메뉴 건너뛰기




Volumn 19, Issue 7, 2011, Pages 1141-1147

The impact of a rectangular or trapezoidal flexion gap on the femoral component rotation in TKA

Author keywords

Computed tomography; Femoral component rotation; Gap technique; Total knee arthroplasty

Indexed keywords

AGED; ARTICLE; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; FEMUR; HISTOLOGY; HUMAN; KNEE; KNEE ARTHROPLASTY; KNEE OSTEOARTHRITIS; MALE; METHODOLOGY; MIDDLE AGED; PROSPECTIVE STUDY; ROTATION; TREATMENT OUTCOME;

EID: 79958827765     PISSN: 09422056     EISSN: 14337347     Source Type: Journal    
DOI: 10.1007/s00167-011-1422-3     Document Type: Article
Times cited : (16)

References (21)
  • 1
    • 0032418168 scopus 로고    scopus 로고
    • Malrotation causing patellofemoral complications after total knee arthroplasty
    • Berger R, Crossett L, Jacobs J, Rubash H (1998) Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 356: 144-153.
    • (1998) Clin Orthop Relat Res , vol.356 , pp. 144-153
    • Berger, R.1    Crossett, L.2    Jacobs, J.3    Rubash, H.4
  • 2
    • 0027400765 scopus 로고
    • Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis
    • Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286: 40-47.
    • (1993) Clin Orthop Relat Res , vol.286 , pp. 40-47
    • Berger, R.A.1    Rubash, H.E.2    Seel, M.J.3    Thompson, W.H.4    Crossett, L.S.5
  • 3
    • 2342432329 scopus 로고    scopus 로고
    • Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial
    • Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br 86: 372-377.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 372-377
    • Chauhan, S.K.1    Scott, R.G.2    Breidahl, W.3    Beaver, R.J.4
  • 4
    • 0022537079 scopus 로고
    • Technical considerations in total knee arthroplasty
    • Dorr LD, Boiardo RA (1986) Technical considerations in total knee arthroplasty. Clin Orthop Relat Res 205: 5-11.
    • (1986) Clin Orthop Relat Res , vol.205 , pp. 5-11
    • Dorr, L.D.1    Boiardo, R.A.2
  • 5
    • 0024950156 scopus 로고
    • The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system
    • Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248: 9-12.
    • (1989) Clin Orthop Relat Res , vol.248 , pp. 9-12
    • Ewald, F.C.1
  • 6
    • 0033752667 scopus 로고    scopus 로고
    • Rotational malalignment of the femoral component in total knee arthroplasty
    • Fehring TK (2000) Rotational malalignment of the femoral component in total knee arthroplasty. Clin Orthop Relat Res 380: 72-79.
    • (2000) Clin Orthop Relat Res , vol.380 , pp. 72-79
    • Fehring, T.K.1
  • 7
    • 77949569966 scopus 로고    scopus 로고
    • Biomechanical effects of patellar positioning on intraoperative knee joint gap measurement in total knee arthroplasty
    • Gejo R, McGarry MH, Jun B-J, Hofer JK, Kimura T, Lee TQ (2010) Biomechanical effects of patellar positioning on intraoperative knee joint gap measurement in total knee arthroplasty. Clin Biomech 25: 352-358.
    • (2010) Clin Biomech , vol.25 , pp. 352-358
    • Gejo, R.1    McGarry, M.H.2    Jun, B.-J.3    Hofer, J.K.4    Kimura, T.5    Lee, T.Q.6
  • 8
    • 0031693647 scopus 로고    scopus 로고
    • The posterior condylar angle in osteoarthritic knees
    • Griffin FM, Insall JN, Scuderi GR (1998) The posterior condylar angle in osteoarthritic knees. J Arthroplasty 13: 812-815.
    • (1998) J Arthroplasty , vol.13 , pp. 812-815
    • Griffin, F.M.1    Insall, J.N.2    Scuderi, G.R.3
  • 9
    • 34548439870 scopus 로고    scopus 로고
    • Bone landmarks are more reliable than tensioned gaps in TKA component alignment
    • Hanada H, Whiteside LA, Steiger J, Dyer P, Naito M (2007) Bone landmarks are more reliable than tensioned gaps in TKA component alignment. Clin Orthop Relat Res 462: 137-142.
    • (2007) Clin Orthop Relat Res , vol.462 , pp. 137-142
    • Hanada, H.1    Whiteside, L.A.2    Steiger, J.3    Dyer, P.4    Naito, M.5
  • 10
    • 62449248672 scopus 로고    scopus 로고
    • Effects of the balanced gap technique on femoral component rotation in TKA
    • Heesterbeek PJ, Jacobs WC, Wymenga AB (2009) Effects of the balanced gap technique on femoral component rotation in TKA. Clin Orthop Relat Res 467: 1015-1022.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 1015-1022
    • Heesterbeek, P.J.1    Jacobs, W.C.2    Wymenga, A.B.3
  • 12
    • 71849085147 scopus 로고    scopus 로고
    • Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty
    • Kim TK, Chang CB, Kang YG, Chung BJ, Cho HJ, Seong SC (2010) Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty. Knee 17: 23-28.
    • (2010) Knee , vol.17 , pp. 23-28
    • Kim, T.K.1    Chang, C.B.2    Kang, Y.G.3    Chung, B.J.4    Cho, H.J.5    Seong, S.C.6
  • 13
    • 46149086546 scopus 로고    scopus 로고
    • Relationship between the surgical epicondylar axis and the articular surface of the distal femur: an anatomic study
    • Lustig S, Lavoie F, Selmi TA, Servien E, Neyret P (2008) Relationship between the surgical epicondylar axis and the articular surface of the distal femur: an anatomic study. Knee Surg Sports Traumatol Arthrosc 16: 674-682.
    • (2008) Knee Surg Sports Traumatol Arthrosc , vol.16 , pp. 674-682
    • Lustig, S.1    Lavoie, F.2    Selmi, T.A.3    Servien, E.4    Neyret, P.5
  • 15
    • 79951725358 scopus 로고    scopus 로고
    • The gap technique does not rotate the femur parallel to the epicondylar axis
    • doi: 10. 1007/s00402-010-1113-4
    • Matziolis G, Boenicke H, Pfiel S, Wassilew G, Perka C (2010) The gap technique does not rotate the femur parallel to the epicondylar axis. Arch Orthop Trauma Surg. doi: 10. 1007/s00402-010-1113-4.
    • (2010) Arch Orthop Trauma Surg
    • Matziolis, G.1    Boenicke, H.2    Pfiel, S.3    Wassilew, G.4    Perka, C.5
  • 19
    • 78650075292 scopus 로고    scopus 로고
    • Optimized functional femoral rotation in navigated total knee arthroplasty considering ligament tension
    • doi: 10. 1016/j. knee. 2009. 12. 001
    • Walde TA, Bussert J, Sehmisch S, Balcarek P, Sturmer KM, Walde HJ, Frosch KH (2010) Optimized functional femoral rotation in navigated total knee arthroplasty considering ligament tension. Knee. doi: 10. 1016/j. knee. 2009. 12. 001.
    • (2010) Knee
    • Walde, T.A.1    Bussert, J.2    Sehmisch, S.3    Balcarek, P.4    Sturmer, K.M.5    Walde, H.J.6    Frosch, K.H.7
  • 20
    • 0036155739 scopus 로고    scopus 로고
    • Perfect balance in total knee arthroplasty: the elusive compromise
    • Winemaker MJ (2002) Perfect balance in total knee arthroplasty: the elusive compromise. J Arthroplasty 17: 2-10.
    • (2002) J Arthroplasty , vol.17 , pp. 2-10
    • Winemaker, M.J.1
  • 21
    • 0034984259 scopus 로고    scopus 로고
    • Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees
    • Yoshino N, Takai S, Ohtsuki Y, Hirasawa Y (2001) Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees. J Arthroplasty 16: 493-497.
    • (2001) J Arthroplasty , vol.16 , pp. 493-497
    • Yoshino, N.1    Takai, S.2    Ohtsuki, Y.3    Hirasawa, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.