메뉴 건너뛰기




Volumn 271, Issue 7-8, 2011, Pages 1093-1102

Fretting-corrosion behavior of β titanium alloys in simulated synovial fluid

Author keywords

Biomaterials; Critical pressure; Depassivation; Repassivation

Indexed keywords

ANODIC CURRENTS; BOVINE SERUM ALBUMINS; COMBINED ACTIONS; CONTACT PRESSURES; CORROSIVE ENVIRONMENT; CRITICAL PRESSURES; DEPASSIVATION; FRETTING WEAR; FRICTION COEFFICIENTS; HANK'S BALANCED SALT SOLUTIONS; HYALURONIC ACIDS; IN-SITU; MATERIAL DEGRADATION; OPEN CIRCUIT POTENTIAL; PASSIVE LAYER; RE-PASSIVATION; SMALL DISPLACEMENT; SYNOVIAL FLUID; TI-29NB-13TA-4.6ZR; WEAR RATES; WEAR TRACKS;

EID: 79959565428     PISSN: 00431648     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.wear.2011.05.010     Document Type: Article
Times cited : (63)

References (25)
  • 1
    • 23044455858 scopus 로고    scopus 로고
    • Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution
    • Barril S., Mischler S., Landolt D. Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution. Wear 2005, 259:282-291.
    • (2005) Wear , vol.259 , pp. 282-291
    • Barril, S.1    Mischler, S.2    Landolt, D.3
  • 2
    • 77953325180 scopus 로고    scopus 로고
    • Tribocorrosion of stainless steel in sulfuric acid: identification of corrosion-wear components and effect of contact area
    • Diomidis N., Celis J.-P., Ponthiaux P., Wenger F. Tribocorrosion of stainless steel in sulfuric acid: identification of corrosion-wear components and effect of contact area. Wear 2010, 269:93-103.
    • (2010) Wear , vol.269 , pp. 93-103
    • Diomidis, N.1    Celis, J.-P.2    Ponthiaux, P.3    Wenger, F.4
  • 3
    • 2342593395 scopus 로고    scopus 로고
    • Influence of fretting regimes on the tribocorrosion behavior of Ti6Al4V in 0.9wt% sodium chloride solution
    • Barril S., Mischler S., Landolt D. Influence of fretting regimes on the tribocorrosion behavior of Ti6Al4V in 0.9wt% sodium chloride solution. Wear 2004, 256:963-972.
    • (2004) Wear , vol.256 , pp. 963-972
    • Barril, S.1    Mischler, S.2    Landolt, D.3
  • 4
    • 0024087504 scopus 로고
    • On fretting maps
    • Vingsbo O., Söderberg S. On fretting maps. Wear 1988, 126:131-147.
    • (1988) Wear , vol.126 , pp. 131-147
    • Vingsbo, O.1    Söderberg, S.2
  • 5
    • 11444255075 scopus 로고    scopus 로고
    • Titanium for hip and knee prostheses
    • Springer-Verlag, D.M. Brunette, P. Tengvall, M. Textor, P. Thomsen (Eds.)
    • Windler M., Klabunde R. Titanium for hip and knee prostheses. Titanium in Medicine 2001, 703-746. Springer-Verlag. D.M. Brunette, P. Tengvall, M. Textor, P. Thomsen (Eds.).
    • (2001) Titanium in Medicine , pp. 703-746
    • Windler, M.1    Klabunde, R.2
  • 6
    • 0038542978 scopus 로고    scopus 로고
    • Orthopedic implant fretting corrosion
    • Hallab N.J., Jacobs J.J. Orthopedic implant fretting corrosion. Corros. Rev. 2003, 21:183-213.
    • (2003) Corros. Rev. , vol.21 , pp. 183-213
    • Hallab, N.J.1    Jacobs, J.J.2
  • 7
    • 33750501962 scopus 로고    scopus 로고
    • The influence of proteins on the fretting-corrosion behaviour of a Ti6Al4V alloy
    • Hiromoto S., Mischler S. The influence of proteins on the fretting-corrosion behaviour of a Ti6Al4V alloy. Wear 2006, 261:1002-1011.
    • (2006) Wear , vol.261 , pp. 1002-1011
    • Hiromoto, S.1    Mischler, S.2
  • 8
    • 2442688104 scopus 로고    scopus 로고
    • EIS characterization of a Ti-dental implant in artificial saliva media: dissolution process of the oxide barrier
    • Marino C.E.B., Mascaro L.H. EIS characterization of a Ti-dental implant in artificial saliva media: dissolution process of the oxide barrier. J. Electroanal. Chem. 2004, 568:115-120.
    • (2004) J. Electroanal. Chem. , vol.568 , pp. 115-120
    • Marino, C.E.B.1    Mascaro, L.H.2
  • 9
    • 0037035517 scopus 로고    scopus 로고
    • Electrochemical characterisation of passive films on Ti alloys under simulated biological conditions
    • Hodgson A.W.E., Mueller Y., Forster D., Virtanen S. Electrochemical characterisation of passive films on Ti alloys under simulated biological conditions. Electrochim. Acta 2002, 47:1913-1923.
    • (2002) Electrochim. Acta , vol.47 , pp. 1913-1923
    • Hodgson, A.W.E.1    Mueller, Y.2    Forster, D.3    Virtanen, S.4
  • 10
    • 0002848362 scopus 로고
    • Biological effects of corrosion products from metals
    • ASTM STP 859, Philadelphia, PA, A.C. Fraker, C.D. Griffin (Eds.)
    • Merritt K., Brown S.A. Biological effects of corrosion products from metals. Corrosion and Degradation of Implant Materials 1983, 195-207. ASTM STP 859, Philadelphia, PA. A.C. Fraker, C.D. Griffin (Eds.).
    • (1983) Corrosion and Degradation of Implant Materials , pp. 195-207
    • Merritt, K.1    Brown, S.A.2
  • 11
    • 0038925728 scopus 로고
    • Metal implants - historical background and biological response to implantation
    • C.V. Mosby, St. Louis, MO, L.R. Rubin (Ed.)
    • Cohen J. Metal implants - historical background and biological response to implantation. Biomaterials in Reconstructive Surgery 1979, 46-61. C.V. Mosby, St. Louis, MO. L.R. Rubin (Ed.).
    • (1979) Biomaterials in Reconstructive Surgery , pp. 46-61
    • Cohen, J.1
  • 12
    • 23144459229 scopus 로고    scopus 로고
    • Synthesis, structure and electrochemical behavior of a beta Ti-12Mo-5Ta alloy as new biomaterial
    • Gordin D.M., Gloriant T., Nemtoi Gh., Chelariu R., Aelenei N., Guillou A., Ansel D. Synthesis, structure and electrochemical behavior of a beta Ti-12Mo-5Ta alloy as new biomaterial. Mater. Lett. 2005, 59:2959-2964.
    • (2005) Mater. Lett. , vol.59 , pp. 2959-2964
    • Gordin, D.M.1    Gloriant, T.2    Nemtoi, G.3    Chelariu, R.4    Aelenei, N.5    Guillou, A.6    Ansel, D.7
  • 13
    • 40049089439 scopus 로고    scopus 로고
    • Wear response of heat treated Ti-13Nb-13Zr alloy in dry condition and simulated body fluid
    • Majumdar P., Singh S.B., Chakraborty M. Wear response of heat treated Ti-13Nb-13Zr alloy in dry condition and simulated body fluid. Wear 2008, 264:1015-1025.
    • (2008) Wear , vol.264 , pp. 1015-1025
    • Majumdar, P.1    Singh, S.B.2    Chakraborty, M.3
  • 14
    • 0032023387 scopus 로고    scopus 로고
    • Mechanical properties of biomedical titanium alloys
    • Niinomi M. Mechanical properties of biomedical titanium alloys. Mater. Sci. Eng. A 1998, 243:231-236.
    • (1998) Mater. Sci. Eng. A , vol.243 , pp. 231-236
    • Niinomi, M.1
  • 15
    • 0032170254 scopus 로고    scopus 로고
    • Titanium alloys in total joint replacement - a materials science perspective
    • Long M., Rack H.J. Titanium alloys in total joint replacement - a materials science perspective. Biomaterials 1998, 19:1621-1639.
    • (1998) Biomaterials , vol.19 , pp. 1621-1639
    • Long, M.1    Rack, H.J.2
  • 16
    • 0000689059 scopus 로고    scopus 로고
    • Recent metallic materials for biomedical applications
    • Niinomi M. Recent metallic materials for biomedical applications. Metall. Mater. Trans. A 2002, 33:477-486.
    • (2002) Metall. Mater. Trans. A , vol.33 , pp. 477-486
    • Niinomi, M.1
  • 18
    • 78650704198 scopus 로고    scopus 로고
    • Tribocorrosion behavior of β titanium alloys in physiological solutions containing synovial components
    • More N.S., Diomidis N., Paul S.N., Roy M., Mischler S. Tribocorrosion behavior of β titanium alloys in physiological solutions containing synovial components. Mater. Sci. Eng. C 2011, 31:400-408.
    • (2011) Mater. Sci. Eng. C , vol.31 , pp. 400-408
    • More, N.S.1    Diomidis, N.2    Paul, S.N.3    Roy, M.4    Mischler, S.5
  • 19
    • 0036563573 scopus 로고    scopus 로고
    • A tribo-electrochemical apparatus for in vitro investigation of fretting-corrosion of metallic implant materials
    • Barril S., Debaud N., Mischler S., Landolt D. A tribo-electrochemical apparatus for in vitro investigation of fretting-corrosion of metallic implant materials. Wear 2002, 252:744-754.
    • (2002) Wear , vol.252 , pp. 744-754
    • Barril, S.1    Debaud, N.2    Mischler, S.3    Landolt, D.4
  • 20
    • 4243612176 scopus 로고    scopus 로고
    • Wear analysis in fretting of hard coatings through a dissipated energy concept
    • Fouvry S., Kapsa Ph., Zahouani H., Vincent L. Wear analysis in fretting of hard coatings through a dissipated energy concept. Wear 1997, 203-204:393-493.
    • (1997) Wear , pp. 393-493
    • Fouvry, S.1    Kapsa, P.2    Zahouani, H.3    Vincent, L.4
  • 21
    • 0027807808 scopus 로고
    • The surface characterization of titanium and titanium-nickel alloys in sulfuric acid
    • Asami K., Chen S.C., Habazaki H., Hashimoto K. The surface characterization of titanium and titanium-nickel alloys in sulfuric acid. Corros. Sci. 1993, 35:43-49.
    • (1993) Corros. Sci. , vol.35 , pp. 43-49
    • Asami, K.1    Chen, S.C.2    Habazaki, H.3    Hashimoto, K.4
  • 22
    • 0017439987 scopus 로고
    • The X-ray photo-electron spectra of several oxides of iron and chromium
    • Asami K., Hashimoto K. The X-ray photo-electron spectra of several oxides of iron and chromium. Corros. Sci. 1977, 17:559-570.
    • (1977) Corros. Sci. , vol.17 , pp. 559-570
    • Asami, K.1    Hashimoto, K.2
  • 24
    • 0041627840 scopus 로고    scopus 로고
    • The effect of mechanical and electrochemical parameters on the tribocorrosion rate of stainless steel in sulphuric acid
    • Stemp M., Mischler S., Landolt D. The effect of mechanical and electrochemical parameters on the tribocorrosion rate of stainless steel in sulphuric acid. Wear 2003, 255:466-475.
    • (2003) Wear , vol.255 , pp. 466-475
    • Stemp, M.1    Mischler, S.2    Landolt, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.