메뉴 건너뛰기




Volumn 157, Issue 2, 2011, Pages 417-423

A dual K+-Na+ selective Prussian blue nanotubes sensor

Author keywords

Hexacyanoferrate; Potassium; Prussian blue; Saliva; Sensor; Sodium

Indexed keywords

ANALYTICAL SIGNALS; ARTIFICIAL SALIVA; CATHODIC PEAK; COMPETITIVE INHIBITION; DUAL SENSING; HEXACYANOFERRATES; MODEL-BASED OPC; PRUSSIAN BLUE; SALIVA; SAMPLE SOLUTION; SENSOR RESPONSE; VERSATILE METHODS;

EID: 79959676874     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.04.076     Document Type: Article
Times cited : (22)

References (25)
  • 1
    • 58349115177 scopus 로고    scopus 로고
    • Non-invasive matrices in human biomonitoring: A review
    • M. Esteban, and A. Castano Non-invasive matrices in human biomonitoring: a review Environ. Int. 35 2009 438 449
    • (2009) Environ. Int. , vol.35 , pp. 438-449
    • Esteban, M.1    Castano, A.2
  • 2
    • 1042264337 scopus 로고    scopus 로고
    • What is the optimal serum potassium level in cardiovascular patients?
    • DOI 10.1016/j.jacc.2003.06.021
    • J.E. Macdonald, and A.D. Struthers What is the optimal serum potassium level in cardiovascular patients? J. Am. Coll. Cardiol. 43 2004 155 161 (Pubitemid 38201137)
    • (2004) Journal of the American College of Cardiology , vol.43 , Issue.2 , pp. 155-161
    • Macdonald, J.E.1    Struthers, A.D.2
  • 3
    • 58349113188 scopus 로고    scopus 로고
    • Joint effects of sodium and potassium intake on subsequent cardiovascular disease: The trials of hypertension prevention follow-up study
    • N.R. Cook, E. Obarzanek, J.A. Cutler, J.E. Buring, K.M. Rexrode, S.K. Kumanyika, L.J. Appel, and P.K. Whelton Joint effects of sodium and potassium intake on subsequent cardiovascular disease: the trials of hypertension prevention follow-up study Arch. Intern. Med. 169 2009 32 40
    • (2009) Arch. Intern. Med. , vol.169 , pp. 32-40
    • Cook, N.R.1    Obarzanek, E.2    Cutler, J.A.3    Buring, J.E.4    Rexrode, K.M.5    Kumanyika, S.K.6    Appel, L.J.7    Whelton, P.K.8
  • 4
    • 59949083369 scopus 로고    scopus 로고
    • Measurement of xenobiotics in saliva: Is saliva an attractive alternative matrix? Case studies and analytical perspectives
    • R. Mullangi, S. Agrawal, and N.R. Srinivas Measurement of xenobiotics in saliva: is saliva an attractive alternative matrix? Case studies and analytical perspectives Biomed. Chromatogr. 23 2009 3 25
    • (2009) Biomed. Chromatogr. , vol.23 , pp. 3-25
    • Mullangi, R.1    Agrawal, S.2    Srinivas, N.R.3
  • 5
    • 64649098325 scopus 로고    scopus 로고
    • Ion-transfer voltammetric determination of the P-blocker propranolol in a physiological matrix at silicon membrane-based liquid vertical bar liquid microinterface arrays
    • C.J. Collins, and D.W.M. Arrigan Ion-transfer voltammetric determination of the P-blocker propranolol in a physiological matrix at silicon membrane-based liquid vertical bar liquid microinterface arrays Anal. Chem. 81 2009 2344 2349
    • (2009) Anal. Chem. , vol.81 , pp. 2344-2349
    • Collins, C.J.1    Arrigan, D.W.M.2
  • 6
    • 0030039397 scopus 로고    scopus 로고
    • Concentrations of sodium, potassium and cortisol in saliva, and self-reported chronic work stress factors
    • DOI 10.1016/0301-0511(95)05171-6
    • R.F. Burton, J.W. Hinton, E. Neilson, and G. Beastall Concentrations of sodium, potassium and cortisol in saliva, and self-reported chronic work stress factors Biol. Psychol. 42 1996 425 438 (Pubitemid 26068941)
    • (1996) Biological Psychology , vol.42 , Issue.3 , pp. 425-438
    • Burton, R.F.1    Hinton, J.W.2    Neilson, E.3    Beastall, G.4
  • 7
    • 0037949965 scopus 로고    scopus 로고
    • Churchill Livingstone Toronto
    • D.B. Ferguson Oral Bioscience 1999 Churchill Livingstone Toronto pp. 136-150
    • (1999) Oral Bioscience
    • Ferguson, D.B.1
  • 11
    • 33749254455 scopus 로고    scopus 로고
    • PVC-based membranes of N,N′-dibenzyl-1,4,10,13-tetraoxa-7,16- diazacyclooctadecane as Pb(II)-selective sensor
    • DOI 10.1016/j.snb.2006.02.019, PII S0925400506000980
    • V.K. Gupta, A.K. Jain, and P. Kumar PVC-based membranes of N,N′-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as Pb(II)-selective sensor Sens. Actuat. B: Chem. 120 2006 259 265 (Pubitemid 44486698)
    • (2006) Sensors and Actuators, B: Chemical , vol.120 , Issue.1 , pp. 259-265
    • Gupta, V.K.1    Jain, A.K.2    Kumar, P.3
  • 13
    • 0001864187 scopus 로고
    • Simultaneous determination of sodium and potassium in human urine or serum using coated-wire ion-selective electrodes based on bis(crown ether)s
    • H. Tamura, K. Kumami, K. Kimura, and T. Shono Simultaneous determination of sodium and potassium in human urine or serum using coated-wire ion-selective electrodes based on bis(crown ether)s Mikrochim. Acta 80 1983 287 296
    • (1983) Mikrochim. Acta , vol.80 , pp. 287-296
    • Tamura, H.1    Kumami, K.2    Kimura, K.3    Shono, T.4
  • 14
    • 0032129472 scopus 로고    scopus 로고
    • Analytical applications of cooperative interactions associated with charge transfer in cyanometalate electrodes: Analysis of sodium and potassium in human whole blood
    • D.R. Coon, L.J. Amos, A.B. Bocarsly, and P.A. Fitzgerald Bocarsly Analytical applications of cooperative interactions associated with charge transfer in cyanometalate electrodes: analysis of sodium and potassium in human whole blood Anal. Chem. 70 1998 3137 3145
    • (1998) Anal. Chem. , vol.70 , pp. 3137-3145
    • Coon, D.R.1    Amos, L.J.2    Bocarsly, A.B.3    Fitzgerald Bocarsly, P.A.4
  • 15
    • 0035159351 scopus 로고    scopus 로고
    • Selectivity behavior and multianalyte detection capability of voltammetric ionophore-based plasticized polymeric membrane sensors
    • S. Jadhav, and E. Bakker Selectivity behavior and multianalyte detection capability of voltammetric ionophore-based plasticized polymeric membrane sensors Anal. Chem. 73 2001 80 90
    • (2001) Anal. Chem. , vol.73 , pp. 80-90
    • Jadhav, S.1    Bakker, E.2
  • 16
    • 1842633873 scopus 로고    scopus 로고
    • Distinguishing free and total calcium with a single pulsed galvanostatic ion-selective electrode
    • A. Shvarev, and E. Bakker Distinguishing free and total calcium with a single pulsed galvanostatic ion-selective electrode Talanta 63 2004 195 200
    • (2004) Talanta , vol.63 , pp. 195-200
    • Shvarev, A.1    Bakker, E.2
  • 17
    • 33748535064 scopus 로고    scopus 로고
    • A steady-state voltammetric procedure for the determination of hydrogen ions and total acid concentration in mixtures of a strong and a weak monoprotic acid
    • DOI 10.1016/j.electacta.2006.03.072, PII S0013468606003318
    • S. Daniele, C. Bragato, and M.A. Baldo A steady-state voltammetric procedure for the determination of hydrogen ions and total acid concentration in mixtures of a strong and a weak monoprotic acid Electrochim. Acta 52 2006 54 61 (Pubitemid 44374474)
    • (2006) Electrochimica Acta , vol.52 , Issue.1 , pp. 54-61
    • Daniele, S.1    Bragato, C.2    Baldo, M.A.3
  • 18
    • 35348976759 scopus 로고    scopus 로고
    • Application of sphere cap mercury microelectrodes and scanning electrochemical microscopy (SECM) for heavy metal monitoring at solid/solution interfaces
    • S. Daniele, I. Ciani, M.A. Baldo, and C. Bragato Application of sphere cap mercury microelectrodes and scanning electrochemical microscopy (SECM) for heavy metal monitoring at solid/solution interfaces Electroanalysis 19 2007 2067 2076
    • (2007) Electroanalysis , vol.19 , pp. 2067-2076
    • Daniele, S.1    Ciani, I.2    Baldo, M.A.3    Bragato, C.4
  • 19
    • 33744986798 scopus 로고
    • Eelectrochemistry of polynuclear transition-metal cyanides - Prussian blue and its analogs
    • K. Itaya, I. Uchida, and V.D. Neff Eelectrochemistry of polynuclear transition-metal cyanides - Prussian blue and its analogs Acc. Chem. Res. 19 1986 162 168
    • (1986) Acc. Chem. Res. , vol.19 , pp. 162-168
    • Itaya, K.1    Uchida, I.2    Neff, V.D.3
  • 20
    • 0035369945 scopus 로고    scopus 로고
    • A novel potassium ion sensing based on Prussian blue thin films
    • K.C. Ho, and C.L. Lin A novel potassium ion sensing based on Prussian blue thin films Sens. Actuat. B: Chem. 76 2001 512 518
    • (2001) Sens. Actuat. B: Chem. , vol.76 , pp. 512-518
    • Ho, K.C.1    Lin, C.L.2
  • 21
    • 0025064657 scopus 로고
    • Prussian blue solid-state films and membranes as potassium ion-selective electrodes
    • DOI 10.1016/S0003-2670(00)83828-3
    • V. Krishnan, A.L. Xidis, and V.D. Neff Prussian blue solid-state films and membranes as potassium ion-selective electrodes Anal. Chim. Acta 239 1990 7 12 (Pubitemid 20365142)
    • (1990) Analytica Chimica Acta , vol.239 , Issue.1 , pp. 7-12
    • Krishnan, V.1    Xidis, A.L.2    Neff, V.D.3
  • 23
    • 70349749923 scopus 로고    scopus 로고
    • Sensitive detection of potassium ion using Prussian blue nanotube sensor
    • B.T.T. Nguyen, J.Q. Ang, and C.S. Toh Sensitive detection of potassium ion using Prussian blue nanotube sensor Electrochem. Commun. 11 2009 1861 1864
    • (2009) Electrochem. Commun. , vol.11 , pp. 1861-1864
    • Nguyen, B.T.T.1    Ang, J.Q.2    Toh, C.S.3
  • 24
    • 0345356274 scopus 로고    scopus 로고
    • Self-assembled films of Prussian blue and analogues: Structure and morphology, elemental composition, film growth, and nanosieving of ions
    • W. Jin, A. Toutianoush, M. Pyrasch, J. Schnepf, H. Gottschalk, W. Rammensee, and B. Tieke Self-assembled films of Prussian blue and analogues: structure and morphology, elemental composition, film growth, and nanosieving of ions J. Phys. Chem. B 107 2003 12062 12070
    • (2003) J. Phys. Chem. B , vol.107 , pp. 12062-12070
    • Jin, W.1    Toutianoush, A.2    Pyrasch, M.3    Schnepf, J.4    Gottschalk, H.5    Rammensee, W.6    Tieke, B.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.