2006) ISLPED , pp. 17985
    • Simjee, F.1    Hou, P.2
  • 39
    • 33646950065 scopus 로고    scopus 로고
    • Perpetual environmentally powered sensor networks
    • Jiang X, Polastre J, Culler D. Perpetual environmentally powered sensor networks. In: IPSN; 2005.
    • (2005) IPSN
    • Jiang, X.1    Polastre, J.2    Culler, D.3
  • 41
    • 80052030712 scopus 로고    scopus 로고
    • 〈 http://www.xbow.com 〉


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.