메뉴 건너뛰기




Volumn , Issue , 2011, Pages 89-94

A novel approach in testing the accuracy of ECG compression using partial percentage RMS difference and dynamic time warping

Author keywords

Approximation error; Direct data compression; Dynamic programming; Dynamic time warping; ECG compression; Pattern recognition

Indexed keywords

ACCURACY TEST; APPROXIMATION ERRORS; COMPRESSION TECHNIQUES; DIRECT DATA COMPRESSION; DYNAMIC TIME WARPING; ECG COMPRESSION; ECG DATA; ECG RECORDING; ECG SIGNALS;

EID: 79958758311     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (6)

References (20)
  • 1
    • 24944569633 scopus 로고    scopus 로고
    • Improved modified AZTEC technique for ECG data compression: Effect of length of parabolic filter on reconstructed signal
    • DOI 10.1016/j.compeleceng.2005.02.002, PII S0045790605000625
    • Vinod Kumar, S.C. Saxena, V.K. Giri and Dilag Singh, Improved modified AZTEC technique for ECG data compression: Effect of length of parabolic filter on reconstructed signal, Computers and Electrical Engineering, Vol. 31, 2005, pp 334-344. (Pubitemid 41328536)
    • (2005) Computers and Electrical Engineering , vol.31 , Issue.4-5 , pp. 334-344
    • Kumar, V.1    Saxena, S.C.2    Giri, V.K.3    Singh, D.4
  • 3
    • 0030248358 scopus 로고    scopus 로고
    • Segmentation of digital signals based on estimated compression ratio
    • DOI 10.1109/10.532127
    • Antti Koski and Martti Juhola, Segmentation of Digital Signals Based on Estimated Compression Ratio, IEEE Transactions on Biomedical Engineering, Vol. 43, 1996, pp928-938. (Pubitemid 26282066)
    • (1996) IEEE Transactions on Biomedical Engineering , vol.43 , Issue.9 , pp. 928-938
    • Koski, A.1    Juhola, M.2
  • 6
    • 0031539302 scopus 로고    scopus 로고
    • ECG coding by wavelet-based linear prediction
    • DOI 10.1109/10.649997
    • A.G. Ramakrishnan and S. Saha, ECG Coding by Wavelet based Linear Prediction, IEEE Transactions on Biomedical Engineering, Vol. 44, 1997, pp 1253- 1261. (Pubitemid 27516415)
    • (1997) IEEE Transactions on Biomedical Engineering , vol.44 , Issue.12 , pp. 1253-1261
    • Ramakrishnan, A.G.1    Saha, S.2
  • 9
    • 32444446858 scopus 로고    scopus 로고
    • Direct data compression of ECG signal for telemedicine
    • DOI 10.1080/00319100500412337, PII H5011817648752
    • V. Kumar, S.C. Saxena and V.K. Giri, Direct Data Compression of ECG Signal for Telemedicine, International Journal of Systems Science,Vol.37, 2006,pp 45-63. (Pubitemid 43224160)
    • (2006) International Journal of Systems Science , vol.37 , Issue.1 , pp. 45-63
    • Kumar, V.1    Saxena, S.C.2    Giri, V.K.3
  • 10
    • 41149104813 scopus 로고    scopus 로고
    • An ECG signals compression method and its validation using NNs
    • DOI 10.1109/TBME.2008.918465
    • Catalina Monica Fira and Liviu Goras, An ECG Signals Compression Method and Its Validation Using NNs, IEEE Transactions on Biomedical Engineering, Vol. 44, 2008, pp 1319-1326. (Pubitemid 351440501)
    • (2008) IEEE Transactions on Biomedical Engineering , vol.55 , Issue.4 , pp. 1319-1326
    • Fira, C.M.1    Goras, L.2
  • 15
    • 27944503304 scopus 로고    scopus 로고
    • Dynamic time warping as a novel tool in pattern recognition of ECG changes in heart rhythm disturbances
    • IEEE Systems, Man and Cybernetics Society, Proceedings - 2005 International Conference on Systems, Man and Cybernetics
    • Volkan Tuzcu and Selman Nas, Dynamic Time Warping As a Novel Tool in Pattern Recognition of ECG Changes in Heart Rhythm, IEEE International Conference on Systems, Man and Cybernetics, Vol 5, 2005, pp 182-186. (Pubitemid 41674877)
    • (2005) Conference Proceedings - IEEE International Conference on Systems, Man and Cybernetics , vol.1 , pp. 182-186
    • Tuzcu, V.1    Nas, S.2
  • 18
    • 0031333323 scopus 로고    scopus 로고
    • A database for evaluation of algorithms for measurement of QT and other waveform intervals in the ECG
    • Pablo Laguna, Roger G. Mark, Ary Goldberger and George B. Moody, A Database for Evaluation of Algorithms for Measurement of QT and Other Waveform Intervals in the ECG, Computers in Cardiology, 1997, vol. 24, pp. 673-676.
    • (1997) Computers in Cardiology , vol.24 , pp. 673-676
    • Laguna, P.1    Mark, R.G.2    Goldberger, A.3    Moody, G.B.4
  • 19
    • 0026680017 scopus 로고
    • Testing results and derivation of minimum performance criteria for computerized ECG-analysis
    • C. Zywietz and D. Celikag, Testing Results and Derivation of Minimum Performance Criteria for Computerized ECG-Analysis, Computer in Cardiology, 1991, pp 97-100.
    • (1991) Computer in Cardiology , pp. 97-100
    • Zywietz, C.1    Celikag, D.2
  • 20
    • 0004300729 scopus 로고    scopus 로고
    • London England, Churchill Livingston
    • J. R. Hampton, The ECG in Practice, London England, Churchill Livingston, 1997, pp. 227.
    • (1997) The ECG in Practice , pp. 227
    • Hampton, J.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.