-
1
-
-
0024031111
-
A retrospective multicenter evaluation of osseointegrated implants supporting overdentures
-
Engquist B, Bergendal T, Kallus T, Linden U. A retrospective multicenter evaluation of osseointegrated implants supporting overdentures. Int J Oral Maxillofac Implants 1988;3:129-34.
-
(1988)
Int J Oral Maxillofac Implants
, vol.3
, pp. 129-134
-
-
Engquist, B.1
Bergendal, T.2
Kallus, T.3
Linden, U.4
-
2
-
-
0035490935
-
Optimal implant stabilization in low density bone
-
Martinez H, Davarpanah M, Missika P, Celletti R, Lazzara R. Optimal implant stabilization in low density bone. Clin Oral Implants Res 2001;12:423-32. (Pubitemid 33723178)
-
(2001)
Clinical Oral Implants Research
, vol.12
, Issue.5
, pp. 423-432
-
-
Martinez, H.1
Davarpanah, M.2
Missika, P.3
Celletti, R.4
Lazzara, R.5
-
3
-
-
0039184644
-
Density of bone: Effect on treatment, planning, surgical approach and healing
-
Misch C, editor. St. Louis: Mosby
-
Misch C. Density of bone: effect on treatment, planning, surgical approach and healing. In: Misch C, editor. Contemporary implant dentistry. St. Louis: Mosby; 1993. p. 469-84.
-
(1993)
Contemporary Implant Dentistry
, pp. 469-484
-
-
Misch, C.1
-
4
-
-
0028373728
-
A new concept in maxillary implant surgery: The osteotome technique
-
Summers RB. A new concept in maxillary implant surgery: the osteotome technique. Compend Contin Educ Dent 1994;15:152-60.
-
(1994)
Compend Contin Educ Dent
, vol.15
, pp. 152-160
-
-
Summers, R.B.1
-
5
-
-
0002455249
-
Bone tissue response
-
Branemark PI, Zarb GA, Albrektsson T, editors. Chicago: Quintessence Publishing
-
Albrektsson T. Bone tissue response. In: Branemark PI, Zarb GA, Albrektsson T, editors. Tissue integrated prosthesis: osseointegration in clinical dentistry. Chicago: Quintessence Publishing; 1985. p. 129-40.
-
(1985)
Tissue Integrated Prosthesis: Osseointegration in Clinical Dentistry
, pp. 129-140
-
-
Albrektsson, T.1
-
8
-
-
0020790218
-
Temperature threshold levels for heat-induced bone tissue injury: A vital microscopic study in the rabbit
-
Eriksson RA, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury: a vital microscopic study in the rabbit. J Prosthet Dent 1983;50:101-7.
-
(1983)
J Prosthet Dent
, vol.50
, pp. 101-107
-
-
Eriksson, R.A.1
Albrektsson, T.2
-
10
-
-
0027572074
-
The effect of temperature, stress and microstructure on the creep of compact bovine bone
-
DOI 10.1016/0021-9290(93)90360-Q
-
Rimnac CM, Pekto AA, Santner TJ, Wright TM. The effect of temperature, stress and microstructure on the creep of compact bovine bone. J Biomech 1993;26:219-28. (Pubitemid 23099393)
-
(1993)
Journal of Biomechanics
, vol.26
, Issue.3
, pp. 219-228
-
-
Rimnac, C.M.1
Petko, A.A.2
Santner, T.J.3
Wright, T.M.4
-
11
-
-
0031264521
-
Effects of Drill Speed on Heat Production and the Rate and Quality of Bone Formation in Dental Implant Osteotomies. Part II: Relationship between Drill Speed and Healing
-
Iyer S, Weiss C, Mehta A. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing. Int J Prosthodont 1997;10:536-40. (Pubitemid 127500363)
-
(1997)
International Journal of Prosthodontics
, vol.10
, Issue.6
, pp. 536-540
-
-
Iyer, S.1
Weiss, C.2
Mehta, A.3
-
12
-
-
0029683215
-
The Effect of Speed, Pressure, and Time on Bone Temperature during the Drilling of Implant Sites
-
Brisman DL. The effect of speed, pressure and time on bone temperature during the drilling of implant sites. Int J Oral Maxillofac Implants 1996;11:35-7. (Pubitemid 126442751)
-
(1996)
International Journal of Oral and Maxillofacial Implants
, vol.11
, Issue.1
, pp. 35-37
-
-
Brisman, D.L.1
-
14
-
-
30644469370
-
Heat production by 3 implant drill systems after repeated drilling and sterilization
-
DOI 10.1016/j.joms.2005.10.011, PII S0278239105016836
-
Chacon GE, Bower DL, Larsen PE, McGlumphy EA, Beck FM. Heat production by 3 implant drill systems after repeated drilling and sterilization. J Oral Maxillofac Surg 2006;64:265-9. (Pubitemid 43087788)
-
(2006)
Journal of Oral and Maxillofacial Surgery
, vol.64
, Issue.2
, pp. 265-269
-
-
Chacon, G.E.1
Bower, D.L.2
Larsen, P.E.3
McGlumphy, E.A.4
Beck, F.M.5
-
15
-
-
3042517588
-
The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: A study of drill durability
-
Ercoli C, Funkenbusch PD, Lee HJ, Moss ME, Graser GN. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. Int J Oral Maxillofac Implants 2004;19:335-49. (Pubitemid 38822321)
-
(2004)
International Journal of Oral and Maxillofacial Implants
, vol.19
, Issue.3
, pp. 335-349
-
-
Ercoli, C.1
Funkenbusch, P.D.2
Lee, H.-J.3
Moss, M.E.4
Graser, G.N.5
-
16
-
-
60049100274
-
Effects of irrigation temperature on heat control in vitro at different drilling depths
-
Sener BC, Dergin G, Gursoy B, Kelesoglu E, Slih I. Effects of irrigation temperature on heat control in vitro at different drilling depths. Clin Oral Implants Res 2009;20:294-8.
-
(2009)
Clin Oral Implants Res
, vol.20
, pp. 294-298
-
-
Sener, B.C.1
Dergin, G.2
Gursoy, B.3
Kelesoglu, E.4
Slih, I.5
-
18
-
-
0031763862
-
Interspecies differences in bone composition, density, and quality: Potential implications for in vivo bone research
-
DOI 10.1210/en.139.2.663
-
Aerssen J, Boonen S, Lowet G, Dequeker J. Interspecies differences in bone composition, density, and quality: potential applications for in vivo bone research. Endocrinology 1998;139:663-70. (Pubitemid 28513217)
-
(1998)
Endocrinology
, vol.139
, Issue.2
, pp. 663-670
-
-
Aerssens, J.1
Boonen, S.2
Lowet, G.3
Dequeker, J.4
-
19
-
-
0013864447
-
Factors affecting the determination of the physical properties of femoral cortical bone
-
Sedlin ED, Hirsch C. Factors affecting the determination of the physical properties of femoral cortical bone. Acta Orthop Scand 1966;37:29-48.
-
(1966)
Acta Orthop Scand
, vol.37
, pp. 29-48
-
-
Sedlin, E.D.1
Hirsch, C.2
-
20
-
-
0022628142
-
Temperatures during drilling for the placement of implants using the osseointegration technique
-
Eriksson RA, Adell R. Temperatures during drilling for the placement of implants using the osseointegration technique. J Oral Maxillofac Surg 1986;44:4-7. (Pubitemid 16154442)
-
(1986)
Journal of Oral and Maxillofacial Surgery
, vol.44
, Issue.1
, pp. 4-7
-
-
Eriksson, R.A.1
Adell, R.2
-
21
-
-
0036974819
-
Histomorphometric and fluorescence microscopic analysis of bone remodelling after installation of implants using an osteotome technique
-
DOI 10.1034/j.1600-0501.2002.130604.x
-
Nkenke E, Kloss F, Wiltfang J, Schultze-Mosgau S, Radespiel-Tröger M, Loos K, et al. Histomorphometric and fluorescence microscopic analysis of bone remodeling after installation of implants using an osteotome technique. Clin Oral Implants Res 2002;13:595-602. (Pubitemid 41749846)
-
(2002)
Clinical Oral Implants Research
, vol.13
, Issue.6
, pp. 595-602
-
-
Nkenke, E.1
Kloss, F.2
Wiltfang, J.3
Schultze-Mosgau, S.4
Radespiel-Troger, M.5
Loos, K.6
Neukam, F.W.7
-
22
-
-
0015301831
-
Temperatures measured in human cortical bone when drilling
-
Matthews LS, Hirsch C. Temperatures measured in human cortical bone when drilling. J Bone Joint Surg 1972;54:297-308.
-
(1972)
J Bone Joint Surg
, vol.54
, pp. 297-308
-
-
Matthews, L.S.1
Hirsch, C.2
-
23
-
-
17444397440
-
Biological and biomechanical evaluation of bone remodelling and implant stability after using an osteotome technique
-
DOI 10.1111/j.1600-0501.2004.01081.x
-
Büchter A, Kleinheinz J, Wiesmann HP, Kersken J, Nienkemper M, von Weyhrother H, et al. Biological and biomechanical evaluation of bone remodeling and implant stability after using an osteotome technique. Clin Oral Implants Res 2005;16:1-8. (Pubitemid 41595030)
-
(2005)
Clinical Oral Implants Research
, vol.16
, Issue.1
, pp. 1-8
-
-
Buchter, A.1
Kleinheinz, J.2
Wiesmann, H.P.3
Kersken, J.4
Nienkemper, M.5
Von Weyhrother, H.6
Joos, U.7
Meyer, U.8
-
24
-
-
0036780887
-
A prospective study evaluating a protocol for 6 weeks' loading of SLA implants in the posterior maxilla: One-year results
-
DOI 10.1034/j.1600-0501.2002.130509.x
-
Roccuzzo M, Wilson TG. A prospective study evaluating a protocol for 6 weeks' loading of SLA implants in the posterior maxilla. Clin Oral Implants Res 2002;13:502-7. (Pubitemid 41713076)
-
(2002)
Clinical Oral Implants Research
, vol.13
, Issue.5
, pp. 502-507
-
-
Roccuzzo, M.1
Wilson, T.G.2
-
27
-
-
0036779557
-
Peri-implant alveolar bone loss with respect to bone quality after use of the osteotome technique: Results of a retrospective study
-
DOI 10.1034/j.1600-0501.2002.130510.x
-
Strietzel FP, Nowak M, Kuchler I, Friedmann A. Peri-implant alveolar bone loss with respect to bone quality after use of the osteotome technique. Clin Oral Implants Res 2002;13:508-13. (Pubitemid 41713077)
-
(2002)
Clinical Oral Implants Research
, vol.13
, Issue.5
, pp. 508-513
-
-
Strietzel, F.P.1
Nowak, M.2
Kuchler, I.3
Friedmann, A.4
|