메뉴 건너뛰기




Volumn 50, Issue 15, 2011, Pages 2170-2176

Comments on "Accuracy of Raman lidar water vapor calibration and its applicability to long-term measurements"

Author keywords

[No Author keywords available]

Indexed keywords

EFFICIENCY; INCANDESCENT LAMPS; LIGHTING; OPTICAL RADAR; RADIOSONDES; TELESCOPES; WATER VAPOR;

EID: 79958739627     PISSN: 1559128X     EISSN: 15394522     Source Type: Journal    
DOI: 10.1364/AO.50.002170     Document Type: Review
Times cited : (27)

References (21)
  • 1
    • 65949088588 scopus 로고    scopus 로고
    • First-year operation of a new water vapor Raman lidar at the JPL table mountain facility, California
    • T. Leblanc, I. S. McDermid, and R. A. Aspey, "First-year operation of a new water vapor Raman lidar at the JPL Table Mountain Facility, California," J. Atmos. Ocean. Technol. 25, 1454-1462 (2008).
    • (2008) J. Atmos. Ocean. Technol. , vol.25 , pp. 1454-1462
    • Leblanc, T.1    McDermid, I.S.2    Aspey, R.A.3
  • 3
    • 0031422212 scopus 로고    scopus 로고
    • Analysis of long-term behavior of ultraviolet radiation measured by Robertson- Berger meters at 14 sites in the United States
    • E. C. Weatherhead, G. C. Tiao, G. C. Reinsel, J. E. Frederick, J. J. DeLuisi, D. Choi, and W.-K. Tam, "Analysis of long-term behavior of ultraviolet radiation measured by Robertson- Berger meters at 14 sites in the United States," J. Geophys Res. 102, 8737-8754 (1997).
    • (1997) J. Geophys Res. , vol.102 , pp. 8737-8754
    • Weatherhead, E.C.1    Tiao, G.C.2    Reinsel, G.C.3    Frederick, J.E.4    DeLuisi, J.J.5    Choi, D.6    Tam, W.-K.7
  • 5
    • 72049116802 scopus 로고    scopus 로고
    • What are the demands on an observational program to detect trends in upper tropospheric water vapor anticipated in the 21st century
    • R. Boers and E. Meijgaard, What are the demands on an observational program to detect trends in upper tropospheric water vapor anticipated in the 21st century, Geophys. Res. Lett. 36, L19806 (2009).
    • (2009) Geophys. Res. Lett. , vol.36
    • Boers, R.1    Meijgaard, E.2
  • 6
    • 60749098821 scopus 로고    scopus 로고
    • Accuracy of Raman lidar water vapor calibration and its applicability to long-term measurements
    • T. Leblanc and I. S. McDermid, "Accuracy of Raman lidar water vapor calibration and its applicability to long-term measurements," Appl. Opt., 47, 5592-5603 (2008).
    • (2008) Appl. Opt. , vol.47 , pp. 5592-5603
    • Leblanc, T.1    McDermid, I.S.2
  • 7
    • 0041828892 scopus 로고    scopus 로고
    • Examination of the traditional Raman lidar technique. I. Evaluating the temperature-dependent lidar equations
    • D. N Whiteman, "Examination of the traditional Raman lidar technique. I. Evaluating the temperature-dependent lidar equations," Appl. Opt. 42, 2571-2592 (2003).
    • (2003) Appl. Opt. , vol.42 , pp. 2571-2592
    • Whiteman, D.N.1
  • 8
    • 0042830941 scopus 로고    scopus 로고
    • Examination of the traditional Raman lidar technique. II. Evaluating the ratios for water vapor and aerosols
    • D. N. Whiteman, "Examination of the traditional Raman lidar technique. II. Evaluating the ratios for water vapor and aerosols," Appl. Opt. 42, 2593-2608 (2003).
    • (2003) Appl. Opt. , vol.42 , pp. 2593-2608
    • Whiteman, D.N.1
  • 9
    • 84893898149 scopus 로고    scopus 로고
    • Optronics Laboratories, 4632 36th Street Orlando, FL 32811 (personal communication, 2009)
    • Optronics Laboratories, 4632 36th Street Orlando, FL 32811 (personal communication, 2009).
  • 10
    • 0033176743 scopus 로고    scopus 로고
    • Influence of the photomultiplier tube spatial uniformity on lidar signals
    • V. Simeonov, G. Larcheveque, P. Quaglia, H. van den Bergh, B. Calpini, "Influence of the photomultiplier tube spatial uniformity on lidar signals," Appl. Opt. 38, 5186-5190 (1999). (Pubitemid 129308821)
    • (1999) Applied Optics , vol.38 , Issue.24 , pp. 5186-5190
    • Simeonov, V.1    Larcheveque, G.2    Quaglia, P.3    Van Den Bergh, H.4    Calpini, B.5
  • 17
    • 0005346556 scopus 로고    scopus 로고
    • Methodology for the independent calibration of raman backscatter water-vapor lidar systems
    • V. Sherlock, A. Hauchecorne, J. Lenoble, "Methodology for the independent calibration of Raman backscatter water-vapor lidar systems," Appl. Opt. 38, 5816-5837 (1999). (Pubitemid 129567833)
    • (1999) Applied Optics , vol.38 , Issue.27 , pp. 5816-5837
    • Sherlock, V.1    Hauchecorne, A.2    Lenoble, J.3
  • 18
    • 0001414654 scopus 로고    scopus 로고
    • Implementation and validation of a Raman lidar measurement of middle and upper tropospheric water vapor
    • V. Sherlock, A. Garnier, A. Hauchecorne, and P. Keckhut, "Implementation and validation of a Raman lidar measurement of middle and upper tropospheric water vapor," Appl. Opt. 38, 5838-5858 (1999).
    • (1999) Appl. Opt. , vol.38 , pp. 5838-5858
    • Sherlock, V.1    Garnier, A.2    Hauchecorne, A.3    Keckhut, P.4
  • 19
    • 49249098946 scopus 로고    scopus 로고
    • Validation of aura microwave limb sounder water vapor by balloonborne cryogenic frost point hygrometer measurements
    • H. Vömel, J. E. Barnes, R. N. Forno, M. Fujiwara, F. Hasebe, S. Iwasaki, "Validation of aura microwave limb sounder water vapor by balloonborne cryogenic frost point hygrometer measurements," J. Geophys. Res. D 112, D24S37 (2007).
    • (2007) J. Geophys. Res. D , vol.112
    • Vömel, H.1    Barnes, J.E.2    Forno, R.N.3    Fujiwara, M.4    Hasebe, F.5    Iwasaki, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.