메뉴 건너뛰기




Volumn , Issue , 2011, Pages

Supplementary control for damping power oscillations due to increased penetration of doubly fed induction generators in large power systems

Author keywords

Doubly fed induction generator; inertia; sensitivity; small signal stability; transient stability; wind turbine generators

Indexed keywords

ACTIVE POWER; ACTIVE POWER CONTROL; ADDITIONAL CONTROL; CONTROL MECHANISM; DAMPING POWER; DOUBLY FED INDUCTION GENERATORS; EIGENVALUE ANALYSIS; ELECTROMECHANICAL MODES; GRID FREQUENCY; IN-PHASE; INERTIA; INPUT SIGNAL; INTER-AREA MODES; LARGE POWER SYSTEMS; LOW FREQUENCY; POWER OUT PUT; POWER SYSTEM OSCILLATIONS; POWER SYSTEM STABILIZERS; SENSITIVITY; SETPOINTS; SMALL SIGNAL STABILITY; SYNCHRONOUS MACHINE; TERMINAL VOLTAGES; TEST SYSTEMS; WIND GENERATORS;

EID: 79958821442     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PSCE.2011.5772501     Document Type: Conference Paper
Times cited : (33)

References (9)
  • 3
    • 70049105469 scopus 로고    scopus 로고
    • Contribution of doubly fed wind generators to oscillation damping
    • September
    • G. Tsourakis, B. M. Nomikos, C. D. Vournas, "Contribution of doubly fed wind generators to oscillation damping," IEEE Trans. Energy Conversion, vol. 24, no. 3, September 2009.
    • (2009) IEEE Trans. Energy Conversion , vol.24 , Issue.3
    • Tsourakis, G.1    Nomikos, B.M.2    Vournas, C.D.3
  • 5
    • 77952227049 scopus 로고    scopus 로고
    • Modeling and Dynamic Behavior of Wind Generation as it Relates to Power System Control and Dynamic Performance
    • Working Group 01, Advisory Group 6, Study Committee C4, Draft Report, Aug.
    • CIGRE Technical Brochure "Modeling and Dynamic Behavior of Wind Generation as it Relates to Power System Control and Dynamic Performance," Working Group 01, Advisory Group 6, Study Committee C4, Draft Report, Aug. 2006.
    • (2006) CIGRE Technical Brochure
  • 9
    • 79151479221 scopus 로고    scopus 로고
    • Control strategy to mitigate the impact of reduced inertia due to doubly fed induction generators on large power systems
    • to appear in Digital Object Identifier 10.1109/TPWRS.2010.2051690
    • D. Gautam, L. Goel, R. Ayyanar, V. Vittal, "Control strategy to mitigate the impact of reduced inertia due to doubly fed induction generators on large power systems," to appear in IEEE Trans. Power Syst., Digital Object Identifier 10.1109/TPWRS.2010.2051690.
    • IEEE Trans. Power Syst.
    • Gautam, D.1    Goel, L.2    Ayyanar, R.3    Vittal, V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.