1
-
-
79955445949
-
Sources of image degradation in fundamental and harmonic ultrasound imaging: A nonlinear, full-wave, simulation study
-
Apr.
-
G. F. Pinton, G. E. Trahey, and J. J. Dahl, "Sources of image degradation in fundamental and harmonic ultrasound imaging: A nonlinear, full-wave, simulation study," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 58, no. 4, pp. 754-765, Apr. 2011.
-
(2011)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.58
, Issue.4
, pp. 754-765
-
-
Pinton, G.F.1
Trahey, G.E.2
Dahl, J.J.3
-
2
-
-
0032766225
-
Clinical use of ultrasound tissue harmonic imaging
-
DOI 10.1016/S0301-5629(99)00060-5, PII S0301562999000605
-
F. Tranquart, N. Grenier, V. Eder, and L. Pourcelot, "Clinical use of ultrasound tissue harmonic imaging," Ultrasound Med. Biol., vol. 25, no. 6, pp. 889-894, Jul. 1999. (Pubitemid 29325761)
-
(1999)
Ultrasound in Medicine and Biology
, vol.25
, Issue.6
, pp. 889-894
-
-
Tranquart, F.1
Grenier, N.2
Eder, V.3
Pourcelot, L.4
-
3
-
-
0031867607
-
Tissue harmonic imaging: Why does it work?
-
DOI 10.1016/S0894-7317(98)70055-0
-
J. D. Thomas and D. N. Rubin, "Tissue harmonic imaging: Why does it work?" J. Am. Soc. Echocardiogr., vol. 11, no. 8, pp. 803-808, Aug. 1998. (Pubitemid 28376390)
-
(1998)
Journal of the American Society of Echocardiography
, vol.11
, Issue.8
, pp. 803-808
-
-
Thomas, J.D.1
Rubin, D.N.2
-
4
-
-
0033907017
-
Nonlinear propagation in ultrasonic fields: Measurements, modelling and harmonic imaging
-
DOI 10.1016/S0041-624X(99)00122-5
-
V. F. Humphrey, "Nonlinear propagation in ultrasonic fields: Measurements, modelling, and harmonic imaging," Ultrasonics, vol. 38, no. 1-8, pp. 267-272, 2000. (Pubitemid 30592566)
-
(2000)
Ultrasonics
, vol.38
, Issue.1
, pp. 267-272
-
-
Humphrey, V.F.1
-
5
-
-
0034221015
-
Comparison of tissue harmonic imaging with conventional US in abdominal disease
-
S. Choudhry, B. Gorman, J. W. Charboneau, D. J. Tradup, R. J. Beck, J. M. Kofler, and D. S. Groth, "Comparison of tissue harmonic imaging with conventional US in abdominal disease," Radiographics, vol. 20, no. 4, pp. 1127-1135, 2000.
-
(2000)
Radiographics
, vol.20
, Issue.4
, pp. 1127-1135
-
-
Choudhry, S.1
Gorman, B.2
Charboneau, J.W.3
Tradup, D.J.4
Beck, R.J.5
Kofler, J.M.6
Groth, D.S.7
-
6
-
-
0345491387
-
Tissue harmonic imaging: Utility in abdominal and pelvic sonography
-
DOI 10.1002/(SICI)1097-0096(199903/04)27:3<135::AID-JCU6>3.0.CO;2-P
-
T. S. Desser, R. B. Jeffrey, M. J. Lane, and P. W. Ralls, "Pictorial essay: Tissue harmonic imaging: Utility in abdominal and pelvic sonography," J. Clin. Ultrasound, vol. 27, no. 3, pp. 135-142, Mar./ Apr. 1999. (Pubitemid 29084995)
-
(1999)
Journal of Clinical Ultrasound
, vol.27
, Issue.3
, pp. 135-142
-
-
Desser, T.S.1
Brooke Jeffrey Jr., R.2
Lane, M.J.3
Ralls, P.W.4
-
7
-
-
0031812621
-
Native tissue harmonic imaging improves endocardial border definition and visualization of cardiac structures
-
DOI 10.1053/je.1998.v11.a90474
-
M. Kornbluth, D. H. Liang, A. Paloma, and I. Schnittger, "Native tissue harmonic imaging improves endocardial border definition and visualization of cardiac structures," J. Am. Soc. Echocardiogr., vol. 11, pp. 693-701, Jul. 1998. (Pubitemid 28335127)
-
(1998)
Journal of the American Society of Echocardiography
, vol.11
, Issue.7
, pp. 693-701
-
-
Kornbluth, M.1
Liang, D.H.2
Paloma, A.3
Schnittger, I.4
-
8
-
-
17644395942
-
Experimental comparisons of the impact of abdominal wall aberrators on linear and nonlinear beam patterns
-
U1-H-4, Proceedings - 2004 IEEE Ultrasonics Symposium: A Conference of the IEEE International Ultrasonics, Ferroelectrics, and Frequency Control Society, UFFC-S
-
K. D. Wallace, B. S. Robinson, M. R. Holland, M. R. Rielly, and J. G. Miller, "Experimental comparisons of the impact of abdominal wall aberrators on linear and nonlinear beam patterns," in 2004 IEEE Ultrasonics Symp., vol. 2, pp. 866-869. (Pubitemid 40926871)
-
(2004)
Proceedings - IEEE Ultrasonics Symposium
, vol.2
, pp. 866-869
-
-
Wallace, K.D.1
Robinson, B.S.2
Holland, M.R.3
Rielly, M.R.4
Miller, J.G.5
-
9
-
-
0032530158
-
Use of harmonic imaging without echocardiographic contrast to improve two-dimensional image quality
-
Sep.
-
K. T. Spencer, J. Bednarz, P. G. Rafter, C. Korcarz, and R. M. Lang, "Use of harmonic imaging without echocardiographic contrast to improve two-dimensional image quality," Am. J. Cardiol., vol. 82, no. 6, pp. 794-799, Sep. 1998.
-
(1998)
Am. J. Cardiol.
, vol.82
, Issue.6
, pp. 794-799
-
-
Spencer, K.T.1
Bednarz, J.2
Rafter, P.G.3
Korcarz, C.4
Lang, R.M.5
-
10
-
-
33947681717
-
Aberration in nonlinear acoustic wave propagation
-
DOI 10.1109/TUFFC.2007.271
-
T. Varslot, S.-E. Masoy, and T. F. J. B. Angelsen, "Aberration in nonlinear acoustic wave propagation," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 54, no. 3, pp. 470-479, Mar. 2007. (Pubitemid 46495666)
-
(2007)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.54
, Issue.3
, pp. 470-479
-
-
Varslot, T.1
Masoy, S.-E.2
Johansen, T.F.3
Angelsen, B.4
-
12
-
-
0030849582
-
Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging
-
T. Christopher, "Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 44, no. 1, pp. 125-139, 1997. (Pubitemid 127771197)
-
(1997)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.44
, Issue.1
, pp. 125-139
-
-
Christopher, T.1
-
13
-
-
0031699682
-
Experimental investigation of finite amplitude distortion-based, second harmonic pulse echo ultrasonic imaging
-
T. Christopher, "Experimental investigation of finite amplitude distortion-based, second harmonic pulse echo ultrasonic imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 45, no. 1, pp. 158-162, 1998. (Pubitemid 128748675)
-
(1998)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.45
, Issue.1
, pp. 158-162
-
-
Christopher, T.1
-
15
-
-
0036195532
-
Nonlinear acoustics in diagnostic ultrasound
-
DOI 10.1016/S0301-5629(01)00463-X, PII S030156290100463X
-
F. Duck, "Nonlinear acoustics in diagnostic ultrasound," Ultrasound Med. Biol., vol. 28, no. 1, pp. 1-18, Jan. 2002. (Pubitemid 34202297)
-
(2002)
Ultrasound in Medicine and Biology
, vol.28
, Issue.1
, pp. 1-18
-
-
Duck, F.A.1
-
16
-
-
0018000447
-
Comprehensive compilation of empirical ultrasonic properties of mammalian tissues
-
DOI 10.1121/1.382016
-
S. A. Goss, R. L. Johnston, and F. Dunn, "Compilation of empirical ultrasonic properties of mammalian tissues," J. Acoust. Soc. Am., vol. 64, no. 2, pp. 423-457, 1978. (Pubitemid 9001200)
-
(1978)
Journal of the Acoustical Society of America
, vol.64
, Issue.2
, pp. 423-457
-
-
Goss, S.A.1
Johnston, R.L.2
Dunn, F.3
-
17
-
-
0019044539
-
Compilation of empirical ultrasonic properties of mammalian tissues, II
-
S. A. Goss, R. L. Johnston, and F. Dunn, "Compilation of empirical ultrasonic properties of mammalian tissues, II," J. Acoust. Soc. Am., vol. 68, no. 1, pp. 93-108, 1980.
-
(1980)
J. Acoust. Soc. Am.
, vol.68
, Issue.1
, pp. 93-108
-
-
Goss, S.A.1
Johnston, R.L.2
Dunn, F.3
-
18
-
-
0020273763
-
Quantitative ultrasonic backscatter measurements in the presence of phase distortion
-
M. O'Donnell, "Quantitative ultrasonic backscatter measurements in the presence of phase distortion," J. Acoust. Soc. Am., vol. 72, no. 6, pp. 1719-1725, 1982.
-
(1982)
J. Acoust. Soc. Am.
, vol.72
, Issue.6
, pp. 1719-1725
-
-
O'donnell, M.1
-
19
-
-
0023548789
-
Degradation of image quality by sound velocity fluctuations and its dependence on the aperture size
-
D. Hassler, W. Härer, G. Temme, E. Schmidt, P. Wegener, and P. Krmer, "Degradation of image quality by sound velocity fluctuations and its dependence on the aperture size," in Proc. IEEE Ultrasonics Symp., 1987, vol. 2, pp. 935-938. (Pubitemid 18656496)
-
(1987)
Ultrasonics Symposium Proceedings
, pp. 935-938
-
-
Hassler, D.1
Harer, W.2
Temme, G.3
Schmidt, E.4
Wegener, P.5
Krammer, P.6
-
20
-
-
0025968669
-
In vivo measurements of ultrasonic beam distortion in the breast
-
G. E. Trahey, P. D. Freiburger, L. F. Nock, and D. C. Sullivan, "In vivo measurements of ultrasonic beam distortion in the breast," Ultrason. Imaging, vol. 13, no. 1, pp. 71-90, 1991.
-
(1991)
Ultrason. Imaging
, vol.13
, Issue.1
, pp. 71-90
-
-
Trahey, G.E.1
Freiburger, P.D.2
Nock, L.F.3
Sullivan, D.C.4
-
21
-
-
84957277281
-
Large aperture phase error measurement and effects
-
H. W. Durgin, P. D. Freiburger, D. C. Sullivan, and G. E. Trahey, "Large aperture phase error measurement and effects," in Proc. IEEE Ultrasonics Symp., vol. 1, 1992, pp. 623-627.
-
(1992)
Proc. IEEE Ultrasonics Symp.
, vol.1
, pp. 623-627
-
-
Durgin, H.W.1
Freiburger, P.D.2
Sullivan, D.C.3
Trahey, G.E.4
-
22
-
-
0027076033
-
Simulation of B-scan images from two-dimensional transducer arrays: Part II - comparisons between linear and two-dimensional phased arrays
-
DOI 10.1016/0161-7346(92)90076-8
-
D. H. Turnbull and F. S. Foster, "Simulation of b-scan images from two-dimensional transducer arrays: Part II-Comparisons between linear and two-dimensional phased arrays," Ultrason. Imaging, vol. 14, no. 4, pp. 344-353, 1992. (Pubitemid 23108364)
-
(1992)
Ultrasonic Imaging
, vol.14
, Issue.4
, pp. 344-353
-
-
Turnbull, D.H.1
Foster, F.S.2
-
23
-
-
0026444042
-
Large-transducer measurements of wavefront distortion in the female breast
-
Q. Zhu and B. D. Steinberg, "Large-transducer measurements of wavefront distortion in the female breast," Ultrason. Imaging, vol. 14, no. 3, pp. 276-299, 1992.
-
(1992)
Ultrason. Imaging
, vol.14
, Issue.3
, pp. 276-299
-
-
Zhu, Q.1
Steinberg, B.D.2
-
24
-
-
27644452594
-
Computer simulation of forward wave propagation in soft tissue
-
Sep.
-
T. Varslot and G. Taraldsen, "Computer simulation of forward wave propagation in soft tissue," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 52, no. 9, pp. 1473-1482, Sep. 2005.
-
(2005)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.52
, Issue.9
, pp. 1473-1482
-
-
Varslot, T.1
Taraldsen, G.2
-
26
-
-
0030861024
-
Simulation of ultrasonic pulse propagation through the abdominal wall
-
Aug.
-
T. D. Mast, L. M. Hinkelman, M. J. Orr, V. W. Sparrow, and R. C. Waag, "Simulation of ultrasonic pulse propagation through the abdominal wall," J. Acoust. Soc. Am., vol. 102, no. 2, pp. 1177-1190, Aug. 1997.
-
(1997)
J. Acoust. Soc. Am.
, vol.102
, Issue.2
, pp. 1177-1190
-
-
Mast, T.D.1
Hinkelman, L.M.2
Orr, M.J.3
Sparrow, V.W.4
Waag, R.C.5
-
27
-
-
0013338806
-
Two- and three-dimensional simulations of ultrasonic propagation through human breast tissue
-
DOI 10.1121/1.1447722
-
T. D. Mast, "Two- and three-dimensional simulations of ultrasonic propagation through human breast tissue," Acoust. Res. Lett. Online, vol. 3, no. 2, pp. 53-58, 2002. (Pubitemid 38847196)
-
(2002)
Acoustic Research Letters Online
, vol.3
, pp. 53-58
-
-
Mast, T.D.1
-
28
-
-
65349139522
-
A heterogeneous nonlinear attenuating full-wave model of ultrasound
-
G. Pinton, J. Dahl, S. Rosenzweig, and G. Trahey, "A heterogeneous nonlinear attenuating full-wave model of ultrasound," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 56, no. 3, pp. 474-488, 2009.
-
(2009)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.56
, Issue.3
, pp. 474-488
-
-
Pinton, G.1
Dahl, J.2
Rosenzweig, S.3
Trahey, G.4
-
29
-
-
0034224415
-
Computer model for harmonic ultrasound imaging
-
DOI 10.1109/58.869075
-
Y. D. Li and J. A. Zagzebski, "Computer model for harmonic ultrasound imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 47, no. 5, pp. 1259-1272, Sep. 2000. (Pubitemid 32025364)
-
(2000)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.47
, Issue.5
, pp. 1259-1272
-
-
Li, Y.1
Zagzebski, J.A.2
-
30
-
-
0023916824
-
Phase aberration measurements in medical ultrasound: Human studies
-
M. O'Donnell and S. W. Flax, "Phase aberration measurements in medical ultrasound: Human studies," Ultrason. Imaging, vol. 10, no. 1, pp. 1-11, 1988.
-
(1988)
Ultrason. Imaging
, vol.10
, Issue.1
, pp. 1-11
-
-
O'donnell, M.1
Flax, S.W.2
-
31
-
-
0027078779
-
Two dimensional ultrasonic beam distortion in the breast: In vivo measurements and effects
-
DOI 10.1016/0161-7346(92)90080-F
-
P. D. Freiburger, D. C. Sullivan, B. H. LeBlanc, S. W. Smith, and G. E. Trahey, "Two dimensional ultrasonic beam distortion in the breast: In vivo measurements and effects," Ultrason. Imaging, vol. 14, no. 4, pp. 398-414, 1992. (Pubitemid 23108368)
-
(1992)
Ultrasonic Imaging
, vol.14
, Issue.4
, pp. 398-414
-
-
Freiburger, P.D.1
Sullivan, D.C.2
LeBlanc, B.H.3
Smith, S.W.4
Trahey, G.E.5
-
32
-
-
0027976907
-
Measurements of ultrasonic pulse arrival time and energy level variations produced by propagation through abdominal wall
-
L. M. Hinkelman, D. Liu, L. A. Metlay, and R. C. Waag, "Measurements of ultrasonic pulse arrival time and energy level variations produced by propagation through abdominal wall," J. Acoust. Soc. Am., vol. 95, no. 1, pp. 530-541, 1994. (Pubitemid 24027850)
-
(1994)
Journal of the Acoustical Society of America
, vol.95
, Issue.1
, pp. 530-541
-
-
Hinkelman, L.M.1
Liu, D.-L.2
Metlay, L.A.3
Waag, R.C.4
-
33
-
-
0030968538
-
Measurements of ultrasonic pulse distortion produced by human chest wall
-
DOI 10.1121/1.418248
-
L. M. Hinkelman, T. L. Szabo, and R. C. Waag, "Measurements of ultrasonic pulse distortion produced by human chest wall," J. Acoust. Soc. Am., vol. 101, no. 4, pp. 2365-2373, 1997. (Pubitemid 27163999)
-
(1997)
Journal of the Acoustical Society of America
, vol.101
, Issue.4
, pp. 2365-2373
-
-
Hinkelman, L.M.1
Szabo, T.L.2
Waag, R.C.3
-
35
-
-
84953658909
-
Parametric acoustic array
-
P. J. Westervelt, "Parametric acoustic array," J. Acoust. Soc. Am.,vol. 35, pp. 535-537, 1963.
-
(1963)
J. Acoust. Soc. Am.
, vol.35
, pp. 535-537
-
-
Westervelt, P.J.1
-
37
-
-
24044478820
-
Field: A program for simulating ultrasound systems
-
J. A. Jensen, "Field: A program for simulating ultrasound systems," Med. Biol. Eng. Comp., col. 10th Nordic-Baltic Conference on Biomedical Imaging, vol. 4, no. 1, pp. 351-353, 1996.
-
(1996)
Med. Biol. Eng. Comp., Col. 10th Nordic-Baltic Conference on Biomedical Imaging
, vol.4
, Issue.1
, pp. 351-353
-
-
Jensen, J.A.1
-
38
-
-
28044459877
-
A perfectly matched layer for the absorption of electromagnetic waves
-
DOI 10.1006/jcph.1994.1159
-
J.-P. Berenger, "A perfectly matched layer for the absorption of electromagnetic waves," J. Comput. Phys., vol. 114, no. 2, pp. 185-200, 1994. (Pubitemid 124012822)
-
(1994)
Journal of Computational Physics
, vol.114
, Issue.2
, pp. 185-200
-
-
Berenger, J.-P.1
-
39
-
-
0030444273
-
Perfectly matched layers for elastodynamics: A new absorbing boundary condition
-
W. C. Chew and Q. H. Liu, "Perfectly matched layers for elastodynamics: A new absorbing boundary condition," J. Comput. Acoust., vol. 4, no. 4, pp. 72-79, 1996.
-
(1996)
J. Comput. Acoust.
, vol.4
, Issue.4
, pp. 72-79
-
-
Chew, W.C.1
Liu, Q.H.2
-
40
-
-
0030882734
-
The perfectly matched layer for acoustic waves in absorptive media
-
DOI 10.1121/1.419657
-
Q. -H. Liu and J. Tao, "The perfectly matched layer for acoustic waves in absorbtive media," J. Acoust. Soc. Am., vol. 102, no. 4, pp. 2072-2082, 1997. (Pubitemid 27441357)
-
(1997)
Journal of the Acoustical Society of America
, vol.102
, Issue.4
, pp. 2072-2082
-
-
Liu, Q.-H.1
Tao, J.2
-
41
-
-
67651191642
-
-
Ph.D. dissertation Dept. of Biomedical Engineering, Duke University, Durham, NC
-
G. Pinton, "Numerical methods for nonlinear wave propagation in ultrasound," Ph.D. dissertation, Dept. of Biomedical Engineering, Duke University, Durham, NC, 2007.
-
(2007)
Numerical Methods for Nonlinear Wave Propagation in Ultrasound
-
-
Pinton, G.1
-
42
-
-
0029826179
-
Modified Gomori trichrome stain for macroscopic tissue slices
-
L. M. Hinkelman, L. A. Metlay, C. J. Churukian, and R. C. Waag, "Modified Gomori trichrome stain technique for macroscopic tissue slices," J. Histotechnol., vol. 19, no. 4, pp. 321-323, 1996. (Pubitemid 26415092)
-
(1996)
Journal of Histotechnology
, vol.19
, Issue.4
, pp. 321-323
-
-
Hinkelman, L.M.1
Metlay, L.A.2
Churukian, C.J.3
Waag, R.C.4
-
43
-
-
0037327109
-
Simulation of ultrasonic focus aberration and correction through human tissue
-
DOI 10.1121/1.1531986
-
M. Tabei, T. D. Mast, and R. Waag, "Simulation of ultrasonic focus aberration and correction through human tissue," J. Acoust. Soc. Am., vol. 113, no. 2, pp. 1166-1176, 2003. (Pubitemid 36240743)
-
(2003)
Journal of the Acoustical Society of America
, vol.113
, Issue.2
, pp. 1166-1176
-
-
Tabei, M.1
Mast, T.D.2
Waag, R.C.3
-
45
-
-
33845640211
-
Adaptive imaging on a diagnostic ultrasound scanner at quasi real-time rates
-
DOI 10.1109/TUFFC.2006.115
-
J. J. Dahl, S. A. McAleavey, G. F. Pinton, M. S. Soo, and G. E. Trahey, "Adaptive imaging on a diagnostic ultrasound scanner at quasi real-time rates," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 10, pp. 1832-1843, 2006. (Pubitemid 44946559)
-
(2006)
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
, vol.53
, Issue.10
, pp. 1832-1843
-
-
Dahl, J.J.1
McAleavey, S.A.2
Pinton, G.F.3
Soo, M.S.4
Trahey, G.E.5
-
46
-
-
0034579968
-
Improved in vivo abdominal image quality using real-time estimation and correction of wavefront arrival time errors
-
K. W. Rigby, C. L. Chalek, B. H. Haider, R. S. Lewandowski, M. O,Donnell, L. S. Smith, and D. G. Wildes, "Improved in vivo abdominal image quality using real-time estimation and correction of wavefront arrival time errors," in Proc. IEEE Ultrasonics Symp., 2000, vol. 2, pp. 1645-1653. (Pubitemid 34079672)
-
(2000)
Proceedings of the IEEE Ultrasonics Symposium
, vol.2
, pp. 1645-1653
-
-
Rigby, K.W.1
Chalek, C.L.2
Haider, B.H.3
Lewandowski, R.S.4
O'Donnell, M.5
Smith, L.S.6
Wildes, D.G.7
|