메뉴 건너뛰기




Volumn 55, Issue 5, 2011, Pages 548-555

Self-pacing as a protective mechanism against the effects of heat stress

Author keywords

heat adaptation behaviour; heat management; heat stress; manual work; self pacing; thermal strain; Thermal Work Limit

Indexed keywords

HEAT ADAPTATION BEHAVIOUR; HEAT MANAGEMENT; HEAT STRESS; MANUAL WORK; SELF-PACING; THERMAL STRAIN; THERMAL WORK LIMIT;

EID: 79959512172     PISSN: 00034878     EISSN: 14753162     Source Type: Journal    
DOI: 10.1093/annhyg/mer012     Document Type: Article
Times cited : (70)

References (17)
  • 2
    • 53349127439 scopus 로고    scopus 로고
    • Hydration status and physiological workload of UAE construction workers: A prospective longitudinal observational study
    • Bates GP, Schneider JD. (2008) Hydration status and physiological workload of UAE construction workers: a prospective longitudinal observational study. J OccupMedToxicol; 3: 21.
    • (2008) J OccupMedToxicol , vol.3 , pp. 21
    • Bates, G.P.1    Schneider, J.D.2
  • 4
    • 0036168694 scopus 로고    scopus 로고
    • Limiting metabolic rate (Thermal Work Limit) as an index of thermal stress
    • DOI 10.1080/104732202753438261
    • Brake DJ, Bates GP. (2002b) Limiting metabolic rate (thermal work limit) as an index of thermal stress. Appl Occup Environ Hyg; 17: 176-86. (Pubitemid 34163857)
    • (2002) Applied Occupational and Environmental Hygiene , vol.17 , Issue.3 , pp. 176-186
    • Brake, D.J.1    Bates, G.P.2
  • 5
    • 79959525891 scopus 로고
    • Heart rate interpretation and methodology
    • Eastman Kodak Company New York, NY: John Wiley and Sons
    • Eastman Kodak Company. (1986) Heart rate interpretation and methodology. In Human Factors Section, editor. Ergonomic design for people at work. New York, NY: John Wiley and Sons. pp. 174-81.
    • (1986) Human Factors Section, Editor. Ergonomic Design for People at Work , pp. 174-181
  • 7
    • 1542513845 scopus 로고    scopus 로고
    • The "golden hour" for heatstroke treatment
    • Heled Y, Rav-Acha M, Shani Y, et al. (2004) The "golden hour" for heatstroke treatment. Mil Med; 169: 184-6.
    • (2004) Mil Med , vol.169 , pp. 184-186
    • Heled, Y.1    Rav-Acha, M.2    Shani, Y.3
  • 8
    • 34547937732 scopus 로고    scopus 로고
    • Experimental research on physiological index at the heat tolerance limits in China
    • DOI 10.1016/j.buildenv.2006.06.029, PII S0360132306003726
    • Lu S, Zhu N. (2007) Experimental research on physiological index at the heat tolerance limits in China. Build Environ; 42: 4016-21. (Pubitemid 47264041)
    • (2007) Building and Environment , vol.42 , Issue.12 , pp. 4016-4021
    • Lu, S.1    Zhu, N.2
  • 9
    • 0842327734 scopus 로고    scopus 로고
    • Exercise time to fatigue and the critical limiting temperature: Effect of hydration
    • DOI 10.1016/j.jtherbio.2003.08.008
    • Marino FE, Kay D, Serwach N. (2004) Exercise time to fatigue and the critical limiting temperature: effect of hydration. J Therm Biol; 29: 21-9. (Pubitemid 38169033)
    • (2004) Journal of Thermal Biology , vol.29 , Issue.1 , pp. 21-29
    • Marino, F.E.1    Kay, D.2    Serwach, N.3
  • 10
    • 33745431026 scopus 로고    scopus 로고
    • Heat stress, plasma concentrations of adrenaline, noradrenaline, 5-hydroxytryptamine and cortisol, mood state and cognitive performance
    • DOI 10.1016/j.ijpsycho.2005.10.002, PII S0167876005002588
    • McMorris T, Swain J, Smith M et al. (2006) Heat stress, plasma concentrations of adrenaline, noradrenaline, 5- hydroxytryptamine and cortisol, mood state and cognitive performance. Int J Psychophysiol; 61: 204-15. (Pubitemid 43947290)
    • (2006) International Journal of Psychophysiology , vol.61 , Issue.2 , pp. 204-215
    • McMorris, T.1    Swain, J.2    Smith, M.3    Corbett, J.4    Delves, S.5    Sale, C.6    Harris, R.C.7    Potter, J.8
  • 11
    • 38849098462 scopus 로고    scopus 로고
    • The thermal work limit is a simple reliable heat index for the protection of workers in thermally stressful environments
    • DOI 10.1093/annhyg/mem035
    • Miller VS, Bates GP. (2007) The thermal work limit is a simple reliable heat index for the protection of workers in thermally stressful environments. Ann Occup Hyg; 51: 553-61. (Pubitemid 351194616)
    • (2007) Annals of Occupational Hygiene , vol.51 , Issue.6 , pp. 553-561
    • Miller, V.S.1    Bates, G.P.2
  • 14
    • 0037104687 scopus 로고    scopus 로고
    • Effects of hot and cold temperature exposure on performance: A meta-analytic review
    • DOI 10.1080/00140130210158419
    • Pilcher JJ, Nadler E, Busch C. (2002) Effects of hot and cold temperature exposure on performance: a meta-analytic review. Ergonomics; 45: 682-98. (Pubitemid 35331093)
    • (2002) Ergonomics , vol.45 , Issue.10 , pp. 682-698
    • Pilcher, J.J.1    Nadler, E.2    Busch, C.3
  • 15
    • 0001564716 scopus 로고    scopus 로고
    • Thermoregulatory responses to acute exercise-heat stress and heat acclimation
    • Fregley M, Blatteis C, editors New York, NY: Oxford University Press
    • Sawka MN, Wenger C, Pandolf KB. (1996) Thermoregulatory responses to acute exercise-heat stress and heat acclimation. In Fregley M, Blatteis C, editors. Handbook of physiology section 4 environmental physiology. New York, NY: Oxford University Press; pp. 157-83.
    • (1996) Handbook of Physiology Section 4 Environmental Physiology , pp. 157-183
    • Sawka, M.N.1    Wenger, C.2    Pandolf, K.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.