메뉴 건너뛰기




Volumn 82, Issue 5, 2011, Pages

Development of a mobile magnetic resonance imaging system for outdoor tree measurements

Author keywords

[No Author keywords available]

Indexed keywords

CROSS SECTIONAL IMAGE; DIFFUSION CONSTANT; ELECTRICAL UNITS; OUTDOOR ENVIRONMENT; PROTON DENSITY; WATER FLOWS;

EID: 79958060927     PISSN: 00346748     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.3589854     Document Type: Article
Times cited : (47)

References (15)
  • 2
    • 0034971009 scopus 로고    scopus 로고
    • 10.1093/jexbot/52.356.641
    • W. Kckenberger, J. Exp. Bot. 52, 641 (2001). 10.1093/jexbot/52.356.641
    • (2001) J. Exp. Bot. , vol.52 , pp. 641
    • Kckenberger, W.1
  • 5
    • 33847654327 scopus 로고    scopus 로고
    • Intact plant MRI for the study of cell water relations, membrane permeability, cell-to-cell and long distance water transport
    • DOI 10.1093/jxb/erl157
    • H. Van As, J. Exp. Bot. 58, 743 (2007). 10.1093/jxb/erl157 (Pubitemid 46363171)
    • (2007) Journal of Experimental Botany , vol.58 , Issue.4 , pp. 743-756
    • Van As, H.1
  • 6
    • 20844450278 scopus 로고    scopus 로고
    • Use of magnetic resonance microscopy for the nondestructive observation of xylem cavitation caused by pine wilt disease
    • DOI 10.1094/PHYTO-95-0737
    • S. Utsuzawa, K. Fukuda, and D. Sakaue, Phytopathology, 95, 737 (2005). 10.1094/PHYTO-95-0737 (Pubitemid 40856525)
    • (2005) Phytopathology , vol.95 , Issue.7 , pp. 737-743
    • Utsuzawa, S.1    Fukuda, K.2    Sakaue, D.3
  • 9
    • 84889323555 scopus 로고    scopus 로고
    • in, edited by S. Stapf, and S.-I. Han (Wiley, New York)
    • K. Kose, in NMR Imaging in Chemical Engineering, edited by, S. Stapf, and, S.-I. Han, (Wiley, New York, 2006), p. 77.
    • (2006) NMR Imaging in Chemical Engineering , pp. 77
    • Kose, K.1
  • 12
    • 0034855134 scopus 로고    scopus 로고
    • Development of a 1.0 T MR microscope using a Nd-Fe-B permanent magnet
    • DOI 10.1016/S0730-725X(01)00400-3, PII S0730725X01004003
    • T. Haishi, T. Uematsu, Y. Matsuda, and K. Kose, Magn. Reson. Imaging 19, 875 (2001). 10.1016/S0730-725X(01)00400-3 (Pubitemid 32845956)
    • (2001) Magnetic Resonance Imaging , vol.19 , Issue.6 , pp. 875-880
    • Haishi, T.1    Uematsu, T.2    Matsuda, Y.3    Kose, K.4
  • 15
    • 33846804493 scopus 로고    scopus 로고
    • Development of a compact MRI system for measuring the trabecular bone microstructure of the finger
    • DOI 10.1002/mrm.21130
    • N. Iita, S. Handa, S. Tomiha, and K. Kose, Magn. Res. Med. 57, 272, (2007). 10.1002/mrm.21130 (Pubitemid 46214530)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.2 , pp. 272-277
    • Iita, N.1    Handa, S.2    Tomiha, S.3    Kose, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.