메뉴 건너뛰기




Volumn 79, Issue 1, 2011, Pages 113-117

Diffusion tensor imaging with cerebrospinal fluid suppression and signal-to-noise preservation using acquisition combining fluid-attenuated inversion recovery and conventional imaging: Comparison of fiber tracking

Author keywords

Cerebrospinal fluid; Diffusion tensor imaging; Fiber tractography; Fluid attenuated inversion recovery; Partial volume effects

Indexed keywords

ADULT; ARTICLE; CEREBROSPINAL FLUID; DIFFUSION TENSOR IMAGING; ECHO PLANAR IMAGING; ELECTRON SPIN RESONANCE; FEMALE; FIBER TRACTOGRAPHY; FLUID ATTENUATED INVERSION RECOVERY; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SIGNAL NOISE RATIO; TRACTOGRAPHY; WHITE MATTER;

EID: 79958768450     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2009.12.032     Document Type: Article
Times cited : (13)

References (20)
  • 1
    • 0036869232 scopus 로고    scopus 로고
    • Diffusion-tensor MRI: Theory, experimental design and data analysis - A technical review
    • DOI 10.1002/nbm.783
    • Basser PJ, Jones DK. Diffusion-tensor MRI: theory, experimental design and data analysis - a technical review. NMR Biomed 2002;15:456-67. (Pubitemid 36054509)
    • (2002) NMR in Biomedicine , vol.15 , Issue.7-8 , pp. 456-467
    • Basser, P.J.1    Jones, D.K.2
  • 2
    • 33845258553 scopus 로고    scopus 로고
    • High-resolution DTI of a localized volume using 3D single-shot diffusion-weighted stimulated echo-planar imaging (3D ss-DWSTEPI)
    • DOI 10.1002/mrm.21088
    • Jeong EK, Kim SE, Kholmovski EG, Parker DL. High-resolution DTI of a localized volume using 3D single-shot Diffusion-Weighted STimulated Echo-Planar Imaging (3D ss-DWSTEPI). Magn Reson Med 2006;56:1173-81. (Pubitemid 44865298)
    • (2006) Magnetic Resonance in Medicine , vol.56 , Issue.6 , pp. 1173-1181
    • Jeong, E.-K.1    Kim, S.-E.2    Kholmovski, E.G.3    Parker, D.L.4
  • 3
    • 33845234266 scopus 로고    scopus 로고
    • PROPELLER-EPI with parallel imaging using a circularly symmetric phased-array RF coil at 3.0 T: Application to high-resolution diffusion tensor imaging
    • Chuang TC, Huang TY, Lin FH, et al. PROPELLER-EPI with parallel imaging using a circularly symmetric phased-array RF coil at 3.0 T: application to high-resolution diffusion tensor imaging. Magn Reson Med 2006;56:1352-8.
    • (2006) Magn Reson Med , vol.56 , pp. 1352-1358
    • Chuang, T.C.1    Huang, T.Y.2    Lin, F.H.3
  • 4
    • 0036868732 scopus 로고    scopus 로고
    • Diffusion tensor fiber tracking of human brain connectivity: Acquisition methods, reliability analysis and biological results
    • Lori NF, Akbudak E, Shimony JS, et al. Diffusion tensor fiber tracking of human brain connectivity: aquisition methods, reliability analysis and biological results. NMR Biomed 2002;15:493-515. (Pubitemid 36054512)
    • (2002) NMR in Biomedicine , vol.15 , Issue.7-8 , pp. 493-515
    • Lori, N.F.1    Akbudak, E.2    Shimony, J.S.3    Snyder, A.Z.4    Guillory, R.K.5    Conturo, T.E.6
  • 6
    • 0036869345 scopus 로고    scopus 로고
    • Applications of diffusion-weighted and diffusion tensor MRI to white matter diseases - A review
    • DOI 10.1002/nbm.787
    • Horsfield MA, Jones DK. Applications of diffusion-weighted and diffusion tensor MRI to white matter diseases - a review. NMR Biomed 2002;15:570-7. (Pubitemid 36054517)
    • (2002) NMR in Biomedicine , vol.15 , Issue.7-8 , pp. 570-577
    • Horsfield, M.A.1    Jones, D.K.2
  • 7
    • 0036708128 scopus 로고    scopus 로고
    • Cerebral spinal fluid contamination of the measurement of the apparent diffusion coefficient of water in acute stroke
    • DOI 10.1002/mrm.10238
    • Latour LL, Warach S. Cerebral spinal fluid contamination of the measurement of the apparent diffusion coefficient of water in acute stroke. Magn Reson Med 2002;48:478-86. (Pubitemid 34951325)
    • (2002) Magnetic Resonance in Medicine , vol.48 , Issue.3 , pp. 478-486
    • Latour, L.L.1    Warach, S.2
  • 8
    • 0032984696 scopus 로고    scopus 로고
    • Comparison of diffusion anisotropy measurements in combination with the FLAIR-technique
    • DOI 10.1016/S0730-725X(98)00217-3, PII S0730725X98002173
    • Hirsch JG, Bock M, Essig M, Schad LR. Comparison of diffusion anisotropy measurements in combination with the flair-technique. Magn Reson Imaging 1999;17:705-16. (Pubitemid 29244806)
    • (1999) Magnetic Resonance Imaging , vol.17 , Issue.5 , pp. 705-716
    • Hirsch, J.G.1    Bock, M.2    Essig, M.3    Schad, L.R.4
  • 9
    • 0842328896 scopus 로고    scopus 로고
    • Enhancing Measured Diffusion Anisotropy in Gray Matter by Eliminating CSF Contamination with FLAIR
    • DOI 10.1002/mrm.10703
    • Ma XY, Kadah YM, LaConte SM, Hu XP. Enhancing measured diffusion anisotropy in gray matter by eliminating CSF contamination with FLAIR. Magn Reson Med 2004;51:423-7. (Pubitemid 38168606)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.2 , pp. 423-427
    • Ma, X.1    Kadah, Y.M.2    LaConte, S.M.3    Hu, X.4
  • 11
    • 16844366592 scopus 로고    scopus 로고
    • FLAIR diffusion-tensor MR tractography: Comparison of fiber tracking with conventional imaging
    • Chou MC, Lin YR, Huang TY, et al. FLAIR diffusion-tensor MR tractography: comparison of fiber tracking with conventional imaging. Am J Neuroradiol 2005;26:591-7.
    • (2005) Am J Neuroradiol , vol.26 , pp. 591-597
    • Chou, M.C.1    Lin, Y.R.2    Huang, T.Y.3
  • 12
    • 32944480067 scopus 로고    scopus 로고
    • Diffusion tensor tractography of the limbic system
    • Concha L, Gross DW, Beaulieu C. Diffusion tensor tractography of the limbic system. Am J Neuroradiol 2005;26:2267-74.
    • (2005) Am J Neuroradiol , vol.26 , pp. 2267-2274
    • Concha, L.1    Gross, D.W.2    Beaulieu, C.3
  • 14
    • 33746911119 scopus 로고    scopus 로고
    • Tensor deflection (TEND) tractography with adaptive subvoxel stepping
    • Chou MC, Wu ML, Chen CY, et al. Tensor deflection (TEND) tractography with adaptive subvoxel stepping. J Magn Reson Imaging 2006;24:451-8.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 451-458
    • Chou, M.C.1    Wu, M.L.2    Chen, C.Y.3
  • 15
    • 0345742636 scopus 로고    scopus 로고
    • Comprehensive Approach for Correction of Motion and Distortion in Diffusion-Weighted MRI
    • DOI 10.1002/mrm.10677
    • Rohde GK, Barnett AS, Basser PJ, Marenco S, Pierpaoli C. Comprehensive approach for correction of motion and distortion in diffusion-weighted MRI. Magn Reson Med 2004;51:103-14. (Pubitemid 38095707)
    • (2004) Magnetic Resonance in Medicine , vol.51 , Issue.1 , pp. 103-114
    • Rohde, G.K.1    Barnett, A.S.2    Basser, P.J.3    Marenco, S.4    Pierpaoli, C.5
  • 16
    • 16644362475 scopus 로고    scopus 로고
    • Fluid-attenuated inversion recovery preparation: Not an improvement over conventional diffusion-weighted imaging at 3T in acute ischemic stroke
    • Simon JE, Czechowsky DK, Hill MD, Harris AD, Buchan AM, Frayne R. Fluid-attenuated inversion recovery preparation: not an improvement over conventional diffusion-weighted imaging at 3 T in acute ischemic stroke. Am J Neuroradiol 2004;25:1653-8. (Pubitemid 44123686)
    • (2004) American Journal of Neuroradiology , vol.25 , Issue.10 , pp. 1653-1658
    • Simon, J.E.1    Czechowsky, D.K.2    Hill, M.D.3    Harris, A.D.4    Buchan, A.M.5    Frayne, R.6
  • 17
    • 0037094384 scopus 로고    scopus 로고
    • EZ-tracing: A new ready-to-use algorithm for magnetic resonance tractography
    • DOI 10.1016/S0165-0270(02)00039-0, PII S0165027002000390
    • Terajima K, Nakada T. EZ-tracing: a new ready-to-use algorithm for magnetic resonance tractography. J Neurosci Methods 2002;116:147-55. (Pubitemid 34619186)
    • (2002) Journal of Neuroscience Methods , vol.116 , Issue.2 , pp. 147-155
    • Terajima, K.1    Nakada, T.2
  • 18
    • 29444460978 scopus 로고    scopus 로고
    • Acute ischemic stroke: Accuracy of diffusion-weighted MR imaging - Effects of b value and cerebrospinal fluid suppression
    • DOI 10.1148/radiol.2381041113
    • Chen PE, Simon JE, Hill MD, et al. Acute ischemic stroke: accuracy of diffusion-weighted MR imaging - effects of b value and cerebrospinal fluid suppression. Radiology 2006;238:232-9. (Pubitemid 43010600)
    • (2006) Radiology , vol.238 , Issue.1 , pp. 232-239
    • Chen, P.E.1    Simon, J.E.2    Hill, M.D.3    Sohn, C.-H.4    Dickhoff, P.5    Morrish, W.F.6    Sevick, R.J.7    Frayne, R.8
  • 19
    • 0036040136 scopus 로고    scopus 로고
    • White matter and lesion T1 relaxation times increase in parallel and correlate with disability in multiple sclerosis
    • DOI 10.1007/s00415-002-0837-7
    • Parry A, Clare S, Jenkinson M, Smith S, Palace J, Matthews PM. White matter and lesion T1 relaxation times increase in parallel and correlate with disability in multiple sclerosis. J Neurol 2002;249:1279-86. (Pubitemid 35025108)
    • (2002) Journal of Neurology , vol.249 , Issue.9 , pp. 1279-1286
    • Parry, A.1    Clare, S.2    Jenkinson, M.3    Smith, S.4    Palace, J.5    Matthews, P.M.6
  • 20
    • 33748079135 scopus 로고    scopus 로고
    • Spatial resolution dependence of DTI tractography in human occipito-callosal region
    • DOI 10.1016/j.neuroimage.2006.06.006, PII S105381190600677X
    • Kim M, Ronen I, Ugurbil K, Kim DS. Spatial resolution dependence of DTI tractography in human occipito-callosal region. Neuroimage 2006;32:1243-9. (Pubitemid 44294777)
    • (2006) NeuroImage , vol.32 , Issue.3 , pp. 1243-1249
    • Kim, M.1    Ronen, I.2    Ugurbil, K.3    Kim, D.-S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.