메뉴 건너뛰기




Volumn 13, Issue 1, 2011, Pages

Value of black blood T2* cardiovascular magnetic resonance

Author keywords

[No Author keywords available]

Indexed keywords

IRON;

EID: 79958864832     PISSN: 10976647     EISSN: 1532429X     Source Type: Journal    
DOI: 10.1186/1532-429X-13-21     Document Type: Article
Times cited : (39)

References (18)
  • 1
    • 0020034796 scopus 로고
    • Survival and desferrioxamine in thalassaemia major
    • Survival and desferrioxamine in thalassaemia major. Modell B, Letsky EA, Flynn DM, Peto R, Weatherall DJ, Br Med J 1982 284 1081 4 10.1136/bmj.284.6322. 1081 (Pubitemid 12135972)
    • (1982) British Medical Journal , vol.284 , Issue.6322 , pp. 1081-1084
    • Modell, B.1    Letsky, E.A.2    Flynn, D.M.3
  • 4
    • 0021833690 scopus 로고
    • Prevention of cardiac disease by subcutaneous deferoxamine in patients with thalassemia major
    • Prevention of cardiac disease by subcutaneous deferoxamine in patients with thalassemia major. Wolfe L, Olivieri N, Sallan D, Colan S, Rose V, Propper R, Freedman MH, Nathan DG, N Engl J Med 1985 312 1600 3 10.1056/ NEJM198506203122503 4000198 (Pubitemid 15062652)
    • (1985) New England Journal of Medicine , vol.312 , Issue.25 , pp. 1600-1603
    • Wolfe, L.1    Olivieri, N.2    Sallan, D.3
  • 6
    • 57349095277 scopus 로고    scopus 로고
    • Improved survival of thalassaemia major in the UK and relation to T2* cardiovascular magnetic resonance
    • 10.1186/1532-429X-10-42 18817553
    • Improved survival of thalassaemia major in the UK and relation to T2* cardiovascular magnetic resonance. Modell B, Khan M, Darlison M, Westwood MA, Ingram D, Pennell DJ, J Cardiovasc Magn Reson 2008 10 42 10.1186/1532-429X-10-42 18817553
    • (2008) J Cardiovasc Magn Reson , vol.10 , pp. 42
    • Modell, B.1    Khan, M.2    Darlison, M.3    Westwood, M.A.4    Ingram, D.5    Pennell, D.J.6
  • 7
    • 73949117408 scopus 로고    scopus 로고
    • Update on survival in thalassemia major
    • 10.3109/03630260903347336 20001636
    • Update on survival in thalassemia major. Telfer P, Hemoglobin 2009 33 76 80 10.3109/03630260903347336 20001636
    • (2009) Hemoglobin , vol.33 , pp. 1976-1980
    • Telfer, P.1
  • 12
    • 34247103036 scopus 로고    scopus 로고
    • A randomized, placebo-controlled, double-blind trial of the effect of combined therapy with deferoxamine and deferiprone on myocardial iron in thalassemia major using cardiovascular magnetic resonance
    • DOI 10.1161/CIRCULATIONAHA.106.648790
    • A randomized, placebo-controlled, double-blind trial of the effect of combined therapy with deferoxamine and deferiprone on myocardial iron in thalassemia major using cardiovascular magnetic resonance. Tanner MA, Galanello R, Dessi C, Smith GC, Westwood MA, Agus A, Roughton M, Assomull R, Nair SV, Walker JM, Pennell DJ, Circulation 2007 115 1876 84 10.1161/CIRCULATIONAHA.106. 648790 17372174 (Pubitemid 46598901)
    • (2007) Circulation , vol.115 , Issue.14 , pp. 1876-1884
    • Tanner, M.A.1    Galanello, R.2    Dessi, C.3    Smith, G.C.4    Westwood, M.A.5    Agus, A.6    Roughton, M.7    Assomull, R.8    Nair, S.V.9    Walker, J.M.10    Pennell, D.J.11
  • 15
    • 0031862930 scopus 로고    scopus 로고
    • 2(*) and field inhomogeneity maps in the human heart at 1.5 T
    • DOI 10.1002/mrm.1910390617
    • In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T. Reeder SB, Faranesh AZ, Boxerman JL, McVeigh ER, Magn Reson Med 1998 39 988 98 10.1002/mrm.1910390617 9621923 (Pubitemid 28237758)
    • (1998) Magnetic Resonance in Medicine , vol.39 , Issue.6 , pp. 988-998
    • Reeder, S.B.1    Faranesh, A.Z.2    Boxerman, J.L.3    McVeigh, E.R.4
  • 17
    • 55749111009 scopus 로고    scopus 로고
    • Myocardial T2* measurements in iron-overloaded thalassemia: An in vivo study to investigate optimal methods of quantification
    • 10.1002/mrm.21744 18956471
    • Myocardial T2* measurements in iron-overloaded thalassemia: An in vivo study to investigate optimal methods of quantification. He T, Gatehouse PD, Smith GC, Mohiaddin RH, Pennell DJ, Firmin DN, Magn Reson Med 2008 60 1082 9 10.1002/mrm.21744 18956471
    • (2008) Magn Reson Med , vol.60 , pp. 1082-1089
    • He, T.1    Gatehouse, P.D.2    Smith, G.C.3    Mohiaddin, R.H.4    Pennell, D.J.5    Firmin, D.N.6
  • 18
    • 0036104746 scopus 로고    scopus 로고
    • Breath-hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility
    • Breath-Hold FLASH and FISP cardiovascular MR imaging: Left ventricular volume differences and reproducibility. Moon JC, Lorenz CH, Francis JM, Smith GC, Pennell DJ, Radiology 2002 223 789 97 10.1148/radiol.2233011181 12034951 (Pubitemid 34547599)
    • (2002) Radiology , vol.223 , Issue.3 , pp. 789-797
    • Moon, J.C.C.1    Lorenz, C.H.2    Francis, J.M.3    Smith, G.C.4    Pennell, D.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.