메뉴 건너뛰기




Volumn 43, Issue , 2011, Pages 440-464

Proton therapy: Clinical gains through current and future treatment programs

Author keywords

[No Author keywords available]

Indexed keywords

COBALT 60; PROTON;

EID: 79958209727     PISSN: 00719676     EISSN: 16623789     Source Type: Book Series    
DOI: 10.1159/000322509     Document Type: Article
Times cited : (18)

References (22)
  • 3
    • 0021134641 scopus 로고
    • Compensating for heterogeneities in proton radiation therapy
    • Urie M, Goitein M, Wagner M: Compensating for heterogeneities in proton radiation therapy. Phys Med Biol 1984; 29: 553-566. (Pubitemid 14054632)
    • (1984) Physics in Medicine and Biology , vol.29 , Issue.5 , pp. 553-566
    • Urie, M.1    Goitein, M.2    Wagner, M.3
  • 6
    • 0021851642 scopus 로고
    • Calculation of the uncertainty in the dose delivered during radiation therapy
    • DOI 10.1118/1.595762
    • Goitein M: Calculation of the uncertainty in the dose delivered during radiation therapy. Med Phys 1985; 12: 608-612. (Pubitemid 15248417)
    • (1985) Medical Physics , vol.12 , Issue.5 , pp. 608-612
    • Goitein, M.1
  • 7
    • 0242298672 scopus 로고    scopus 로고
    • Optimization of Beam Parameters and Treatment Planning for Intensity Modulated Proton Therapy
    • Trofimov A, Bortfeld T: Optimization of Beam Parameters and Treatment Planning for Intensity Modulated Proton Therapy. Technol Cancer Res Treat 2003; 2: 437-444. (Pubitemid 37363000)
    • (2003) Technology in Cancer Research and Treatment , vol.2 , Issue.5 , pp. 437-444
    • Trofimov, A.1    Bortfeld, T.2
  • 8
    • 33645973559 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy, protons, and the risk of second cancers
    • Hall E: Intensity-modulated radiation therapy, protons, and the risk of second cancers. Int J Radiat Oncol Biol Phys 2006; 65: 1-7.
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 1-7
    • Hall, E.1
  • 9
    • 73649128300 scopus 로고    scopus 로고
    • A case study in proton pencil-beam scanning delivery
    • Kooy H, Clasie BM, Lu H-M, et al: A case study in proton pencil-beam scanning delivery. Int J Radiat Oncol Biol Phys 2010; 76: 624-630.
    • (2010) Int J Radiat Oncol Biol Phys , vol.76 , pp. 624-630
    • Kooy, H.1    Clasie, B.M.2    Lu, H.-M.3
  • 10
    • 0028891524 scopus 로고
    • The 200- MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realization
    • Pedroni E, Bacher R, Blattmann H, et al: The 200- MeV proton therapy project at the Paul Scherrer Institute: conceptual design and practical realization. Med Phys 1995; 22: 37-53.
    • (1995) Med Phys , vol.22 , pp. 37-53
    • Pedroni, E.1    Bacher, R.2    Blattmann, H.3
  • 12
    • 0037036516 scopus 로고    scopus 로고
    • Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation
    • DOI 10.1088/0031-9155/47/13/302, PII S0031915502342490
    • Bortfeld T, Jokivarsi K, Goitein M, Kung J, Jiang SB: Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. Phys Med Biol 2002; 47: 2203-20. (Pubitemid 34812201)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.13 , pp. 2203-2220
    • Bortfeld, T.1    Jokivarsi, K.2    Goitein, M.3    Kung, J.4    Jiang, S.B.5
  • 13
    • 36649034851 scopus 로고    scopus 로고
    • Target motion tracking with a scanned particle beam, target motion tracking with a scanned particle beam
    • Bert C, Saito N, Schmidt A, Chaudhri N, Schardt D, Rietzel E: Target motion tracking with a scanned particle beam, target motion tracking with a scanned particle beam. Med Phys 2007; 34: 4768-4771.
    • (2007) Med Phys , vol.34 , pp. 4768-4771
    • Bert, C.1    Saito, N.2    Schmidt, A.3    Chaudhri, N.4    Schardt, D.5    Rietzel, E.6
  • 15
    • 58149125638 scopus 로고    scopus 로고
    • Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning
    • Unkelbach J, Bortfeld T, Martin BC, Soukup M: Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning. Med Phys 2009; 36: 149-163.
    • (2009) Med Phys , vol.36 , pp. 149-163
    • Unkelbach, J.1    Bortfeld, T.2    Martin, B.C.3    Soukup, M.4
  • 16
    • 0030025292 scopus 로고    scopus 로고
    • Proton dose monitoring with PET: Quantitative studies in Lucite
    • DOI 10.1088/0031-9155/41/1/013
    • Oelfke U, Lam GKY, Atkins MS: Proton dose monitoring with PET: quantitative studies in Lucite. Phys Med Biol 1996; 41: 177-196. (Pubitemid 26034231)
    • (1996) Physics in Medicine and Biology , vol.41 , Issue.1 , pp. 177-196
    • Oelfke, U.1    Lam, G.K.Y.2    Atkins, M.S.3
  • 18
    • 33750744100 scopus 로고    scopus 로고
    • Prompt gamma measurements for locating the dose falloff region in the proton therapy
    • Min C-H, Kim CH, Youn M-Y, Kim J-W: Prompt gamma measurements for locating the dose falloff region in the proton therapy. Appl Phys Lett 2006; 89: 183517.
    • (2006) Appl Phys Lett , vol.89 , pp. 183517
    • Min, C.-H.1    Kim, C.H.2    Youn, M.-Y.3    Kim, J.-W.4
  • 19
    • 63649163681 scopus 로고    scopus 로고
    • Prompt gamma-ray emission from biological tissues during proton irradiation: A preliminary study
    • Polf JC, Peterson S, Ciangaru G, Gillin M, Beddar S: Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary study. Phys Med Biol 2009; 54: 731-743.
    • (2009) Phys Med Biol , vol.54 , pp. 731-743
    • Polf, J.C.1    Peterson, S.2    Ciangaru, G.3    Gillin, M.4    Beddar, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.