메뉴 건너뛰기




Volumn 20, Issue 5, 2011, Pages 740-746

Medial support by fibula bone graft in angular stable plate fixation of proximal humeral fractures: An in vitro study with synthetic bone

Author keywords

Fibula graft; Locking plate; Medial support; Proximal humeral fracture

Indexed keywords

PLASTIC;

EID: 79958833144     PISSN: 10582746     EISSN: 15326500     Source Type: Journal    
DOI: 10.1016/j.jse.2010.10.040     Document Type: Article
Times cited : (98)

References (39)
  • 2
    • 10944263139 scopus 로고    scopus 로고
    • Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year
    • Bjorkenheim J.M., Pajarinen J., Savolainen V. Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand 2004, 75:741-745. 10.1080/00016470410004120.
    • (2004) Acta Orthop Scand , vol.75 , pp. 741-745
    • Bjorkenheim, J.M.1    Pajarinen, J.2    Savolainen, V.3
  • 3
    • 68049114654 scopus 로고    scopus 로고
    • Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis
    • Brunner F., Sommer C., Bahrs C., Heuwinkel R., Hafner C., Rillmann P., et al. Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis. J Orthop Trauma 2009, 23:163-172. 10.1097/BOT.0b013e3181920e5b.
    • (2009) J Orthop Trauma , vol.23 , pp. 163-172
    • Brunner, F.1    Sommer, C.2    Bahrs, C.3    Heuwinkel, R.4    Hafner, C.5    Rillmann, P.6
  • 4
    • 0015648310 scopus 로고
    • The effect of movement on the bonding of porous metal to bone
    • Cameron H.U., Pilliar R.M., Macnab I. The effect of movement on the bonding of porous metal to bone. J Biomed Mater Res 1973, 7:301-311.
    • (1973) J Biomed Mater Res , vol.7 , pp. 301-311
    • Cameron, H.U.1    Pilliar, R.M.2    Macnab, I.3
  • 5
    • 46049109525 scopus 로고    scopus 로고
    • A mechanical comparison between conventional and modified angular plates for proximal humeral fractures
    • Carrera E.F., Nicolao F.A., Netto N.A., Carvalho R.L., Dos Reis F.B., Giordani E.J. A mechanical comparison between conventional and modified angular plates for proximal humeral fractures. J Shoulder Elbow Surg 2008, 17:631-636. 10.1016/j.jse.2008.02.003.
    • (2008) J Shoulder Elbow Surg , vol.17 , pp. 631-636
    • Carrera, E.F.1    Nicolao, F.A.2    Netto, N.A.3    Carvalho, R.L.4    Dos Reis, F.B.5    Giordani, E.J.6
  • 8
    • 54849433115 scopus 로고    scopus 로고
    • Structural properties of a novel design of composite analogue humeri models
    • Dunlap J., Chong A., Lucas G., Cooke F. Structural properties of a novel design of composite analogue humeri models. Ann Biomed Eng 2008, 36:1922-1926. 10.1007/s10439-008-9568-y.
    • (2008) Ann Biomed Eng , vol.36 , pp. 1922-1926
    • Dunlap, J.1    Chong, A.2    Lucas, G.3    Cooke, F.4
  • 9
    • 0032430986 scopus 로고    scopus 로고
    • Power and sample size calculations for studies involving linear regression
    • Dupont W.D., Plummer W.D. Power and sample size calculations for studies involving linear regression. Controlled Clin Trials 1998, 589-601. 10.1016/S0197-2456(98)00037-3.
    • (1998) Controlled Clin Trials , pp. 589-601
    • Dupont, W.D.1    Plummer, W.D.2
  • 10
    • 13844270862 scopus 로고    scopus 로고
    • Two-part surgical neck fractures of the humerus: mechanical analysis of the fixation with four Shanz-type threaded pins in four different assemblies
    • Durigan A., Barbieri C.H., Mazzer N., Shimano A.C. Two-part surgical neck fractures of the humerus: mechanical analysis of the fixation with four Shanz-type threaded pins in four different assemblies. J Shoulder Elbow Surg 2005, 14:96-102. 10.1016/j.jse.2004.04.013.
    • (2005) J Shoulder Elbow Surg , vol.14 , pp. 96-102
    • Durigan, A.1    Barbieri, C.H.2    Mazzer, N.3    Shimano, A.C.4
  • 11
    • 33749562322 scopus 로고    scopus 로고
    • Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques
    • Edwards S.L., Wilson N.A., Zhang L.-Q., Flores S., Merk B.R. Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques. J Bone Joint Surg Am 2006, 88:2258-2264. 10.2106/jbjs.e.00757.
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 2258-2264
    • Edwards, S.L.1    Wilson, N.A.2    Zhang, L.-Q.3    Flores, S.4    Merk, B.R.5
  • 13
    • 23244467336 scopus 로고    scopus 로고
    • An algorithm for estimation of shoulder muscle forces for clinical use
    • Favre P., Sheikh R., Fucentese S.F., Jacob H.A. An algorithm for estimation of shoulder muscle forces for clinical use. Clin Biomech (Bristol, Avon) 2005, 20:822-833. 10.1016/j.clinbiomech.2005.04.007.
    • (2005) Clin Biomech (Bristol, Avon) , vol.20 , pp. 822-833
    • Favre, P.1    Sheikh, R.2    Fucentese, S.F.3    Jacob, H.A.4
  • 14
    • 70350491294 scopus 로고    scopus 로고
    • Philos plate fixation for displaced proximal humeral fractures
    • Fazal M.A., Haddad F.S. Philos plate fixation for displaced proximal humeral fractures. J Orthop Surg (Hong Kong) 2009, 17:15-18.
    • (2009) J Orthop Surg (Hong Kong) , vol.17 , pp. 15-18
    • Fazal, M.A.1    Haddad, F.S.2
  • 15
    • 34547115714 scopus 로고    scopus 로고
    • Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants
    • Fuchtmeier B., May R., Hente R., Maghsudi M., Völk M., Hammer J., et al. Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants. Arch Orthop Trauma Surg 2007, 127:441-447. 10.1007/s00402-007-0319-6.
    • (2007) Arch Orthop Trauma Surg , vol.127 , pp. 441-447
    • Fuchtmeier, B.1    May, R.2    Hente, R.3    Maghsudi, M.4    Völk, M.5    Hammer, J.6
  • 16
    • 43249115352 scopus 로고    scopus 로고
    • Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant
    • Gardner M., Boraiah S., Helfet D., Lorich D. Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant. J Orthop Trauma 2008, 22:195-200. 10.1097/BOT.0b013e31815b3922.
    • (2008) J Orthop Trauma , vol.22 , pp. 195-200
    • Gardner, M.1    Boraiah, S.2    Helfet, D.3    Lorich, D.4
  • 17
    • 38449090846 scopus 로고    scopus 로고
    • Second-generation concepts for locked plating of proximal humerus fractures
    • Gardner M., Lorich D., Werner C., Helfet D. Second-generation concepts for locked plating of proximal humerus fractures. Am J Orthop (Belle Mead NJ) 2007, 36:460-465. 10.1097/BOT.0b013e3180333094.
    • (2007) Am J Orthop (Belle Mead NJ) , vol.36 , pp. 460-465
    • Gardner, M.1    Lorich, D.2    Werner, C.3    Helfet, D.4
  • 18
    • 34247563357 scopus 로고    scopus 로고
    • The importance of medial support in locked plating of proximal humerus fractures
    • Gardner M.J., Weil Y., Barker J.U., Kelly B.T., Helfet D.L., Lorich D.G. The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma 2007, 21:185-191. 10.1097/BOT.0b013e3180333094.
    • (2007) J Orthop Trauma , vol.21 , pp. 185-191
    • Gardner, M.J.1    Weil, Y.2    Barker, J.U.3    Kelly, B.T.4    Helfet, D.L.5    Lorich, D.G.6
  • 19
    • 0025635811 scopus 로고
    • The arterial vascularization of the humeral head. An anatomical study
    • Gerber C., Schneeberger A., Vinh T. The arterial vascularization of the humeral head. An anatomical study. J Bone Joint Surg Am 1990, 72:1486-1494.
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 1486-1494
    • Gerber, C.1    Schneeberger, A.2    Vinh, T.3
  • 20
    • 5644304280 scopus 로고    scopus 로고
    • Die Versorgung dislozierter 3- und 4-Fragmentfrakturen des proximalen Humerus mit einem winkelstabilen Plattenfixateur
    • Hente R., Kampshoff J., Kinner B., Füchtmeier B., Nerlich M. Die Versorgung dislozierter 3- und 4-Fragmentfrakturen des proximalen Humerus mit einem winkelstabilen Plattenfixateur. Unfallchirurg 2004, 107:769-782. 10.1007/s00113-004-0818-7.
    • (2004) Unfallchirurg , vol.107 , pp. 769-782
    • Hente, R.1    Kampshoff, J.2    Kinner, B.3    Füchtmeier, B.4    Nerlich, M.5
  • 21
    • 44949262177 scopus 로고    scopus 로고
    • Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study
    • [in German]
    • Hessmann M.H., Korner J., Hofmann A., Sternstein W., Rommens P.M. Angle-fixed plate fixation or double-plate osteosynthesis in fractures of the proximal humerus: a biomechanical study. Biomed Tech (Berl) 2008, 53:130-137. [in German]. 10.1515/BMT.2008.018.
    • (2008) Biomed Tech (Berl) , vol.53 , pp. 130-137
    • Hessmann, M.H.1    Korner, J.2    Hofmann, A.3    Sternstein, W.4    Rommens, P.M.5
  • 22
  • 24
    • 78549267138 scopus 로고    scopus 로고
    • The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support
    • Lescheid J., Zdero R., Shah S., Kuzyk P.R., Schemitsch E.H. The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support. J Trauma 2010, 69:1235-1242. 10.1097/TA.0b013e3181beed96.
    • (2010) J Trauma , vol.69 , pp. 1235-1242
    • Lescheid, J.1    Zdero, R.2    Shah, S.3    Kuzyk, P.R.4    Schemitsch, E.H.5
  • 25
    • 0038338590 scopus 로고    scopus 로고
    • Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens
    • Lill H., Hepp P., Korner J., Kassi J.P., Verheyden A.P., Josten C., et al. Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens. Arch Orthop Trauma Surg 2003, 123:74-81. 10.1007/s00402-002-0465-9.
    • (2003) Arch Orthop Trauma Surg , vol.123 , pp. 74-81
    • Lill, H.1    Hepp, P.2    Korner, J.3    Kassi, J.P.4    Verheyden, A.P.5    Josten, C.6
  • 27
    • 77955658258 scopus 로고    scopus 로고
    • Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft
    • Mathison C., Chaudhary R., Beaupre L., Reynolds M., Adeeb S., Bouliane M. Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft. Clin Biomech 2010, 25:642-646. 10.1016/j.clinbiomech.2010.04.006.
    • (2010) Clin Biomech , vol.25 , pp. 642-646
    • Mathison, C.1    Chaudhary, R.2    Beaupre, L.3    Reynolds, M.4    Adeeb, S.5    Bouliane, M.6
  • 28
    • 70349685127 scopus 로고    scopus 로고
    • Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fractures
    • Micic I.D., Kim K.C., Shin D.J., Shin S.J., Kim P.T., Park I.H., et al. Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fractures. J Orthop Sci 2009, 14:596-601. 10.1007/s00776-009-1382-3.
    • (2009) J Orthop Sci , vol.14 , pp. 596-601
    • Micic, I.D.1    Kim, K.C.2    Shin, D.J.3    Shin, S.J.4    Kim, P.T.5    Park, I.H.6
  • 29
    • 70449528661 scopus 로고    scopus 로고
    • Mid-term results of internal fixation of proximal humeral fractures with the Philos plate
    • Papadopoulos P., Karataglis D., Stavridis S.I., Petsatodis G., Christodoulou A. Mid-term results of internal fixation of proximal humeral fractures with the Philos plate. Injury 2009, 40:1292-1296. 10.1016/j.injury.2009.03.008.
    • (2009) Injury , vol.40 , pp. 1292-1296
    • Papadopoulos, P.1    Karataglis, D.2    Stavridis, S.I.3    Petsatodis, G.4    Christodoulou, A.5
  • 32
    • 4844225504 scopus 로고    scopus 로고
    • Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws
    • Seebeck J., Goldhahn J., Städele H., Messmer P., Morlock M., Schneider E. Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws. J Orthop Res 2004, 22:1237-1242. 10.1016/j.orthres.2004.04.001.
    • (2004) J Orthop Res , vol.22 , pp. 1237-1242
    • Seebeck, J.1    Goldhahn, J.2    Städele, H.3    Messmer, P.4    Morlock, M.5    Schneider, E.6
  • 33
    • 56149111888 scopus 로고    scopus 로고
    • Outcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital
    • Shahid R., Mushtaq A., Northover J., Maqsood M. Outcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital. Acta Orthop Belg 2008, 74:602-608.
    • (2008) Acta Orthop Belg , vol.74 , pp. 602-608
    • Shahid, R.1    Mushtaq, A.2    Northover, J.3    Maqsood, M.4
  • 34
    • 0026898331 scopus 로고
    • Quantitation of in situ contact areas at the glenohumeral joint: a biomechanical study
    • Soslowsky L.J., Flatow E.L., Bigliani L.U., Pawluk R.J., Ateshian G.A., Mow V.C. Quantitation of in situ contact areas at the glenohumeral joint: a biomechanical study. J Orthop Res 1992, 10:524-534. 10.1002/jor.1100100407.
    • (1992) J Orthop Res , vol.10 , pp. 524-534
    • Soslowsky, L.J.1    Flatow, E.L.2    Bigliani, L.U.3    Pawluk, R.J.4    Ateshian, G.A.5    Mow, V.C.6
  • 35
    • 70349748800 scopus 로고    scopus 로고
    • Treatment of proximal humerus fractures with locking plates: a systematic review
    • Thanasas C., Kontakis G., Angoules A., Limb D., Giannoudis P. Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elbow Surg 2009, 18:837-844. 10.1016/j.jse.2009.06.004.
    • (2009) J Shoulder Elbow Surg , vol.18 , pp. 837-844
    • Thanasas, C.1    Kontakis, G.2    Angoules, A.3    Limb, D.4    Giannoudis, P.5
  • 36
    • 33750632703 scopus 로고    scopus 로고
    • Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model
    • Walsh S., Reindl R., Harvey E., Berry G., Beckman L., Steffen T. Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model. Clin Biomech (Bristol, Avon) 2006, 21:1027-1031. 10.1016/j.clinbiomech.2006.06.005.
    • (2006) Clin Biomech (Bristol, Avon) , vol.21 , pp. 1027-1031
    • Walsh, S.1    Reindl, R.2    Harvey, E.3    Berry, G.4    Beckman, L.5    Steffen, T.6
  • 37
    • 77952543497 scopus 로고    scopus 로고
    • Influence of the fixation stability on the healing time-A numerical study of a patient-specific fracture healing process
    • Wehner T., Claes L., Niemeyer F., Nolte D., Simon U. Influence of the fixation stability on the healing time-A numerical study of a patient-specific fracture healing process. Clin Biomech 2010, 25:606-612. 10.1016/j.clinbiomech.2010.03.003.
    • (2010) Clin Biomech , vol.25 , pp. 606-612
    • Wehner, T.1    Claes, L.2    Niemeyer, F.3    Nolte, D.4    Simon, U.5
  • 38
    • 0031179758 scopus 로고    scopus 로고
    • Biomechanical comparison of intramedullary and percutaneous pin fixation for proximal humeral fracture fixation
    • Wheeler D.L., Colville M.R. Biomechanical comparison of intramedullary and percutaneous pin fixation for proximal humeral fracture fixation. J Orthop Trauma 1997, 11:363-367.
    • (1997) J Orthop Trauma , vol.11 , pp. 363-367
    • Wheeler, D.L.1    Colville, M.R.2
  • 39
    • 0029294161 scopus 로고
    • A dynamic shoulder model: reliability testing and muscle force study
    • Wuelker N., Wirth C.J., Plitz W., Roetman B. A dynamic shoulder model: reliability testing and muscle force study. J Biomech 1995, 28:489-499.
    • (1995) J Biomech , vol.28 , pp. 489-499
    • Wuelker, N.1    Wirth, C.J.2    Plitz, W.3    Roetman, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.