메뉴 건너뛰기




Volumn 5, Issue 2, 2011, Pages

Can volatile compounds in exhaled breath be used to monitor control in diabetes mellitus?

Author keywords

[No Author keywords available]

Indexed keywords

3 HYDROXYBUTYRIC ACID; ACETOACETIC ACID; ACETONE; ISOPRENE; KETONE; METHYL NITRATE; NITRIC ACID DERIVATIVE; UNCLASSIFIED DRUG; VOLATILE AGENT; 1,3 BUTADIENE DERIVATIVE; HEMITERPENE; PENTANE;

EID: 79958117288     PISSN: 17527155     EISSN: 17527163     Source Type: Journal    
DOI: 10.1088/1752-7155/5/2/022001     Document Type: Review
Times cited : (97)

References (59)
  • 1
    • 77954830051 scopus 로고    scopus 로고
    • Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes
    • Bergenstal R M et al 2010 Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes N. Engl. J. Med. 363 311-20
    • (2010) N. Engl. J. Med. , vol.363 , pp. 311-320
    • Bergenstal, R.M.1
  • 2
    • 67749084303 scopus 로고    scopus 로고
    • Modern-day clinical course of type 1 diabetes mellitus after 30 years' duration the diabetes control and complications trial/epidemiology of diabetes interventions and complications and Pittsburgh epidemiology of diabetes complications experience (1983-2005)
    • Nathan D M et al 2009 Modern-day clinical course of type 1 diabetes mellitus after 30 years' duration the diabetes control and complications trial/epidemiology of diabetes interventions and complications and Pittsburgh epidemiology of diabetes complications experience (1983-2005) Arch. Intern. Med. 169 1307-16
    • (2009) Arch. Intern. Med. , vol.169 , pp. 1307-1316
    • Nathan, D.M.1
  • 3
    • 79958135633 scopus 로고    scopus 로고
    • The National Information Centre Department of Health Accessed July 2010
    • The National Information Centre 2010 National Diabetes Audit Executive Summary. Department of Health http://www ic nhs uk/webfiles/Services/ NCASP/audits%20and%20reports/National-Diabetes -Audit-Executive-Summary-2008- 2009 pdf(Accessed July 2010)
    • (2010) National Diabetes Audit Executive Summary
  • 4
    • 34548297727 scopus 로고    scopus 로고
    • Diabetes care, glycemic control, and complications in children with type 1 diabetes from Asia and the Western Pacific Region
    • DOI 10.1016/j.jdiacomp.2006.04.005, PII S1056872706000511
    • Craig M E, Jones T W, Silink M and Ping Y J 2007 Diabetes care, glycemic control, and complications in children with type 1 diabetes from Asia and the Western Pacific Region J. Diabetes Complications 21 280-7 (Pubitemid 47348315)
    • (2007) Journal of Diabetes and its Complications , vol.21 , Issue.5 , pp. 280-287
    • Craig, M.E.1    Jones, T.W.2    Silink, M.3    Ping, Y.J.4
  • 6
    • 0035181624 scopus 로고    scopus 로고
    • Effect of short-term glucose control on glycemic thresholds for epinephrine and hypoglycemic symptoms
    • DOI 10.1210/jc.86.11.5471
    • Burge M R, Sobhy T A, Qualls C R and Schade D S 2001 Effect of short-term glucose control on glycemic thresholds for epinephrine and hypoglycemic symptoms J. Clin. Endocrinol. Metab. 86 5471-8 (Pubitemid 33070277)
    • (2001) Journal of Clinical Endocrinology and Metabolism , vol.86 , Issue.11 , pp. 5471-5478
    • Burge, M.R.1    Sobhy, T.A.2    Qualls, C.R.3    Schade, D.S.4
  • 9
    • 0029085936 scopus 로고
    • Needle phobia - A neglected diagnosis
    • Hamilton J G 1995 Needle phobia - a neglected diagnosis J. Fam. Pract. 41 169-75
    • (1995) J. Fam. Pract. , vol.41 , pp. 169-175
    • Hamilton, J.G.1
  • 10
    • 33846196842 scopus 로고
    • Determination of acetone in expired air
    • Hubbard R S 1920 Determination of acetone in expired air J. Biol. Chem. 43 57-65
    • (1920) J. Biol. Chem. , vol.43 , pp. 57-65
    • Hubbard, R.S.1
  • 11
    • 0343742253 scopus 로고
    • Acetone in the breath-a study of acetone exhalation in diabetic and nondiabetic human subjects
    • Henderson M J, Karger B A and Wrenshall G A 1952 Acetone in the breath-a study of acetone exhalation in diabetic and nondiabetic human subjects Diabetes 1 188-93
    • (1952) Diabetes , vol.1 , pp. 188-193
    • Henderson, M.J.1    Karger, B.A.2    Wrenshall, G.A.3
  • 13
    • 4344563940 scopus 로고    scopus 로고
    • Volatile metabolic monitoring of glycemic status in diabetes using electronic olfaction
    • DOI 10.1089/1520915041705992
    • Dalton P, Gelperin A and Preti G 2004 Volatile metabolic monitoring of glycemic status in diabetes using electronic olfaction Diabetes Technol. Ther. 6 534-44 (Pubitemid 39121382)
    • (2004) Diabetes Technology and Therapeutics , vol.6 , Issue.4 , pp. 534-544
    • Dalton, P.1    Gelperin, A.2    Preti, G.3
  • 14
    • 79951844780 scopus 로고    scopus 로고
    • Progress in SIFT-MS; breath analysis and other applications
    • Španěl P and Smith D 2011 Progress in SIFT-MS; breath analysis and other applications Mass Spectrom. Rev. 30 (2) 236-67
    • (2011) Mass Spectrom. Rev. , vol.30 , Issue.2 , pp. 236-267
    • Španěl, P.1    Smith, D.2
  • 17
    • 0033400713 scopus 로고    scopus 로고
    • Ketone bodies: A review of physiology, pathophysiology and application of monitoring to diabetes
    • Laffel L 1999 Ketone bodies: a review of physiology, pathophysiology and application of monitoring to diabetes Diabetes Metab. Res. Rev. 15 412-26 (Pubitemid 30066228)
    • (1999) Diabetes/Metabolism Research and Reviews , vol.15 , Issue.6 , pp. 412-426
    • Laffel, L.1
  • 19
    • 0031738158 scopus 로고    scopus 로고
    • The selected ion flow tube method for workplace analyses of trace gases in air and breath: Its scope, validation, and applications
    • PII S1047322X98001083
    • Smith D, Španěl P, Thompson J M, Rajan B, Cocker J and Rolfe C 1998 The selected ion flow tube method for workplace analyses of trace gases in air and breath: its scope, validation and applications Appl. Occup. Environ. Hyg. 13 817-23 (Pubitemid 28549881)
    • (1998) Applied Occupational and Environmental Hygiene , vol.13 , Issue.12 , pp. 817-823
    • Smith, D.1    Spanel, P.2    Thompson, J.M.3    Rajan, B.4    Cocker, J.5    Rolfe, P.6
  • 20
    • 17444399677 scopus 로고    scopus 로고
    • Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis
    • DOI 10.1002/mas.20033
    • Smith D and Španěl P 2005 Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis Mass Spectrom. Rev. 24 661-700 (Pubitemid 41615714)
    • (2005) Mass Spectrometry Reviews , vol.24 , Issue.5 , pp. 661-700
    • Smith, D.1    Spanel, P.2
  • 21
    • 10044271359 scopus 로고    scopus 로고
    • On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) - Medical applications, food control and environmental research
    • Lindinger W, Hansel A and Jordan A 1998 On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) - medical applications, food control and environmental research Int. J. Mass Spectrom. 173 191-241
    • (1998) Int. J. Mass Spectrom. , vol.173 , pp. 191-241
    • Lindinger, W.1    Hansel, A.2    Jordan, A.3
  • 22
    • 10044285921 scopus 로고    scopus 로고
    • Medical applications of proton transfer reaction-mass spectrometry: Ambient air monitoring and breath analysis
    • Lirk P, Bodrogi F and Rieder J 2004 Medical applications of proton transfer reaction-mass spectrometry: ambient air monitoring and breath analysis Int. J. Mass Spectrom. 239 221-6
    • (2004) Int. J. Mass Spectrom. , vol.239 , pp. 221-226
    • Lirk, P.1    Bodrogi, F.2    Rieder, J.3
  • 23
    • 77951794989 scopus 로고    scopus 로고
    • Si:WO3 sensors for highly selective detection of acetone for easy diagnosis of diabetes by breath analysis
    • Righettoni M, Tricoli A and Pratsinis S E 2010 Si:WO3 sensors for highly selective detection of acetone for easy diagnosis of diabetes by breath analysis Anal. Chem. 82 3581-7
    • (2010) Anal. Chem. , vol.82 , pp. 3581-3587
    • Righettoni, M.1    Tricoli, A.2    Pratsinis, S.E.3
  • 24
    • 79551672592 scopus 로고    scopus 로고
    • Trace species detection in the near infrared using Fourier transform broadband cavity enhanced absorption spectroscopy: Initial studies on potential breath analytes
    • Denzer W et al 2011 Trace species detection in the near infrared using Fourier transform broadband cavity enhanced absorption spectroscopy: initial studies on potential breath analytes Analyst 136 801-6
    • (2011) Analyst , vol.136 , pp. 801-806
    • Denzer, W.1
  • 26
    • 0037414543 scopus 로고    scopus 로고
    • On the mammalian acetone metabolism: From chemistry to clinical implications
    • DOI 10.1016/S0304-4165(03)00051-5
    • Kalapos M P 2003 On the mammalian acetone metabolism: from chemistry to clinical implications Biochim. Biophys. Acta Gen. Subj. 1621 122-39 (Pubitemid 36515094)
    • (2003) Biochimica et Biophysica Acta - General Subjects , vol.1621 , Issue.2 , pp. 122-139
    • Kalapos, M.P.1
  • 28
    • 0031819043 scopus 로고    scopus 로고
    • Exhaled isoprene and acetone in newborn infants and in children with diabetes mellitus
    • Nelson N, Lagesson V, Nosratabadi A R, Ludvigsson J and Tagesson C 1998 Exhaled isoprene and acetone in newborn infants and in children with diabetes mellitus Pediatr. Res. 44 363-7 (Pubitemid 28389992)
    • (1998) Pediatric Research , vol.44 , Issue.3 , pp. 363-367
    • Nelson, N.1    Lagesson, V.2    Nosratabadi, A.R.3    Ludvigsson, J.4    Tagesson, C.5
  • 29
    • 39749184136 scopus 로고    scopus 로고
    • An exploratory comparative study of volatile compounds in exhaled breath and emitted by skin using selected ion flow tube mass spectrometry
    • DOI 10.1002/rcm.3402
    • Turner C, Parekh B, Walton C, Španěl P, Smith D and Evans M 2008 An exploratory comparative study of volatile compounds in exhaled breath and emitted by skin using selected ion flow tube mass spectrometry Rapid Commun. Mass Spectrom. 22 526-32 (Pubitemid 351300587)
    • (2008) Rapid Communications in Mass Spectrometry , vol.22 , Issue.4 , pp. 526-532
    • Turner, C.1    Parekh, B.2    Walton, C.3    Spanel, P.4    Smith, D.5    Evans, M.6
  • 30
    • 68149136300 scopus 로고    scopus 로고
    • Breath acetone-aspects of normal physiology related to age and gender as determined in a PTR-MS study
    • Schwarz K et al 2009 Breath acetone-aspects of normal physiology related to age and gender as determined in a PTR-MS study J. Breath Res. 3 027003
    • (2009) J. Breath Res. , vol.3 , pp. 027003
    • Schwarz, K.1
  • 31
    • 33645835176 scopus 로고    scopus 로고
    • Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver
    • DOI 10.1152/japplphysiol.00868.2005
    • Anderson J C, Lamm W J E and Hlastala M P 2006 Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver J. Appl. Physiol. 100 880-9 (Pubitemid 43671544)
    • (2006) Journal of Applied Physiology , vol.100 , Issue.3 , pp. 880-889
    • Anderson, J.C.1    Lamm, W.J.E.2    Hlastala, M.P.3
  • 32
    • 84883604545 scopus 로고    scopus 로고
    • Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity
    • Wang T, Pysanenko A, Dryahina K, Španěl P and Smith D 2008 Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity J. Breath Res. 2 037013
    • (2008) J. Breath Res. , vol.2 , pp. 037013
    • Wang, T.1    Pysanenko, A.2    Dryahina, K.3    Španěl, P.4    Smith, D.5
  • 33
    • 40649098183 scopus 로고    scopus 로고
    • Selected ion flow tube mass spectrometry of 3-hydroxybutyric acid, acetone and other ketones in the headspace of aqueous solution and urine
    • Wang T, Španěl P and Smith D 2008 Selected ion flow tube mass spectrometry of 3-hydroxybutyric acid, acetone and other ketones in the headspace of aqueous solution and urine Int. J. Mass Spectrom. 272 78-85
    • (2008) Int. J. Mass Spectrom. , vol.272 , pp. 78-85
    • Wang, T.1    Španěl, P.2    Smith, D.3
  • 34
    • 78649872712 scopus 로고    scopus 로고
    • Accurate, reproducible measurement of acetone concentration in breath using selected ion flow tube-mass spectrometry
    • Dummer J F et al 2010 Accurate, reproducible measurement of acetone concentration in breath using selected ion flow tube-mass spectrometry J. Breath Res. 4 046001
    • (2010) J. Breath Res. , vol.4 , pp. 046001
    • Dummer, J.F.1
  • 36
    • 76649112772 scopus 로고    scopus 로고
    • Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps
    • Turner C, Walton C, Hoashi S and Evans M 2009 Breath acetone concentration decreases with blood glucose concentration in type I diabetes mellitus patients during hypoglycaemic clamps J. Breath Res. 3 045004
    • (2009) J. Breath Res. , vol.3 , pp. 045004
    • Turner, C.1    Walton, C.2    Hoashi, S.3    Evans, M.4
  • 37
    • 72349088828 scopus 로고    scopus 로고
    • A study on breath acetone in diabetic patients using a cavity ringdown breath analyzer: Exploring correlations of breath acetone with blood glucose and glycohemoglobin A1C
    • Wang C J, Mbi A and Shepherd M 2010 A study on breath acetone in diabetic patients using a cavity ringdown breath analyzer: exploring correlations of breath acetone with blood glucose and glycohemoglobin A1C IEEE Sens. J. 10 54-63
    • (2010) IEEE Sens. J. , vol.10 , pp. 54-63
    • Wang, C.J.1    Mbi, A.2    Shepherd, M.3
  • 38
    • 32044454428 scopus 로고    scopus 로고
    • Relationship between skin acetone and blood beta-hydroxybutyrate concentrations in diabetes
    • DOI 10.1016/j.cca.2005.09.016, PII S000989810500584X
    • Yamane N, Tsuda T, Nose K, Yamamoto A, Ishiguro H and Kondo T 2006 Relationship between skin acetone and blood beta-hydroxybutyrate concentrations in diabetes Clin. Chim. Acta 365 325-9 (Pubitemid 43196455)
    • (2006) Clinica Chimica Acta , vol.365 , Issue.1-2 , pp. 325-329
    • Yamane, N.1    Tsuda, T.2    Nose, K.3    Yamamoto, A.4    Ishiguro, H.5    Kondo, T.6
  • 39
    • 0017838293 scopus 로고
    • Isoprene, an endogenous constituent of human alveolar air with a diurnal pattern of excretion
    • Demaster E G and Nagasawa H T 1978 Isoprene, an endogenous constituent of human alveolar air with a diurnal pattern of excretion Life Sci. 22 91-8 (Pubitemid 8273195)
    • (1978) Life Sciences , vol.22 , Issue.1 , pp. 91-98
    • DeMaster, E.G.1    Nagasawa, H.T.2
  • 40
    • 18444383957 scopus 로고    scopus 로고
    • Potential applications of breath isoprene as a biomarker in modern medicine: A concise overview
    • DOI 10.1007/s00508-005-0336-9
    • Salerno-Kennedy R and Cashman K D 2005 Potential applications of breath isoprene as a biomarker in modern medicine: a concise overview Wien. Klin. Wochenschr. 117 180-6 (Pubitemid 40645909)
    • (2005) Wiener Klinische Wochenschrift , vol.117 , Issue.5-6 , pp. 180-186
    • Salerno-Kennedy, R.1    Cashman, K.D.2
  • 45
    • 29244462954 scopus 로고    scopus 로고
    • A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS)
    • DOI 10.1088/0967-3334/27/1/002, PII S0967333406052385
    • Turner C, Španěl P and Smith D 2006 A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS) Physiol. Meas. 27 13-22 (Pubitemid 41821600)
    • (2006) Physiological Measurement , vol.27 , Issue.1 , pp. 13-22
    • Turner, C.1    Spanel, P.2    Smith, D.3
  • 46
    • 76249132107 scopus 로고    scopus 로고
    • Isoprene levels in the exhaled breath of 200 healthy pupils within the age range 7-18 years studied using SIFT-MS
    • Smith D, Španěl P, Enderby B, Lenny W, Turner C and Davies S 2010 Isoprene levels in the exhaled breath of 200 healthy pupils within the age range 7-18 years studied using SIFT-MS J. Breath Res. 4 017101
    • (2010) J. Breath Res. , vol.4 , pp. 017101
    • Smith, D.1    Španěl, P.2    Enderby, B.3    Lenny, W.4    Turner, C.5    Davies, S.6
  • 47
    • 78049530453 scopus 로고    scopus 로고
    • Dynamic profiles of volatile organic compounds in exhaled breath as determined by a coupled PTR-MS/GC-MS study
    • King J et al 2010 Dynamic profiles of volatile organic compounds in exhaled breath as determined by a coupled PTR-MS/GC-MS study Physiol. Meas. 31 1169-84
    • (2010) Physiol. Meas. , vol.31 , pp. 1169-1184
    • King, J.1
  • 48
    • 68149091274 scopus 로고    scopus 로고
    • Endogenous volatile organic compounds in breath and blood of healthy volunteers: Examining breath analysis as a surrogate for blood measurements
    • O'Hara M E, Clutton-Brock T H, Green S and Mayhew C A 2009 Endogenous volatile organic compounds in breath and blood of healthy volunteers: examining breath analysis as a surrogate for blood measurements J. Breath Res. 3 027005
    • (2009) J. Breath Res. , vol.3 , pp. 027005
    • O'Hara, M.E.1    Clutton-Brock, T.H.2    Green, S.3    Mayhew, C.A.4
  • 49
    • 41049102556 scopus 로고    scopus 로고
    • Development of a protocol to measure volatile organic compounds in human breath: A comparison of rebreathing and on-line single exhalations using proton transfer reaction mass spectrometry
    • DOI 10.1088/0967-3334/29/3/003, PII S0967333408564008
    • O'Hara M E, O'Hehir S, Green S and Mayhew C A 2008 Development of a protocol to measure volatile organic compounds in human breath: a comparison of rebreathing and on-line single exhalations using proton transfer reaction mass spectrometry Physiol. Meas. 29 309-30 (Pubitemid 351423042)
    • (2008) Physiological Measurement , vol.29 , Issue.3 , pp. 309-330
    • O'Hara, M.E.1    O'Hehir, S.2    Green, S.3    Mayhew, C.A.4
  • 50
    • 67650076217 scopus 로고    scopus 로고
    • Improved predictive models for plasma glucose estimation from multi-linear regression analysis of exhaled volatile organic compounds
    • Lee J et al 2009 Improved predictive models for plasma glucose estimation from multi-linear regression analysis of exhaled volatile organic compounds J. Appl. Physiol. 107 155-60
    • (2009) J. Appl. Physiol. , vol.107 , pp. 155-160
    • Lee, J.1
  • 51
    • 77949866490 scopus 로고    scopus 로고
    • Automated needle trap heart-cut GC/MS and needle trap comprehensive two-dimensional GC/TOF-MS for breath gas analysis in the clinical environment
    • Mieth M et al 2010 Automated needle trap heart-cut GC/MS and needle trap comprehensive two-dimensional GC/TOF-MS for breath gas analysis in the clinical environment Anal. Chem. 82 2541-51
    • (2010) Anal. Chem. , vol.82 , pp. 2541-2551
    • Mieth, M.1
  • 52
    • 65249177702 scopus 로고    scopus 로고
    • Proton-transfer reaction mass spectrometry
    • Blake R S, Monks P S and Ellis A M 2009 Proton-transfer reaction mass spectrometry Chem. Rev. 109 861-96
    • (2009) Chem. Rev. , vol.109 , pp. 861-896
    • Blake, R.S.1    Monks, P.S.2    Ellis, A.M.3
  • 53
    • 33344466254 scopus 로고    scopus 로고
    • A general method for the calculation of absolute trace gas concentrations in air and breath from selected ion flow tube mass spectrometry data
    • Španěl P, Dryahina K and Smith D 2006 A general method for the calculation of absolute trace gas concentrations in air and breath from selected ion flow tube mass spectrometry data Int. J. Mass Spectrom. 249 230-9
    • (2006) Int. J. Mass Spectrom. , vol.249 , pp. 230-239
    • Španěl, P.1    Dryahina, K.2    Smith, D.3
  • 54
    • 59349111436 scopus 로고    scopus 로고
    • Ionic diffusion and mass discrimination effects in the new generation of short flow tube SIFT-MS instruments
    • Smith D, Pysanenko A and Španěl P 2009 Ionic diffusion and mass discrimination effects in the new generation of short flow tube SIFT-MS instruments Int. J. Mass Spectrom. 281 15-23
    • (2009) Int. J. Mass Spectrom. , vol.281 , pp. 15-23
    • Smith, D.1    Pysanenko, A.2    Španěl, P.3
  • 55
    • 77952882681 scopus 로고    scopus 로고
    • Repeatability of the measurement of exhaled volatile metabolites using selected ion flow tube mass spectrometry
    • Boshier P R, Marczin N and Hanna G B 2010 Repeatability of the measurement of exhaled volatile metabolites using selected ion flow tube mass spectrometry J. Am. Soc. Mass Spectrom. 21 1070-4
    • (2010) J. Am. Soc. Mass Spectrom. , vol.21 , pp. 1070-1074
    • Boshier, P.R.1    Marczin, N.2    Hanna, G.B.3
  • 56
    • 84974678877 scopus 로고    scopus 로고
    • Acetone, ammonia and hydrogen cyanide in exhaled breath of several volunteers aged 4-83 years
    • Španěl P, Dryahina K and Smith D 2007 Acetone, ammonia and hydrogen cyanide in exhaled breath of several volunteers aged 4-83 years J. Breath Res. 1 011001
    • (2007) J. Breath Res. , vol.1 , pp. 011001
    • Španěl, P.1    Dryahina, K.2    Smith, D.3
  • 57
    • 84974690927 scopus 로고    scopus 로고
    • Volatile metabolites in the exhaled breath of healthy volunteers: Their levels and distributions
    • Smith D, Turner C and Španěl P 2007 Volatile metabolites in the exhaled breath of healthy volunteers: their levels and distributions J. Breath Res. 1 014004
    • (2007) J. Breath Res. , vol.1 , pp. 014004
    • Smith, D.1    Turner, C.2    Španěl, P.3
  • 58
    • 77951794989 scopus 로고    scopus 로고
    • Si:WO3 sensors for highly selective detection of acetone for easy diagnosis of diabetes by breath analysis
    • Righettoni M, Tricoli A and Pratsinis S E 2010 Si:WO3 sensors for highly selective detection of acetone for easy diagnosis of diabetes by breath analysis Anal. Chem. 82 3581-7
    • (2010) Anal. Chem. , vol.82 , pp. 3581-3587
    • Righettoni, M.1    Tricoli, A.2    Pratsinis, S.E.3
  • 59
    • 0036177713 scopus 로고    scopus 로고
    • Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetyes mellitus
    • Sacks D B, Bruns D E, Goldstein D E, Maclaren N K, McDonald J M and Parrott M 2002 Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus Clin. Chem. 48 436-72 (Pubitemid 34174577)
    • (2002) Clinical Chemistry , vol.48 , Issue.3 , pp. 436-472
    • Sacks, D.B.1    Bruns, D.E.2    Goldstein, D.E.3    Maclaren, N.K.4    McDonald, J.M.5    Parrott, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.