메뉴 건너뛰기




Volumn 32, Issue 12, 2011, Pages 1457-1464

Telemonitoring in chronic heart failure

Author keywords

Haemodynamic monitoring; Intracardiac pressures; Intrathoracic impedance; Telehomecare; Telemonitoring

Indexed keywords

ACETYLSALICYLIC ACID; CLOPIDOGREL; ISOSORBIDE DINITRATE; LISINOPRIL; TORASEMIDE; WARFARIN;

EID: 79959385943     PISSN: 0195668X     EISSN: 15229645     Source Type: Journal    
DOI: 10.1093/eurheartj/ehr005     Document Type: Review
Times cited : (44)

References (36)
  • 5
    • 79957450058 scopus 로고    scopus 로고
    • Telemedical interventional monitoring in heart failure (TIM-HF), a randomized, controlled intervention trial investigating the impact of telemedicine on mortality in ambulatory patients with chronic heart failure
    • (abstract 21835)
    • Kö hler F, Winkler S, Schieber M, Sechtem U, Stangl K, Böhm M, Boll H, Gelbrich G, Kirwan BA, Anker SD. Telemedical interventional monitoring in heart failure (TIM-HF), a randomized, controlled intervention trial investigating the impact of telemedicine on mortality in ambulatory patients with chronic heart failure. Circulation 2010;122:2224 (abstract 21835).
    • (2010) Circulation , vol.122 , pp. 2224
    • Kö Hler, F.1    Winkler, S.2    Schieber, M.3    Sechtem, U.4    Stangl, K.5    Böhm, M.6    Boll, H.7    Gelbrich, G.8    Kirwan, B.A.9    Anker, S.D.10
  • 6
    • 44649122064 scopus 로고    scopus 로고
    • Expert consensus on the monitoring of cardiovascular implantable electronic devices: Description of techniques, indications, personnel, frequency and ethical considerations
    • HRS/EHRA
    • HRS/EHRA. Expert consensus on the monitoring of cardiovascular implantable electronic devices: description of techniques, indications, personnel, frequency and ethical considerations. Europace 2008;10:707-725.
    • (2008) Europace , vol.10 , pp. 707-725
  • 7
    • 0031686381 scopus 로고    scopus 로고
    • Atrial fibrillation is associated with an increased risk for mortality and heart failure progression in patients with asymptomatic and symptomatic left ventricular systolic dysfunction: A retrospective analysis of the SOLVD trials
    • DOI 10.1016/S0735-1097(98)00297-6, PII S0735109798002976
    • Dries DL, Exner DV, Gersch BJ. Atrial fibrillation is associated with increased risk for mortality and heart failure progression in patients with asymptomatic and symptomatic left ventricular dysfunction. J Am Coll Cardiol 1998;S32:695-703. (Pubitemid 28435256)
    • (1998) Journal of the American College of Cardiology , vol.32 , Issue.3 , pp. 695-703
    • Dries, D.L.1    Exner, D.V.2    Gersh, B.J.3    Domanski, M.J.4    Waclawiw, M.A.5    Stevenson, L.W.6
  • 8
    • 0028354909 scopus 로고
    • Mortensen LS chronic congestive cardiac failure. Description and survival of 190 consecutive patients with a diagnosis of chronic congestive cardiac failure based on clinical signs and symptoms
    • Madsen BK, Hansen JF, Stokholm KH, Brons J, Husum D. Mortensen LS chronic congestive cardiac failure. Description and survival of 190 consecutive patients with a diagnosis of chronic congestive cardiac failure based on clinical signs and symptoms. Eur Heart J 1994;15:304-306.
    • (1994) Eur Heart J , vol.15 , pp. 304-306
    • Madsen, B.K.1    Hansen, J.F.2    Stokholm, K.H.3    Brons, J.4    Husum, D.5
  • 9
    • 12844258988 scopus 로고    scopus 로고
    • Detection of atrial fibrillation by implanted devices with wireless data transmission capability
    • DOI 10.1111/j.1540-8159.2005.00083.x
    • Varma NJ, Stambler B, Chun S. Detection of atrial fibrillation by implantable devices with wireless data transmission capability. Pacing Clin Electrophysiol 2005; 28:S133-S136. (Pubitemid 40171101)
    • (2005) PACE - Pacing and Clinical Electrophysiology , vol.28 , Issue.SUPPL. 1
    • Varma, N.1    Stambler, B.2    Chun, S.3
  • 10
    • 33645394387 scopus 로고    scopus 로고
    • Predicting mortality and rehospitalisation in heart failure patients with home monitoring-the Home CARE pilot study
    • Ellery S, Pakrashi T, Paul V, Sack S. Predicting mortality and rehospitalisation in heart failure patients with home monitoring-the Home CARE pilot study. Clin Res Cardiol 2006;95(Suppl. 3):III29-III35.
    • (2006) Clin Res Cardiol , vol.95 , Issue.SUPPL. 3
    • Ellery, S.1    Pakrashi, T.2    Paul, V.3    Sack, S.4
  • 11
    • 6444228048 scopus 로고    scopus 로고
    • Continuous autonomic assessment in patients with symptomatic heart failure: Prognostic value of heart rate variability measured by an implanted cardiac resynchronization device
    • DOI 10.1161/01.CIR.0000139841.42454.78
    • Adamson PB, Smith AL, Abraham WT, Kleckner KJ, Stadler RW, Shih A, Rhodes MM. InSync III model8042 and Attain OTW Model4193 Clinical Trial Investigators. Continuous autonomic assessment in patients with symptomatic heart failure: prognostic value of heart rate variability measured by an implanted cardiac resynchronisation device. Circulation 2004;110:2389-2394. (Pubitemid 39407344)
    • (2004) Circulation , vol.110 , Issue.16 , pp. 2389-2394
    • Adamson, P.B.1    Smith, A.L.2    Abraham, W.T.3    Kleckner, K.J.4    Stadler, R.W.5    Shih, A.6    Rhodes, M.M.7
  • 12
    • 84855983873 scopus 로고    scopus 로고
    • Automated HF Decompensation Detection: Results from the DECOmpensation DEtection Study (DECODE) Accessed 31 January 2011
    • Ewald GA, Gilliam FR, Sweeney RJ. Automated HF Decompensation Detection: Results from the DECOmpensation DEtection Study (DECODE). Boston Scientific, http://lb7.reedexpo.fr/Data/kmreed-cardiostim/block/F-33b0a783b23452 fedafec826faaffbd84bb349b5cb6bc.pdf. Accessed 31 January 2011.
    • Boston Scientific
    • Ewald, G.A.1    Gilliam, F.R.2    Sweeney, R.J.3
  • 13
    • 34248633374 scopus 로고    scopus 로고
    • Remote Active Monitoring in Patients With Heart Failure (RAPID-RF): Design and Rationale
    • DOI 10.1016/j.cardfail.2006.12.004, PII S1071916406012966
    • Saxon LA, Boehmer JP, Neuman S, Mullin CM. Remote active monitoring in patients with heart failure (RAPID-RF): design and rationale. J Card Fail 2007;13: 241-246. (Pubitemid 46766636)
    • (2007) Journal of Cardiac Failure , vol.13 , Issue.4 , pp. 241-246
    • Saxon, L.A.1    Boehmer, J.P.2    Neuman, S.3    Mullin, C.M.4
  • 14
    • 34547936744 scopus 로고    scopus 로고
    • Physiological approach to monitor patients in congestive heart failure: Application of a new implantable device-based system to monitor daily life activity and ventilation
    • DOI 10.1093/europace/eum066
    • Page E, Cazeau S, Ritter P, Galley D, Casset C. Physiological approach to monitor patients in congestive heart failure: application of a new implantable device-based system to monitor daily life activity and ventilation. Europace 2007;9:687-693. (Pubitemid 47263805)
    • (2007) Europace , vol.9 , Issue.8 , pp. 687-693
    • Page, E.1    Cazeau, S.2    Ritter, P.3    Galley, D.4    Casset, C.5
  • 15
    • 23844525145 scopus 로고    scopus 로고
    • Intrathoracic impedance monitoring in patients with heart failure: Correlation with fluid status and feasibility of early warning preceding hospitalization
    • DOI 10.1161/CIRCULATIONAHA.104.492207
    • Yu CM, Wang L, Chau E, Chan R, Kong S, Tang M, Christensen J, Stadler RW, Lau CP. Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization. Circulation 2005;112:841-848. (Pubitemid 41170070)
    • (2005) Circulation , vol.112 , Issue.6 , pp. 841-848
    • Yu, C.-M.1    Wang, L.2    Chau, E.3    Chan, R.H.-W.4    Kong, S.-L.5    Tang, M.-O.6    Christensen, J.7    Stadler, R.W.8    Lau, C.-P.9
  • 16
    • 78650689907 scopus 로고    scopus 로고
    • Superior performance of intrathoracic impedance-derived fluid index versus daily weight monitoring in heart failure patients: Results of the fluid accumulation status trial (FAST)
    • Abraham WT, Compton S, Haas G, Canby RC, Fishel R, McRae S, Toledo G, Sarkar S. Superior performance of intrathoracic impedance-derived fluid index versus daily weight monitoring in heart failure patients: results of the fluid accumulation status trial (FAST). J Cardiac Fail 2009;15:813.
    • (2009) J Cardiac Fail , vol.15 , pp. 813
    • Abraham, W.T.1    Compton, S.2    Haas, G.3    Canby, R.C.4    Fishel, R.5    McRae, S.6    Toledo, G.7    Sarkar, S.8
  • 21
    • 0036097960 scopus 로고    scopus 로고
    • Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: A multicenter, 12-month follow-up study of patients with chronic heart failure
    • DOI 10.1054/jcaf.2002.32373
    • Magalski A, Adamson P, Gadler F, Böhm M, Steinhaus D, Reynolds D, Vlach K, Linde C, Cremers B, Sparks B, Bennett T. Continuous ambulatory right heart pressure measurements with an implantable hemodynamic monitor: a multicenter 12-month follow-up study of patients with chronic heart failure. J Card Fail 2002;8:63-70. (Pubitemid 34521414)
    • (2002) Journal of Cardiac Failure , vol.8 , Issue.2 , pp. 63-70
    • Magalski, A.1    Adamson, P.2    Gadler, F.3    Boehm, M.4    Steinhaus, D.5    Reynolds, D.6    Vlach, K.7    Linde, C.8    Cremers, B.9    Sparks, B.10    Bennett, T.11
  • 23
    • 0028929801 scopus 로고
    • Measurement of pulmonary artery diastolic pressure from the right ventricle
    • Reynolds D, Bartelt N, Taepke RT, Bennett TD. Measurement of pulmonary artery diastolic pressure from the right ventricle. J Am Coll Cardiol 1995;25: 1176-1182.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1176-1182
    • Reynolds, D.1    Bartelt, N.2    Taepke, R.T.3    Bennett, T.D.4
  • 24
    • 0029257708 scopus 로고
    • Monitoring of pulmonary arterial diastolic pressure through a right ventricular pressure transducer
    • Ohlsson A, Bennett T, Nordlander R, Ryden J, Astrom H, Ryden L. Monitoring of pulmonary arterial diastolic pressure through a right ventricular pressure transducer. J Card Fail 1995;1:161-168.
    • (1995) J Card Fail , vol.1 , pp. 161-168
    • Ohlsson, A.1    Bennett, T.2    Nordlander, R.3    Ryden, J.4    Astrom, H.5    Ryden, L.6
  • 27
    • 30344453054 scopus 로고    scopus 로고
    • The heartpod implantable heart failure therapy system
    • DOI 10.1016/j.hlc.2005.09.003
    • Walton AS, Krum H. The Heartpod implantable heart failure therapy system. Heart Lung Circ 2005;14S:S31-S33. (Pubitemid 43056013)
    • (2005) Heart Lung and Circulation , vol.14 , Issue.SUPPL. 2
    • Walton, A.S.1    Krum, H.2
  • 30
    • 37449007194 scopus 로고    scopus 로고
    • Comparison of a Radiofrequency-Based Wireless Pressure Sensor to Swan-Ganz Catheter and Echocardiography for Ambulatory Assessment of Pulmonary Artery Pressure in Heart Failure
    • DOI 10.1016/j.jacc.2007.06.061, PII S0735109707031178
    • Verdejo HE, Castro PF, Concepión R, Ferrada MA, Alfaro MA, Alcaino ME, Deck CC, Bourge RC. Comparison of a radiofrequency-based wireless pressure sensor to swan-ganz catheter and echocardiography for ambulatory assessment of pulmonary artery pressure in heart failure. J Am Coll Cardiol 2007;50: 2375-2382. (Pubitemid 50011581)
    • (2007) Journal of the American College of Cardiology , vol.50 , Issue.25 , pp. 2375-2382
    • Verdejo, H.E.1    Castro, P.F.2    Concepcion, R.3    Ferrada, M.A.4    Alfaro, M.A.5    Alcaino, M.E.6    Deck, C.C.7    Bourge, R.C.8
  • 32
    • 77955453178 scopus 로고    scopus 로고
    • Clinical trials update from the European society of cardiology heart failure meeting 2010: TRIDENT 1, BENEFICIAL, CUPID, RFA-HF, MUSIC, DUEL, handheld BNP, phrenic nerve stimulation, CHAMPION and CABG with CRT study
    • Cleland JGF, Coletta AP, Clark AL. Clinical trials update from the European Society of Cardiology Heart Failure Meeting 2010: TRIDENT 1, BENEFICIAL, CUPID, RFA-HF, MUSIC, DUEL, handheld BNP, phrenic nerve stimulation, CHAMPION and CABG with CRT study. Eur J Heart Fail 2010;12:883-888.
    • (2010) Eur J Heart Fail , vol.12 , pp. 883-888
    • Jgf, C.1    Coletta, A.P.2    Clark, A.L.3
  • 33
    • 70450089204 scopus 로고    scopus 로고
    • Multiple vector impedance measurements during biventricular pacing: Feasibility and possible implications for hemodynamic monitoring
    • Valzania C, Eriksson MJ, Holmström N, Järverud K, Gadler F. Multiple vector impedance measurements during biventricular pacing: feasibility and possible implications for hemodynamic monitoring. Pacing Clin Electrophysiol 2009;32: 1492-1500.
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. 1492-1500
    • Valzania, C.1    Eriksson, M.J.2    Holmström, N.3    Järverud, K.4    Gadler, F.5
  • 34
    • 73649124618 scopus 로고    scopus 로고
    • Intrathoracic and ventricular impedances are associated with changes in ventricular volume in patients receiving defibrillators for CRT
    • Valsecchi S on behalf of the Italian Clinical Service Optivol-CRT Group
    • Maines M, Landolina M, Lunati M, Lonardi G, Pappone A, Proclemer A, Zanotto G, Santini M, Varbaro A, Vimercati M, Valsecchi S on behalf of the Italian Clinical Service Optivol-CRT Group. Intrathoracic and ventricular impedances are associated with changes in ventricular volume in patients receiving defibrillators for CRT. Pacing Clin Electrophysiol 2010;33:64-73.
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 64-73
    • Maines, M.1    Landolina, M.2    Lunati, M.3    Lonardi, G.4    Pappone, A.5    Proclemer, A.6    Zanotto, G.7    Santini, M.8    Varbaro, A.9    Vimercati, M.10
  • 36
    • 46749089019 scopus 로고    scopus 로고
    • Impact of telehealth on clinical outcomes in patients with heart failure
    • Dansky KH, Vasey J, Bowles K. Impact of telehealth on clinical outcomes in patients with heart failure. Clin Nurs Res 2008;17:182-199.
    • (2008) Clin Nurs Res , vol.17 , pp. 182-199
    • Dansky, K.H.1    Vasey, J.2    Bowles, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.