메뉴 건너뛰기




Volumn 156, Issue 2, 2011, Pages 651-656

A microfluidic sensor based on ferromagnetic resonance induced in magnetic bead labels

Author keywords

Ferromagnetic resonance; Magnetic beads; Microfluidics; Sensors

Indexed keywords

BACKGROUND SIGNALS; BIOTINYLATIONS; DETECTION TECHNIQUE; FUNCTIONALIZED; MAGNETIC BEADS; MICRO-FLUIDIC SENSORS; MICROFLUIDIC CHIP; MICROWAVE SIGNALS; OUTPUT SIGNAL; PROTOTYPE DEVICES; SENSOR AREA; SLOTLINES;

EID: 79958091493     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.02.012     Document Type: Article
Times cited : (11)

References (18)
  • 1
    • 33645390387 scopus 로고    scopus 로고
    • Enzymatically-generated fluorescent detection in micro-channels with internal magnetic mixing for the development of parallel microfluidic ELISA
    • M. Herrmann, T. Veres, and M. Tabrizian Enzymatically-generated fluorescent detection in micro-channels with internal magnetic mixing for the development of parallel microfluidic ELISA Lab Chip 6 2006 555 560
    • (2006) Lab Chip , vol.6 , pp. 555-560
    • Herrmann, M.1    Veres, T.2    Tabrizian, M.3
  • 5
    • 0037094859 scopus 로고    scopus 로고
    • Single magnetic microsphere placement and detection on-chip using current line designs with integrated spin valve sensors: Biotechnological applications
    • D. Graham, H. Ferreira, J. Bernardo, P. Freitas, and J. Cabral Single magnetic microsphere placement and detection on-chip using current line designs with integrated spin valve sensors: Biotechnological applications J. Appl. Phys. 91 2002 7786 7788
    • (2002) J. Appl. Phys. , vol.91 , pp. 7786-7788
    • Graham, D.1    Ferreira, H.2    Bernardo, J.3    Freitas, P.4    Cabral, J.5
  • 7
    • 0038651216 scopus 로고    scopus 로고
    • Detection of single micron-sized magnetic bead and magnetic nanoparticles using spin valve sensors for biological applications
    • G. Li, V. Joshi, R. White, S. Wang, J. Kemp, C. Webb, R. Davis, and S. Sun Detection of single micron-sized magnetic bead and magnetic nanoparticles using spin valve sensors for biological applications J. Appl. Phys. 93 2003 7557 7559
    • (2003) J. Appl. Phys. , vol.93 , pp. 7557-7559
    • Li, G.1    Joshi, V.2    White, R.3    Wang, S.4    Kemp, J.5    Webb, C.6    Davis, R.7    Sun, S.8
  • 8
    • 24344440275 scopus 로고    scopus 로고
    • In situ detection of single micron-sized magnetic beads using magnetic tunnel junction sensors
    • W. Shen, X. Liu, D. Mazumdar, and G. Xiao In situ detection of single micron-sized magnetic beads using magnetic tunnel junction sensors Appl. Phys. Lett. 86 2005 253901 253903
    • (2005) Appl. Phys. Lett. , vol.86 , pp. 253901-253903
    • Shen, W.1    Liu, X.2    Mazumdar, D.3    Xiao, G.4
  • 10
    • 0242364773 scopus 로고    scopus 로고
    • Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors
    • J. Rife, M. Miller, P. Sheehan, C. Tamanaha, M. Tondra, and L. Whitman Design and performance of GMR sensors for the detection of magnetic microbeads in biosensors Sens. Actuators A 107 2003 209 218
    • (2003) Sens. Actuators A , vol.107 , pp. 209-218
    • Rife, J.1    Miller, M.2    Sheehan, P.3    Tamanaha, C.4    Tondra, M.5    Whitman, L.6
  • 11
    • 79956014947 scopus 로고    scopus 로고
    • Detection of a micronsized magnetic sphereusing a ring-shaped anisotropic magnetoresistance-based sensor: A model for a magnetoresistance-based biosensor
    • M. Miller, G. Prinz, S. Cheng, and S. Bounnak Detection of a micronsized magnetic sphereusing a ring-shaped anisotropic magnetoresistance-based sensor: a model for a magnetoresistance-based biosensor Appl. Phys. Lett. 81 2002 2211 2213
    • (2002) Appl. Phys. Lett. , vol.81 , pp. 2211-2213
    • Miller, M.1    Prinz, G.2    Cheng, S.3    Bounnak, S.4
  • 12
    • 79956052903 scopus 로고    scopus 로고
    • Detection of a single magnetic microbead using a miniaturized silicon Hall sensor
    • P. Besse, G. Boero, M. Demierre, V. Pott, and R. Popovic Detection of a single magnetic microbead using a miniaturized silicon Hall sensor Appl. Phys. Lett. 80 2002 4199 4201
    • (2002) Appl. Phys. Lett. , vol.80 , pp. 4199-4201
    • Besse, P.1    Boero, G.2    Demierre, M.3    Pott, V.4    Popovic, R.5
  • 13
  • 14
    • 44649116419 scopus 로고    scopus 로고
    • Ferromagnetic resonance detection for magnetic microbead sensors
    • S. Ghionea, P. Dhagat, and A. Jander Ferromagnetic resonance detection for magnetic microbead sensors IEEE Sens. J. 8 2008 896 902
    • (2008) IEEE Sens. J. , vol.8 , pp. 896-902
    • Ghionea, S.1    Dhagat, P.2    Jander, A.3
  • 17
    • 36149026274 scopus 로고
    • On the theory of ferromagnetic resonance absorption
    • C. Kittel On the theory of ferromagnetic resonance absorption Phys. Rev. 73 1948 155 161
    • (1948) Phys. Rev. , vol.73 , pp. 155-161
    • Kittel, C.1
  • 18
    • 63649135909 scopus 로고    scopus 로고
    • Technique for microfabrication of polymeric-based microchips from an SU-8 master with temperature-assisted vaporized organic solvent bonding
    • M.T. Koesdjojo, C.R. Koch, and V.T. Remcho Technique for microfabrication of polymeric-based microchips from an SU-8 master with temperature-assisted vaporized organic solvent bonding Anal. Chem. 81 2009 1652 1659
    • (2009) Anal. Chem. , vol.81 , pp. 1652-1659
    • Koesdjojo, M.T.1    Koch, C.R.2    Remcho, V.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.