메뉴 건너뛰기




Volumn 35, Issue 11, 2011, Pages 33-38

Reactive power optimization in distribution network considering reactive power regulation capability of DFIG wind farm

Author keywords

Particle swarm optimization algorithm; Reactive power capability limits; Reactive power optimization; Wind farm; Wind turbine driven doubly fed induction generator

Indexed keywords

ACTIVE POWER LOSS; DISTRIBUTION NETWORK; DISTRIBUTION SYSTEMS; DOUBLY-FED INDUCTION GENERATOR; NODE VOLTAGES; OBJECTIVE FUNCTIONS; OPTIMIZATION PROBLEMS; PARTICLE SWARM OPTIMIZATION ALGORITHM; REACTIVE POWER CAPABILITY; REACTIVE POWER CAPABILITY LIMITS; REACTIVE POWER CAPACITY; REACTIVE POWER OPTIMIZATION; REACTIVE POWER REGULATION; TEST CASE; WIND FARM; WIND VELOCITIES;

EID: 79959775493     PISSN: 10001026     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (51)

References (15)
  • 1
    • 0034156385 scopus 로고    scopus 로고
    • Reliability model of wind power plants and its application
    • CHEN Shuyong, DAI Huizhu, BAI Xiaomin, et al. Reliability model of wind power plants and its application[J]. Proceedings of the CSEE, 2000, 20(3): 26-29.
    • (2000) Proceedings of the CSEE , vol.20 , Issue.3 , pp. 26-29
    • Chen, S.1    Dai, H.2    Bai, X.3
  • 4
    • 34249280256 scopus 로고    scopus 로고
    • Reactive power analysis and control of doubly fed induction generator wind far
    • LANG Yongqiang, ZHANG Xueguang, XU Dianguo, et al. Reactive power analysis and control of doubly fed induction generator wind farm[J]. Proceedings of the CSEE, 2007, 27(9): 77-82.
    • (2007) Proceedings of the CSEE , vol.27 , Issue.9 , pp. 77-82
    • Lang, Y.1    Zhang, X.2    Xu, D.3
  • 5
    • 0345411899 scopus 로고    scopus 로고
    • Reactive power control of wind farms for voltage control applications
    • TAPIA A, TAPIA G, OSTOLAZA J X. Reactive power control of wind farms for voltage control applications[J]. Renewable Energy, 2004, 29(3): 377-392.
    • (2004) Renewable Energy , vol.29 , Issue.3 , pp. 377-392
    • Tapia, A.1    Tapia, G.2    Ostolaza, J.X.3
  • 6
    • 34249798182 scopus 로고    scopus 로고
    • Proportional-integral regulator-based approach to wind farm reactive power management for secondary voltage control
    • TAPIA G, TAPIA A, OSTOLAZA J X. Proportional-integral regulator-based approach to wind farm reactive power management for secondary voltage control[J]. IEEE Trans on Energy Conversion, 2007, 22(2): 448-459.
    • (2007) IEEE Trans on Energy Conversion , vol.22 , Issue.2 , pp. 448-459
    • Tapia, G.1    Tapia, A.2    Ostolaza, J.X.3
  • 7
    • 61949116242 scopus 로고    scopus 로고
    • A voltage control strategy for wind farms using doubly fed induction generator wind turbines
    • CAO Jun, ZHANG Ronglin, LIN Guoqing, et al. A voltage control strategy for wind farms using doubly fed induction generator wind turbines[J]. Automation of Electric Power Systems, 2009, 33(4): 87-91.
    • (2009) Automation of Electric Power Systems , vol.33 , Issue.4 , pp. 87-91
    • Cao, J.1    Zhang, R.2    Lin, G.3
  • 8
    • 0037171401 scopus 로고    scopus 로고
    • Time interval based control strategy of reactive power optimization in distribution networks
    • HU Zechun, WANG Xifan. Time interval based control strategy of reactive power optimization in distribution networks[J]. Automation of Electric Power Systems, 2002, 26(6): 45-49.
    • (2002) Automation of Electric Power Systems , vol.26 , Issue.6 , pp. 45-49
    • Hu, Z.1    Wang, X.2
  • 9
    • 2442689446 scopus 로고    scopus 로고
    • Dynamic reactive-power optimization algorithm incorporating action number constraints of control devices
    • LIU Mingbo, ZHU Chunming, QIAN Kangling, et al. Dynamic reactive-power optimization algorithm incorporating action number constraints of control devices[J]. Proceedings of the CSEE, 2004, 24(3): 34-40.
    • (2004) Proceedings of the CSEE , vol.24 , Issue.3 , pp. 34-40
    • Liu, M.1    Zhu, C.2    Qian, K.3
  • 10
    • 45449110443 scopus 로고    scopus 로고
    • Heuristic strategy for dynamic reactive power optimization incorporating action time constraints between adjacent time intervals
    • YAN Wei, TIAN Tian, ZHANG Haibing. Heuristic strategy for dynamic reactive power optimization incorporating action time constraints between adjacent time intervals[J]. Automation of Electric Power Systems, 2008, 32(10): 71-76.
    • (2008) Automation of Electric Power Systems , vol.32 , Issue.10 , pp. 71-76
    • Yan, W.1    Tian, T.2    Zhang, H.3
  • 12
    • 79959785085 scopus 로고    scopus 로고
    • Chinese source
    • 2003.
    • (2003)
  • 15
    • 34250833384 scopus 로고
    • Network reconfiguration in distribution systems for loss reduction and load balancing
    • BARAN M E, WU F F. Network reconfiguration in distribution systems for loss reduction and load balancing[J]. IEEE Trans on Power Delivery, 1989, 4(2): 1401-1407.
    • (1989) IEEE Trans on Power Delivery , vol.4 , Issue.2 , pp. 1401-1407
    • Baran, M.E.1    Wu, F.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.