메뉴 건너뛰기




Volumn , Issue , 2011, Pages 359-362

Personalised mechatronic valve time-schedule optimiser for hydrocephalus shunt

Author keywords

[No Author keywords available]

Indexed keywords

BRAIN DAMAGE; CEREBRO SPINAL FLUIDS; CURRENT DIFFERENTIAL; DIFFERENTIAL PRESSURES; DYNAMICS MODELS; HYDROCEPHALUS SHUNTS; PRESSURE DEPENDENT; SHUNT VALVES; TIME SCHEDULES;

EID: 79957884912     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MECBME.2011.5752140     Document Type: Conference Paper
Times cited : (1)

References (7)
  • 1
    • 77951015031 scopus 로고    scopus 로고
    • United States Patent, No. 6926691
    • C. Miethke, "Hydrocephalus Valve", United States Patent, No. 6926691, 2005.
    • (2005) Hydrocephalus Valve
    • Miethke, C.1
  • 3
    • 11044233150 scopus 로고    scopus 로고
    • A model of in-vivo hydrocephalus shunt dynamics for blockage and performance diagnostics
    • D. Schley, J. Billingham and R. Marchbanks, "A model of in-vivo hydrocephalus shunt dynamics for blockage and performance diagnostics", Mathematical Medicine and Biology, vol. 21, 2004, pp 347-368. (Pubitemid 40044894)
    • (2004) Mathematical Medicine and Biology , vol.21 , Issue.4 , pp. 347-368
    • Schley, D.1    Billingham, J.2    Marchbanks, R.J.3
  • 4
    • 62849089600 scopus 로고    scopus 로고
    • Assessing the prediction potential of an in silico computer model of intracranial pressure dynamics
    • W. Wakeland, R. Agbeko, K. Vinecore, M. Peters and B. Goldstein, "Assessing the Prediction Potential of an in Silico Computer Model of Intracranial Pressure Dynamics", Critical Care Medicine, vol. 37, 2009, pp 1079-1089.
    • (2009) Critical Care Medicine , vol.37 , pp. 1079-1089
    • Wakeland, W.1    Agbeko, R.2    Vinecore, K.3    Peters, M.4    Goldstein, B.5
  • 5
    • 29144479817 scopus 로고    scopus 로고
    • Management of patients with normal pressure hydrocephalus by using lumboperitoneal shunt system with the Codman Hakim programmable valve: 6 years of clinical experience
    • N. Kuwana, C. Chang, S. Ito and T. Yokoyama, "Management of patients with normal pressure hydrocephalus by using lumboperitoneal shunt system with the Codman Hakim programmable valve: 6 years of clinical experience", International Congress Series,vol. 1247, 2009, pp 511-517.
    • (2009) International Congress Series , vol.1247 , pp. 511-517
    • Kuwana, N.1    Chang, C.2    Ito, S.3    Yokoyama, T.4
  • 6
    • 33947538321 scopus 로고    scopus 로고
    • Estimation of hidden state variables of the intracranial system using constrained nonlinear Kalman filters
    • DOI 10.1109/TBME.2006.890130, 5
    • X. Hu,V. Nenov, M. Bergsneider, TC Glenn, P Vespa, N Martin, "Estimation of hidden state variables of the intracranial system using constrained nonlinear Kalman filters", IEEE Transactions on Biomedical Engineering, vol. 54, 2007, pp 597-610. (Pubitemid 46469935)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.4 , pp. 597-610
    • Hu, X.1    Nenov, V.2    Bergsneider, M.3    Glenn, T.C.4    Vespa, P.5    Martin, N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.