메뉴 건너뛰기




Volumn 112, Issue 1, 2011, Pages 28-33

An in vitro study of temperature changes in type 4 bone during implant placement: Bone condensing versus bone drilling

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ARTICLE; BODY TEMPERATURE; BONE DENSITY; COMPARATIVE STUDY; INSTRUMENTATION; MALE; METHODOLOGY; OSTEOTOMY; PATHOLOGY; PHYSIOLOGY; RANDOMIZATION; RIB; SWINE; THERMOMETER;

EID: 79958771094     PISSN: 10792104     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.tripleo.2010.08.010     Document Type: Article
Times cited : (29)

References (28)
  • 1
    • 0024031111 scopus 로고
    • A retrospective multicenter evaluation of osseointegrated implants supporting overdentures
    • Engquist B, Bergendal T, Kallus T, Linden U. A retrospective multicenter evaluation of osseointegrated implants supporting overdentures. Int J Oral Maxillofac Implants 1988;3:129-34.
    • (1988) Int J Oral Maxillofac Implants , vol.3 , pp. 129-134
    • Engquist, B.1    Bergendal, T.2    Kallus, T.3    Linden, U.4
  • 3
    • 0039184644 scopus 로고
    • Density of bone: Effect on treatment, planning, surgical approach and healing
    • Misch C, editor. St. Louis: Mosby
    • Misch C. Density of bone: effect on treatment, planning, surgical approach and healing. In: Misch C, editor. Contemporary implant dentistry. St. Louis: Mosby; 1993. p. 469-84.
    • (1993) Contemporary Implant Dentistry , pp. 469-484
    • Misch, C.1
  • 4
    • 0028373728 scopus 로고
    • A new concept in maxillary implant surgery: The osteotome technique
    • Summers RB. A new concept in maxillary implant surgery: the osteotome technique. Compend Contin Educ Dent 1994;15:152-60.
    • (1994) Compend Contin Educ Dent , vol.15 , pp. 152-160
    • Summers, R.B.1
  • 5
    • 0002455249 scopus 로고
    • Bone tissue response
    • Branemark PI, Zarb GA, Albrektsson T, editors. Chicago: Quintessence Publishing
    • Albrektsson T. Bone tissue response. In: Branemark PI, Zarb GA, Albrektsson T, editors. Tissue integrated prosthesis: osseointegration in clinical dentistry. Chicago: Quintessence Publishing; 1985. p. 129-40.
    • (1985) Tissue Integrated Prosthesis: Osseointegration in Clinical Dentistry , pp. 129-140
    • Albrektsson, T.1
  • 8
    • 0020790218 scopus 로고
    • Temperature threshold levels for heat-induced bone tissue injury: A vital microscopic study in the rabbit
    • Eriksson RA, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital microscopic study in the rabbit. J Prosthet Dent 1983;50:101-7.
    • (1983) J Prosthet Dent , vol.50 , pp. 101-107
    • Eriksson, R.A.1    Albrektsson, T.2
  • 10
    • 0027572074 scopus 로고
    • The effect of temperature, stress and microstructure on the creep of compact bovine bone
    • DOI 10.1016/0021-9290(93)90360-Q
    • Rimnac CM, Pekto AA, Santner TJ, Wright TM. The effect of temperature, stress and microstructure on the creep of compact bovine bone. J Biomech 1993;26:219-28. (Pubitemid 23099393)
    • (1993) Journal of Biomechanics , vol.26 , Issue.3 , pp. 219-228
    • Rimnac, C.M.1    Petko, A.A.2    Santner, T.J.3    Wright, T.M.4
  • 11
    • 0031264521 scopus 로고    scopus 로고
    • Effects of Drill Speed on Heat Production and the Rate and Quality of Bone Formation in Dental Implant Osteotomies. Part II: Relationship between Drill Speed and Healing
    • Iyer S, Weiss C, Mehta A. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing. Int J Prosthodont 1997;10:536-40. (Pubitemid 127500363)
    • (1997) International Journal of Prosthodontics , vol.10 , Issue.6 , pp. 536-540
    • Iyer, S.1    Weiss, C.2    Mehta, A.3
  • 12
    • 0029683215 scopus 로고    scopus 로고
    • The Effect of Speed, Pressure, and Time on Bone Temperature during the Drilling of Implant Sites
    • Brisman DL. The effect of speed, pressure and time on bone temperature during the drilling of implant sites. Int J Oral Maxillofac Implants 1996;11:35-7. (Pubitemid 126442751)
    • (1996) International Journal of Oral and Maxillofacial Implants , vol.11 , Issue.1 , pp. 35-37
    • Brisman, D.L.1
  • 15
    • 3042517588 scopus 로고    scopus 로고
    • The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: A study of drill durability
    • Ercoli C, Funkenbusch PD, Lee HJ, Moss ME, Graser GN. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. Int J Oral Maxillofac Implants 2004;19:335-49. (Pubitemid 38822321)
    • (2004) International Journal of Oral and Maxillofacial Implants , vol.19 , Issue.3 , pp. 335-349
    • Ercoli, C.1    Funkenbusch, P.D.2    Lee, H.-J.3    Moss, M.E.4    Graser, G.N.5
  • 16
    • 60049100274 scopus 로고    scopus 로고
    • Effects of irrigation temperature on heat control in vitro at different drilling depths
    • Sener BC, Dergin G, Gursoy B, Kelesoglu E, Slih I. Effects of irrigation temperature on heat control in vitro at different drilling depths. Clin Oral Implants Res 2009;20:294-8.
    • (2009) Clin Oral Implants Res , vol.20 , pp. 294-298
    • Sener, B.C.1    Dergin, G.2    Gursoy, B.3    Kelesoglu, E.4    Slih, I.5
  • 17
    • 71549160805 scopus 로고    scopus 로고
    • Effect of surgical drill guide on heat generated from implant drilling
    • Misir AF, Sumer M, Yenisey M, Ergioglu E. Effect of surgical drill guide on heat generated from implant drilling. J Oral Maxillofac Surg 2009;67:2663-8.
    • (2009) J Oral Maxillofac Surg , vol.67 , pp. 2663-2668
    • Misir, A.F.1    Sumer, M.2    Yenisey, M.3    Ergioglu, E.4
  • 18
    • 0031763862 scopus 로고    scopus 로고
    • Interspecies differences in bone composition, density, and quality: Potential implications for in vivo bone research
    • DOI 10.1210/en.139.2.663
    • Aerssen J, Boonen S, Lowet G, Dequeker J. Interspecies differences in bone composition, density, and quality: potential applications for in vivo bone research. Endocrinology 1998;139:663-70. (Pubitemid 28513217)
    • (1998) Endocrinology , vol.139 , Issue.2 , pp. 663-670
    • Aerssens, J.1    Boonen, S.2    Lowet, G.3    Dequeker, J.4
  • 19
    • 0013864447 scopus 로고
    • Factors affecting the determination of the physical properties of femoral cortical bone
    • Sedlin ED, Hirsch C. Factors affecting the determination of the physical properties of femoral cortical bone. Acta Orthop Scand 1966;37:29-48.
    • (1966) Acta Orthop Scand , vol.37 , pp. 29-48
    • Sedlin, E.D.1    Hirsch, C.2
  • 20
    • 0022628142 scopus 로고
    • Temperatures during drilling for the placement of implants using the osseointegration technique
    • Eriksson RA, Adell R. Temperatures during drilling for the placement of implants using the osseointegration technique. J Oral Maxillofac Surg 1986;44:4-7. (Pubitemid 16154442)
    • (1986) Journal of Oral and Maxillofacial Surgery , vol.44 , Issue.1 , pp. 4-7
    • Eriksson, R.A.1    Adell, R.2
  • 21
    • 0036974819 scopus 로고    scopus 로고
    • Histomorphometric and fluorescence microscopic analysis of bone remodelling after installation of implants using an osteotome technique
    • DOI 10.1034/j.1600-0501.2002.130604.x
    • Nkenke E, Kloss F, Wiltfang J, Schultze-Mosgau S, Radespiel-Tröger M, Loos K, et al. Histomorphometric and fluorescence microscopic analysis of bone remodeling after installation of implants using an osteotome technique. Clin Oral Implants Res 2002;13:595-602. (Pubitemid 41749846)
    • (2002) Clinical Oral Implants Research , vol.13 , Issue.6 , pp. 595-602
    • Nkenke, E.1    Kloss, F.2    Wiltfang, J.3    Schultze-Mosgau, S.4    Radespiel-Troger, M.5    Loos, K.6    Neukam, F.W.7
  • 22
    • 0015301831 scopus 로고
    • Temperatures measured in human cortical bone when drilling
    • Matthews LS, Hirsch C. Temperatures measured in human cortical bone when drilling. J Bone Joint Surg 1972;54:297-308.
    • (1972) J Bone Joint Surg , vol.54 , pp. 297-308
    • Matthews, L.S.1    Hirsch, C.2
  • 24
    • 0036780887 scopus 로고    scopus 로고
    • A prospective study evaluating a protocol for 6 weeks' loading of SLA implants in the posterior maxilla: One-year results
    • DOI 10.1034/j.1600-0501.2002.130509.x
    • Roccuzzo M, Wilson TG. A prospective study evaluating a protocol for 6 weeks' loading of SLA implants in the posterior maxilla. Clin Oral Implants Res 2002;13:502-7. (Pubitemid 41713076)
    • (2002) Clinical Oral Implants Research , vol.13 , Issue.5 , pp. 502-507
    • Roccuzzo, M.1    Wilson, T.G.2
  • 27
    • 0036779557 scopus 로고    scopus 로고
    • Peri-implant alveolar bone loss with respect to bone quality after use of the osteotome technique: Results of a retrospective study
    • DOI 10.1034/j.1600-0501.2002.130510.x
    • Strietzel FP, Nowak M, Kuchler I, Friedmann A. Peri-implant alveolar bone loss with respect to bone quality after use of the osteotome technique. Clin Oral Implants Res 2002;13:508-13. (Pubitemid 41713077)
    • (2002) Clinical Oral Implants Research , vol.13 , Issue.5 , pp. 508-513
    • Strietzel, F.P.1    Nowak, M.2    Kuchler, I.3    Friedmann, A.4
  • 28
    • 0022726532 scopus 로고
    • The long-term efficacy of currently used dental implants: A review and proposed criteria of success
    • Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.2    Worthington, P.3    Eriksson, A.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.