-
1
-
-
33646002469
-
Recommendation on a uniform bilirubin standard
-
Developed Jointly by AAP, CAP, AACC, and NIH
-
Recommendation on a uniform bilirubin standard. Clin Chem 1962, 8:405-407. Developed Jointly by AAP, CAP, AACC, and NIH.
-
(1962)
Clin Chem
, vol.8
, pp. 405-407
-
-
-
2
-
-
0037559236
-
-
National Institute of Standards and Technology, National Institute of Standards and Technology, Gaithersburg, MD
-
Certificate of Analysis: Standard Reference Material 916a, Bilirubin 2001, National Institute of Standards and Technology, National Institute of Standards and Technology, Gaithersburg, MD.
-
(2001)
Certificate of Analysis: Standard Reference Material 916a, Bilirubin
-
-
-
3
-
-
0022232029
-
Candidate reference method for determination of total bilirubin in serum: Development and validation
-
Doumas B.T., Poon P.K.C., Perry B.W., et al. Candidate reference method for determination of total bilirubin in serum: Development and validation. Clin Chem 1985, 31:1779-1789.
-
(1985)
Clin Chem
, vol.31
, pp. 1779-1789
-
-
Doumas, B.T.1
Poon, P.K.C.2
Perry, B.W.3
-
4
-
-
0037992088
-
Commercial bilirubin: A trinity of isomers
-
McDonagh A.F., Assisi F. Commercial bilirubin: A trinity of isomers. FEBS Lett 1971, 18:315-317.
-
(1971)
FEBS Lett
, vol.18
, pp. 315-317
-
-
McDonagh, A.F.1
Assisi, F.2
-
5
-
-
0015394313
-
The ready isomerization of bilirubin IX-α in aqueous solution
-
McDonagh A.F., Assisi F. The ready isomerization of bilirubin IX-α in aqueous solution. Biochem J 1971, 129:797-800.
-
(1971)
Biochem J
, vol.129
, pp. 797-800
-
-
McDonagh, A.F.1
Assisi, F.2
-
6
-
-
0003100676
-
Vereinfachte photometrische Methoden zur Bestimmung des Blutbllirubins
-
Jendrassik L., Grof P. Vereinfachte photometrische Methoden zur Bestimmung des Blutbllirubins. Biochimie 1938, Z297:81-89.
-
(1938)
Biochimie
, vol.Z297
, pp. 81-89
-
-
Jendrassik, L.1
Grof, P.2
-
8
-
-
0020700571
-
Assessment of the fundamental accuracy of the Jendrassik-Gróf total and direct bilirubin assays
-
Lo D.H., Wu T.-W. Assessment of the fundamental accuracy of the Jendrassik-Gróf total and direct bilirubin assays. Clin Chem 1983, 29:31-36.
-
(1983)
Clin Chem
, vol.29
, pp. 31-36
-
-
Lo, D.H.1
Wu, T.-W.2
-
9
-
-
0025084416
-
Molar absorptivities of bilirubin (NIST SRM 916a) and its neutral and alkaline azopigments
-
Doumas B.T., Perry B.W., McComb R.B., et al. Molar absorptivities of bilirubin (NIST SRM 916a) and its neutral and alkaline azopigments. Clin Chem 1990, 36:1698-1701.
-
(1990)
Clin Chem
, vol.36
, pp. 1698-1701
-
-
Doumas, B.T.1
Perry, B.W.2
McComb, R.B.3
-
10
-
-
0022208088
-
Chemical nature of a synthetic bilirubin conjugate and its reactivities in the total and direct reactions by the Jendrassik-Gróf method
-
Doumas B.T., Wu T.-W., Poon K.C.P. Chemical nature of a synthetic bilirubin conjugate and its reactivities in the total and direct reactions by the Jendrassik-Gróf method. Clin Chem 1985, 31:1677-1682.
-
(1985)
Clin Chem
, vol.31
, pp. 1677-1682
-
-
Doumas, B.T.1
Wu, T.-W.2
Poon, K.C.P.3
-
11
-
-
0003317773
-
Bilirubin determination in serum and urine
-
Michaelsson M. Bilirubin determination in serum and urine. Scand J Clin Lab Invest 1962, 13(suppl):56.
-
(1962)
Scand J Clin Lab Invest
, vol.13
, Issue.SUPPL.
, pp. 56
-
-
Michaelsson, M.1
-
12
-
-
0037945809
-
Liver function
-
W B Saunders, Philadelphia, PA, C.A. Burtis, E.R. Ashwood (Eds.)
-
Tolman K.G., Rej R. Liver function. Tietz Textbook of Clinical Chemistry 1999, 1171. W B Saunders, Philadelphia, PA. (ed 3). C.A. Burtis, E.R. Ashwood (Eds.).
-
(1999)
Tietz Textbook of Clinical Chemistry
, pp. 1171
-
-
Tolman, K.G.1
Rej, R.2
-
13
-
-
0015918877
-
Spectral characteristics of bilirubin-bovine albumin complexes
-
Wennberg R.P., Cowger M.L. Spectral characteristics of bilirubin-bovine albumin complexes. Clin Chim Acta 1973, 43:55-64.
-
(1973)
Clin Chim Acta
, vol.43
, pp. 55-64
-
-
Wennberg, R.P.1
Cowger, M.L.2
-
14
-
-
1642467891
-
The effect of protein base on the molar absorptivity and the absorption spectra of unconjugated bilirubin
-
Doumas B.T., Perry B.W., Sasse E.A. The effect of protein base on the molar absorptivity and the absorption spectra of unconjugated bilirubin. Clin Chem 1973, 19:647.
-
(1973)
Clin Chem
, vol.19
, pp. 647
-
-
Doumas, B.T.1
Perry, B.W.2
Sasse, E.A.3
-
15
-
-
0020334617
-
The Kodak Ektachem clinical chemistry slide for measurement of bilirubin in newborns: Principles and performance
-
Wu T.-W., Dappen G.M., Powers D.M., et al. The Kodak Ektachem clinical chemistry slide for measurement of bilirubin in newborns: Principles and performance. Clin Chem 1982, 28:2366-2372.
-
(1982)
Clin Chem
, vol.28
, pp. 2366-2372
-
-
Wu, T.-W.1
Dappen, G.M.2
Powers, D.M.3
-
16
-
-
0022871269
-
Measurement of total bilirubin by use of bilirubin oxidase
-
Perry B., Doumas B.T., Buffone G., et al. Measurement of total bilirubin by use of bilirubin oxidase. Clin Chem 1986, 32:329-332.
-
(1986)
Clin Chem
, vol.32
, pp. 329-332
-
-
Perry, B.1
Doumas, B.T.2
Buffone, G.3
-
17
-
-
0023543350
-
Enzymatic determination of bilirubin fractions in serum
-
Kosaka A., Yamamoto C., Morishita Y., et al. Enzymatic determination of bilirubin fractions in serum. Clin Biochem 1987, 20:451-458.
-
(1987)
Clin Biochem
, vol.20
, pp. 451-458
-
-
Kosaka, A.1
Yamamoto, C.2
Morishita, Y.3
-
18
-
-
0023631916
-
Measurement of direct bilirubin by use of bilirubin oxidase
-
Doumas B.T., Perry B., Jendrzejczak B., et al. Measurement of direct bilirubin by use of bilirubin oxidase. Clin Chem 1987, 33:1349-1353.
-
(1987)
Clin Chem
, vol.33
, pp. 1349-1353
-
-
Doumas, B.T.1
Perry, B.2
Jendrzejczak, B.3
-
19
-
-
0032880569
-
Determination of the sum of bilirubin sugar conjugates in plasma by bilirubin oxidase
-
Doumas B.T., Yein F., Perry B., et al. Determination of the sum of bilirubin sugar conjugates in plasma by bilirubin oxidase. Clin Chem 1999, 45:1255-1260.
-
(1999)
Clin Chem
, vol.45
, pp. 1255-1260
-
-
Doumas, B.T.1
Yein, F.2
Perry, B.3
-
20
-
-
0019767286
-
-
Separation of bilirubin species in serum and bile by high-performance reversed-phase liquid chromatography. J Chromatogr 226
-
Lauff JJ, Kasper ME, Ambrose RT: Separation of bilirubin species in serum and bile by high-performance reversed-phase liquid chromatography. J Chromatogr 226:391-402,.
-
-
-
Lauff, J.J.1
Kasper, M.E.2
Ambrose, R.T.3
-
21
-
-
0023956550
-
Clinical application of serum bilirubin fractionation by simplified liquid chromatography
-
Adachi Y., Inufusa H., Yamashita M., et al. Clinical application of serum bilirubin fractionation by simplified liquid chromatography. Clin Chem 1988, 34:385-388.
-
(1988)
Clin Chem
, vol.34
, pp. 385-388
-
-
Adachi, Y.1
Inufusa, H.2
Yamashita, M.3
-
22
-
-
0018884030
-
Transcutaneous bilirubinometry: preliminary studies of noninvasive transcutaneous bilirubin meter in the Okayama National Hospital
-
Yamanouchi I., Yamauchi Y., Igarashi I. Transcutaneous bilirubinometry: preliminary studies of noninvasive transcutaneous bilirubin meter in the Okayama National Hospital. Pediatrics 1980, 65:195-202.
-
(1980)
Pediatrics
, vol.65
, pp. 195-202
-
-
Yamanouchi, I.1
Yamauchi, Y.2
Igarashi, I.3
-
23
-
-
79957940755
-
Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia
-
Bhutani V.K., Gourley G.R., Adler S., et al. Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia. Pediatrics 1999, 103:6-14.
-
(1999)
Pediatrics
, vol.103
, pp. 6-14
-
-
Bhutani, V.K.1
Gourley, G.R.2
Adler, S.3
-
24
-
-
0036178755
-
Improved transcutaneous bilirubinometry: comparison of SpectR(X) BiliCheck and Minolta Jaundice Meter JM-102 for estimating total serum bilirubin in a normal newborn population
-
Robertson A., Kazmierczak S., Vos P. Improved transcutaneous bilirubinometry: comparison of SpectR(X) BiliCheck and Minolta Jaundice Meter JM-102 for estimating total serum bilirubin in a normal newborn population. J Perinatol 2002, 22:12-14.
-
(2002)
J Perinatol
, vol.22
, pp. 12-14
-
-
Robertson, A.1
Kazmierczak, S.2
Vos, P.3
-
25
-
-
77954314332
-
Bilichek transcutaneous bilirubin meter overestimates serum bilirubin as measured by the Doumas reference method
-
Karon B.S., Wickremasinghe A.C., Lo S.F., et al. Bilichek transcutaneous bilirubin meter overestimates serum bilirubin as measured by the Doumas reference method. Clin Biochem 2010, 43:1009-1012.
-
(2010)
Clin Biochem
, vol.43
, pp. 1009-1012
-
-
Karon, B.S.1
Wickremasinghe, A.C.2
Lo, S.F.3
-
26
-
-
67650088581
-
Hyperbilirubinemia and transcutaneous bilirubinometry
-
El-Beshbishi S.N., Shattuck K.E., Mohammad A.A., et al. Hyperbilirubinemia and transcutaneous bilirubinometry. Clin Chem 2009, 55:1280-1287.
-
(2009)
Clin Chem
, vol.55
, pp. 1280-1287
-
-
El-Beshbishi, S.N.1
Shattuck, K.E.2
Mohammad, A.A.3
-
27
-
-
0020454941
-
Pitfalls in the American Monitor kit methods for determination of total and "direct" bilirubin
-
Doumas B.T., Perry B.W., Jendrzejczak B., et al. Pitfalls in the American Monitor kit methods for determination of total and "direct" bilirubin. Clin Chem 1982, 28:2305-2308.
-
(1982)
Clin Chem
, vol.28
, pp. 2305-2308
-
-
Doumas, B.T.1
Perry, B.W.2
Jendrzejczak, B.3
-
28
-
-
7444271381
-
Bilirubin proficiency testing using specimens containing unconjugated bilirubin and human serum: results of a College of American Pathologists study
-
Lo S.F., Doumas B.T., Ashwood E.R. Bilirubin proficiency testing using specimens containing unconjugated bilirubin and human serum: results of a College of American Pathologists study. Arch Pathol Lab Med 2004, 128:1219-1223.
-
(2004)
Arch Pathol Lab Med
, vol.128
, pp. 1219-1223
-
-
Lo, S.F.1
Doumas, B.T.2
Ashwood, E.R.3
-
29
-
-
55549097802
-
Laboratory performance in neonatal bilirubin testing using commutable specimens: a progress report on a College of American Pathologists study
-
Lo S.F., Jendrzejczak B., Doumas B.T. Laboratory performance in neonatal bilirubin testing using commutable specimens: a progress report on a College of American Pathologists study. Arch Pathol Lab Med 2008, 132:1781-1785.
-
(2008)
Arch Pathol Lab Med
, vol.132
, pp. 1781-1785
-
-
Lo, S.F.1
Jendrzejczak, B.2
Doumas, B.T.3
-
30
-
-
1642533460
-
Performance of bilirubin determinations in US laboratories--revisited
-
Lo S.F., Doumas B.T., Ashwood E.R. Performance of bilirubin determinations in US laboratories--revisited. Clin Chem 2004, 50:190-194.
-
(2004)
Clin Chem
, vol.50
, pp. 190-194
-
-
Lo, S.F.1
Doumas, B.T.2
Ashwood, E.R.3
-
31
-
-
79957951327
-
Pitfalls in the measurement of neonatal bilirubin
-
The 2008 AACC Annual Meeting, Washington, DC, July 20-24
-
Lo S.F., Schneider R., Jendrzejczak B., et al. Pitfalls in the measurement of neonatal bilirubin. Clin Chem 2008, 54:A229. The 2008 AACC Annual Meeting, Washington, DC, July 20-24.
-
(2008)
Clin Chem
, vol.54
-
-
Lo, S.F.1
Schneider, R.2
Jendrzejczak, B.3
-
32
-
-
77951713702
-
Bovine serum-based bilirubin calibrators are inappropriate for some diazo methods
-
Lo S.F., Jendrzejczak B., Doumas B.T. Bovine serum-based bilirubin calibrators are inappropriate for some diazo methods. Clin Chem 2010, 56:869-872.
-
(2010)
Clin Chem
, vol.56
, pp. 869-872
-
-
Lo, S.F.1
Jendrzejczak, B.2
Doumas, B.T.3
-
33
-
-
0030162567
-
Errors in measurement of total bilirubin: A perennial problem
-
Doumas B.T., Eckfeldt J.H. Errors in measurement of total bilirubin: A perennial problem. Clin Chem 1996, 42:845-848.
-
(1996)
Clin Chem
, vol.42
, pp. 845-848
-
-
Doumas, B.T.1
Eckfeldt, J.H.2
-
34
-
-
0015667688
-
Standardization in bilirubin assays: evaluation of selected methods and stability of bilirubin solutions
-
Doumas B.T., Perry B.W., Sasse E.A., et al. Standardization in bilirubin assays: evaluation of selected methods and stability of bilirubin solutions. Clin Chem 1973, 19:984-993.
-
(1973)
Clin Chem
, vol.19
, pp. 984-993
-
-
Doumas, B.T.1
Perry, B.W.2
Sasse, E.A.3
|