Volumn 21, Issue 3 PART 2, 2011, Pages 1430-1433
|
Breakdown characteristics of liquefied SF6 and CF4 gases in liquid nitrogen for high voltage bushings in a cryogenic environment
|
Author keywords
Breakdown; Bushing; CF4; High voltage; HTS electrical equipment; Liquefaction; LN2; Partial discharge; SF6
|
Indexed keywords
BREAKDOWN;
CF4;
ELECTRICAL EQUIPMENT;
HIGH VOLTAGE;
LN2;
SF6;
BUSHINGS;
CRYOGENICS;
ELECTRIC PROPERTIES;
ELECTRICITY;
GASES;
HIGH TEMPERATURE SUPERCONDUCTORS;
LIQUID NITROGEN;
LIQUIDS;
LOW TEMPERATURE ENGINEERING;
NITROGEN;
PARTIAL DISCHARGES;
SULFUR HEXAFLUORIDE;
SUPERCONDUCTING DEVICES;
SUPERCONDUCTIVITY;
TAPES;
LIQUEFACTION OF GASES;
|
EID: 79957912649
PISSN: 10518223
EISSN: None
Source Type: Journal
DOI: 10.1109/TASC.2010.2090638 Document Type: Article |
Times cited : (25)
|
References (8)
|