메뉴 건너뛰기




Volumn 157, Issue 1, 2011, Pages 183-188

Pure and Pt-loaded gamma iron oxide as sensor for detection of sub ppm level of acetone

Author keywords

Acetone; Gas sensor; Pt loaded Fe2O3; Sonochemical synthesis

Indexed keywords

ENERGY DISPERSIVE X-RAY; GAS SENSOR; HIGH RESPONSE; NANOCRYSTALLINES; NON-INVASIVE; PT LOADING; SCANNING ELECTRON MICROSCOPES; SELECTED AREA ELECTRON DIFFRACTION; SONOCHEMICAL SYNTHESIS; SYNTHESIZED POWDER; TRANSMISSION ELECTRON MICROGRAPH; ULTRASONIC IRRADIATION;

EID: 79959671051     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.03.047     Document Type: Article
Times cited : (64)

References (16)
  • 4
    • 33750620229 scopus 로고    scopus 로고
    • 3-based gas sensors
    • DOI 10.1016/j.msea.2006.08.013, PII S0921509306017412
    • 3-based gas sensors Materials Science and Engineering A 441 2006 176 180 (Pubitemid 44689066)
    • (2006) Materials Science and Engineering A , vol.441 , Issue.1-2 , pp. 176-180
    • Jing, Z.1
  • 7
    • 33749264587 scopus 로고    scopus 로고
    • 3 by anhydrous solvent method
    • DOI 10.1016/j.matlet.2006.03.112, PII S0167577X06004174
    • 3 by anhydrous solvent method Materials Letters 60 2006 3315 3318 (Pubitemid 44485234)
    • (2006) Materials Letters , vol.60 , Issue.28 , pp. 3315-3318
    • Jing, Z.1
  • 8
    • 0014693864 scopus 로고
    • Breath-acetone and blood-sugar measurements in diabetes
    • C.N. Tassopoulos, D. Barnett, and T.R. Fraser Breath-acetone and blood-sugar measurements in diabetes Lancet 293 1969 1282 1286
    • (1969) Lancet , vol.293 , pp. 1282-1286
    • Tassopoulos, C.N.1    Barnett, D.2    Fraser, T.R.3
  • 9
    • 0036287962 scopus 로고    scopus 로고
    • Breath acetone is a reliable indicator of ketosis in adults consuming ketogenic meals
    • K.M. Veloso, S.S. Likhodi, and S.C. Cunnane Breath acetone is a reliable indicator of ketosis in adults consuming ketogenic meals American Journal of Clinical Nutrition 76 2002 65 70 (Pubitemid 34686550)
    • (2002) American Journal of Clinical Nutrition , vol.76 , Issue.1 , pp. 65-70
    • Musa-Veloso, K.1    Likhodii, S.S.2    Cunnane, S.C.3
  • 10
    • 33645835176 scopus 로고    scopus 로고
    • Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver
    • J.C. Anderson, W.J.E. Lamm, and M.P. Hlastala Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver Journal of Applied Physiology 100 2006 88 89
    • (2006) Journal of Applied Physiology , vol.100 , pp. 88-89
    • Anderson, J.C.1    Lamm, W.J.E.2    Hlastala, M.P.3
  • 11
    • 0034253311 scopus 로고    scopus 로고
    • Diagnosis of diabetes by image detection of breath using gas-sensitive laps
    • Q. Zhang, P. Wang, J. Li, and X. Gao Diagnosis of diabetes by image detection of breath using gas-sensitive laps Biosensors & Bioelectronics 15 2000 249 256
    • (2000) Biosensors & Bioelectronics , vol.15 , pp. 249-256
    • Zhang, Q.1    Wang, P.2    Li, J.3    Gao, X.4
  • 12
    • 39449112689 scopus 로고    scopus 로고
    • Detection of biomarker in breath: A step towards noninvasive diabetes monitoring
    • S. Chakraborty, D. Banerjee, I. Ray, and A. Sen Detection of biomarker in breath: a step towards noninvasive diabetes monitoring Current Science 94 2008 237 242 (Pubitemid 351270507)
    • (2008) Current Science , vol.94 , Issue.2 , pp. 237-242
    • Chakraborty, S.1    Banerjee, D.2    Ray, I.3    Sen, A.4
  • 13
    • 0027389917 scopus 로고
    • Breath acetone analyzer: Diagnostic tool to monitor dietary fat loss
    • S.K. Kundu, J.A. Bruzek, R. Nair, and A.M. Judilla Breath acetone analyzer: diagnostic tool to monitor dietary fat loss Clinical Chemistry 39 1993 87 92 (Pubitemid 23034962)
    • (1993) Clinical Chemistry , vol.39 , Issue.1 , pp. 87-92
    • Kundu, S.K.1    Bruzek, J.A.2    Nair, R.3    Judilla, A.M.4
  • 14
    • 0037773381 scopus 로고    scopus 로고
    • Current/voltage characteristics of a semiconductor metal oxide gas sensor
    • S. pitcher, J.A. Thiele, H. Ren, and J.F. Vetelino Current/voltage characteristics of a semiconductor metal oxide gas sensor Sensor and Actuators B 93 2003 454 462
    • (2003) Sensor and Actuators B , vol.93 , pp. 454-462
    • Pitcher, S.1    Thiele, J.A.2    Ren, H.3    Vetelino, J.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.