메뉴 건너뛰기




Volumn 25, Issue 6, 2011, Pages 340-346

Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: A biomechanical study

Author keywords

angle stable locking; biomechanical study; Distal tibia fracture; intramedullary nail; unstable fracture

Indexed keywords

ADULT; AGED; ARTICLE; BIOMECHANICS; BONE DENSITY; BONE SCREW; CONTROLLED STUDY; DISTAL TIBIA FRACTURE; FEMALE; HUMAN; HUMAN CELL; INTRAMEDULLARY NAIL; INTRAMEDULLARY NAILING; LOAD CARRYING CAPACITY; LOCKING BONE SCREW; MALE; MECHANICAL STRESS; MECHANICAL TORSION; PRIORITY JOURNAL; RIGIDITY; SIMULATION; THICKNESS; TRABECULAR BONE;

EID: 79957842666     PISSN: 08905339     EISSN: 15312291     Source Type: Journal    
DOI: 10.1097/BOT.0b013e3182163345     Document Type: Article
Times cited : (64)

References (41)
  • 3
    • 0025116863 scopus 로고
    • Successful use of reaming and intramedullary nailing of the tibia
    • Collins DN, Pearce CE, McAndrew MP. Successful use of reaming and intramedullary nailing of the tibia. J Orthop Trauma. 1990;4:315-322.
    • (1990) J. Orthop. Trauma. , vol.4 , pp. 315-322
    • Collins, D.N.1    Pearce, C.E.2    McAndrew, M.P.3
  • 4
    • 1242320979 scopus 로고    scopus 로고
    • Reamed intramedullary tibial nailing: An overview and analysis of 1106 cases
    • DOI 10.1097/00005131-200402000-00007
    • Court-Brown CM. Reamed intramedullary tibial nailing: an overview and analysis of 1106 cases. J Orthop Trauma. 2004;18:96-101. (Pubitemid 38228573)
    • (2004) Journal of Orthopaedic Trauma , vol.18 , Issue.2 , pp. 96-101
    • Court-Brown, C.M.1
  • 6
    • 0028049378 scopus 로고
    • Treatment of grade IIIb open tibial fractures. A prospective randomised comparison of external fixation and non-reamed locked nailing
    • Tornetta P 3rd, Bergman M, Watnik N, et al. Treatment of grade-IIIb open tibial fractures. A prospective randomised comparison of external fixation and non-reamed locked nailing. J Bone Joint Surg Br. 1994;76:13-19. (Pubitemid 24029251)
    • (1994) Journal of Bone and Joint Surgery - Series B , vol.76 , Issue.1 , pp. 13-19
    • Tornetta III, P.1    Bergman, M.2    Watnik, N.3    Berkowitz, G.4    Steuer, J.5
  • 7
    • 0026476241 scopus 로고
    • Treatment of open fractures of the tibial shaft with the use of interlocking nailing without reaming
    • Whittle AP, Russell TA, Taylor JC, et al. Treatment of open fractures of the tibial shaft with the use of interlocking nailing without reaming. J Bone Joint Surg Am. 1992;74:1162-1171.
    • (1992) J. Bone Joint Surg. Am. , vol.74 , pp. 1162-1171
    • Whittle, A.P.1    Russell, T.A.2    Taylor, J.C.3
  • 9
    • 30344451992 scopus 로고    scopus 로고
    • Distal metaphyseal fractures of tibia: A prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation
    • discussion 1223
    • Im GI, Tae SK. Distal metaphyseal fractures of tibia: a prospective randomized trial of closed reduction and intramedullary nail versus open reduction and plate and screws fixation. J Trauma. 2005;59:1219-1223; discussion 1223.
    • (2005) J. Trauma. , vol.59 , pp. 1219-1223
    • Im, G.I.1    Tae, S.K.2
  • 10
    • 35348834164 scopus 로고    scopus 로고
    • Treatment of distal tibial fractures: Plate versus nail: A retrospective outcome analysis of matched pairs of patients
    • DOI 10.1007/s00264-006-0237-1
    • Janssen KW, Biert J, van Kampen A. Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients. Int Orthop. 2007;31:709-714. (Pubitemid 47573359)
    • (2007) International Orthopaedics , vol.31 , Issue.5 , pp. 709-714
    • Janssen, K.W.1    Biert, J.2    Van Kampen, A.3
  • 11
    • 46149089655 scopus 로고    scopus 로고
    • Intramedullary tibial nailing in distal third tibial fractures: Distal locking screws and fracture nonunion
    • Mohammed A, Saravanan R, Zammit J, et al. Intramedullary tibial nailing in distal third tibial fractures: distal locking screws and fracture nonunion. Int Orthop. 2008;32:547.
    • (2008) Int. Orthop. , vol.32 , pp. 547
    • Mohammed, A.1    Saravanan, R.2    Zammit, J.3
  • 12
    • 9244230661 scopus 로고    scopus 로고
    • Comparison of intramedullary nailing of distal third tibial shaft fractures: Before and after traumatologists
    • Obremskey WT, Medina M. Comparison of intramedullary nailing of distal third tibial shaft fractures: before and after traumatologists. Orthopedics. 2004;27:1180-1184. (Pubitemid 39549592)
    • (2004) Orthopedics , vol.27 , Issue.11 , pp. 1180-1184
    • Obremskey, W.T.1    Medina, M.2
  • 13
    • 43049088134 scopus 로고    scopus 로고
    • Radiographic and clinical comparisons of distal tibia shaft fractures (4 to 11 cm proximal to the plafond): Plating versus intramedullary nailing
    • DOI 10.1097/BOT.0b013e31816ed974, PII 0000513120080500000004
    • Vallier HA, Le TT, Bedi A. Radiographic and clinical comparisons of distal tibia shaft fractures (4 to 11 cm proximal to the plafond): plating versus intramedullary nailing. J Orthop Trauma. 2008;22:307-311. (Pubitemid 351630243)
    • (2008) Journal of Orthopaedic Trauma , vol.22 , Issue.5 , pp. 307-311
    • Vallier, H.A.1    Le, T.T.2    Bedi, A.3
  • 14
    • 67651031258 scopus 로고    scopus 로고
    • Intramedullary nailing of proximal and distal one-third tibial shaft fractures with intraoperative two-pin external fixation
    • Wysocki RW, Kapotas JS, Virkus WW. Intramedullary nailing of proximal and distal one-third tibial shaft fractures with intraoperative two-pin external fixation. J Trauma. 2009;66:1135-1139.
    • (2009) J. Trauma. , vol.66 , pp. 1135-1139
    • Wysocki, R.W.1    Kapotas, J.S.2    Virkus, W.W.3
  • 16
    • 17044435463 scopus 로고    scopus 로고
    • Interlocking nails for displaced metaphyseal fractures of the distal tibia
    • Fan CY, Chiang CC, Chuang TY, et al. Interlocking nails for displaced metaphyseal fractures of the distal tibia. Injury. 2005;36:669-674.
    • (2005) Injury , vol.36 , pp. 669-674
    • Fan, C.Y.1    Chiang, C.C.2    Chuang, T.Y.3
  • 17
    • 0035064143 scopus 로고    scopus 로고
    • Mechanical boundary conditions of fracture healing: Borderline indications in the treatment of unreamed tibial nailing
    • DOI 10.1016/S0021-9290(00)00237-2, PII S0021929000002372
    • Duda GN, Mandruzzato F, Heller M, et al. Mechanical boundary conditions of fracture healing: borderline indications in the treatment of unreamed tibial nailing. J Biomech. 2001;34:639-650. (Pubitemid 32328252)
    • (2001) Journal of Biomechanics , vol.34 , Issue.5 , pp. 639-650
    • Duda, G.N.1    Mandruzzato, F.2    Heller, M.3    Goldhahn, J.4    Moser, R.5    Hehli, M.6    Claes, L.7    Haas, N.P.8
  • 18
    • 66149087778 scopus 로고    scopus 로고
    • Intramedullary bone formation after intramedullary nailing
    • Papadakis SA, Segkos D, Katsiva V, et al. Intramedullary bone formation after intramedullary nailing. J Orthop Trauma. 2009;23:288-293.
    • (2009) J. Orthop. Trauma. , vol.23 , pp. 288-293
    • Papadakis, S.A.1    Segkos, D.2    Katsiva, V.3
  • 20
    • 0028307944 scopus 로고
    • Osteosynthesis of 245 tibial shaft fractures: Early and late complications
    • Bilat C, Leutenegger A, Ruedi T. Osteosynthesis of 245 tibial shaft fractures: early and late complications. Injury. 1994;25:349-358.
    • (1994) Injury , vol.25 , pp. 349-358
    • Bilat, C.1    Leutenegger, A.2    Ruedi, T.3
  • 22
    • 0035127754 scopus 로고    scopus 로고
    • Initial rotational stability of distal tibial fractures nailed without proximal locking: The importance of fracture type and degree of cortical contact
    • DOI 10.1016/S0020-1383(00)00157-1, PII S0020138300001571
    • Drosos G, Karnezis IA, Bishay M, et al. Initial rotational stability of distal tibial fractures nailed without proximal locking: the importance of fracture type and degree of cortical contact. Injury. 2001;32:137-143. (Pubitemid 32149672)
    • (2001) Injury , vol.32 , Issue.2 , pp. 137-143
    • Drosos, G.1    Karnezis, I.A.2    Bishay, M.3    Miles, A.W.4
  • 23
    • 0036739510 scopus 로고    scopus 로고
    • Malrotation after locked intramedullary tibial nailing: Three case reports and review of the literature
    • Kahn KM, Beals RK. Malrotation after locked intramedullary tibial nailing: three case reports and review of the literature. J Trauma. 2002;53:549-552.
    • (2002) J. Trauma. , vol.53 , pp. 549-552
    • Kahn, K.M.1    Beals, R.K.2
  • 24
    • 66449103000 scopus 로고    scopus 로고
    • Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: A biomechanical study
    • Horn J, Linke B, Hoentzsch D, et al. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study. Injury. 2009;40:767-771.
    • (2009) Injury , vol.40 , pp. 767-771
    • Horn, J.1    Linke, B.2    Hoentzsch, D.3
  • 25
    • 0025930609 scopus 로고
    • Complications of reamed intramedullary nailing of the tibia
    • Koval KJ, Clapper MF, Brumback RJ, et al. Complications of reamed intramedullary nailing of the tibia. J Orthop Trauma. 1991;5:184-189.
    • (1991) J. Orthop. Trauma. , vol.5 , pp. 184-189
    • Koval, K.J.1    Clapper, M.F.2    Brumback, R.J.3
  • 26
    • 0032615782 scopus 로고    scopus 로고
    • Should distal interlocking of tibial nails be performed from a medial or a lateral direction? Anatomical and biomechanical considerations
    • Roberts CS, King D, Wang M, et al. Should distal interlocking of tibial nails be performed from a medial or a lateral direction? Anatomical and biomechanical considerations. J Orthop Trauma. 1999;13:27-32. (Pubitemid 128701899)
    • (1998) Journal of Orthopaedic Trauma , vol.13 , Issue.1 , pp. 27-32
    • Roberts, C.S.1
  • 27
    • 0029445725 scopus 로고
    • Complications of nailing in closed tibial fractures
    • Williams J, Gibbons M, Trundle H, et al. Complications of nailing in closed tibial fractures. J Orthop Trauma. 1995;9:476-481.
    • (1995) J. Orthop. Trauma. , vol.9 , pp. 476-481
    • Williams, J.1    Gibbons, M.2    Trundle, H.3
  • 28
    • 0024423377 scopus 로고
    • Serious vascular complication of locked tibial nailing
    • DOI 10.1016/0020-1383(89)90181-2
    • Williamson DM, Kershaw CJ. Serious vascular complication of locked tibial nailing. Injury. 1989;20:310-312. (Pubitemid 19233494)
    • (1989) Injury , vol.20 , Issue.5 , pp. 310-312
    • Williamson, D.M.1    Kershaw, C.J.2
  • 29
    • 0344393615 scopus 로고    scopus 로고
    • Neurovascular and tendinous damage with placement of anteroposterior distal locking bolts in the tibia
    • DOI 10.1097/00005131-200311000-00003
    • Bono CM, Sirkin M, Sabatino CT, et al. Neurovascular and tendinous damage with placement of anteroposterior distal locking bolts in the tibia. J Orthop Trauma. 2003;17:677-682. (Pubitemid 37455800)
    • (2003) Journal of Orthopaedic Trauma , vol.17 , Issue.10 , pp. 677-682
    • Bono, C.M.1    Sirkin, M.2    Sabatino, C.T.3    Reilly, M.C.4    Tarkin, I.5    Behrens, F.F.6
  • 30
    • 57349178352 scopus 로고    scopus 로고
    • Quantification of cancellous bone-compaction due to DHS blade insertion and influence upon cut-out resistance
    • Windolf M, Muths R, Braunstein V, et al. Quantification of cancellous bone-compaction due to DHS blade insertion and influence upon cut-out resistance. Clin Biomech (Bristol, Avon). 2009;24:53-58.
    • (2009) Clin. Biomech. (Bristol, Avon) , vol.24 , pp. 53-58
    • Windolf, M.1    Muths, R.2    Braunstein, V.3
  • 33
    • 65249134232 scopus 로고    scopus 로고
    • Fatigue strength of common tibial intramedullary nail distal locking screws
    • Griffin LV, Harris RM, Zubak JJ. Fatigue strength of common tibial intramedullary nail distal locking screws. J Orthop Surg Res. 2009;4:11.
    • (2009) J. Orthop. Surg. Res. , vol.4 , pp. 11
    • Griffin, L.V.1    Harris, R.M.2    Zubak, J.J.3
  • 34
    • 0032060887 scopus 로고    scopus 로고
    • Optimal Location of a Single Distal Interlocking Screw in Intramedullary Nailing of Distal Third Femoral Shaft Fractures
    • George CJ, Lindsey RW, Noble PC, et al. Optimal location of a single distal interlocking screw in intramedullary nailing of distal third femoral shaft fractures. J Orthop Trauma. 1998;12:267-272. (Pubitemid 128454119)
    • (1998) Journal of Orthopaedic Trauma , vol.12 , Issue.4 , pp. 267-272
    • George, C.J.1    Lindsey, R.W.2    Noble, P.C.3    Alexander, J.W.4    Kamaric, E.5
  • 35
    • 0026020749 scopus 로고
    • Role of interfragmentary strain in fracture healing: Ovine model of a healing osteotomy
    • Cheal EJ, Mansmann KA, DiGioia AM 3rd, et al. Role of interfragmentary strain in fracture healing: ovine model of a healing osteotomy. J Orthop Res. 1991;9:131-142.
    • (1991) J. Orthop. Res. , vol.9 , pp. 131-142
    • Cheal, E.J.1    Mansmann, K.A.2    DiGioia III, A.M.3
  • 36
    • 10644249303 scopus 로고    scopus 로고
    • Functional load of plates in fracture fixation in vivo and its correlate in bone healing
    • Stoffel K, Klaue K, Perren SM. Functional load of plates in fracture fixation in vivo and its correlate in bone healing. Injury. 2000;31(suppl 2):S-B37-50.
    • (2000) Injury , vol.31 , Issue.2 SUPPL.
    • Stoffel, K.1    Klaue, K.2    Perren, S.M.3
  • 37
    • 24644484024 scopus 로고    scopus 로고
    • Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing: Study of a displaced osteotomy model in sheep tibiae
    • DOI 10.2106/JBJS.D.02268
    • Kaspar K, Schell H, Seebeck P, et al. Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing. Study of a displaced osteotomy model in sheep tibiae. J Bone Joint Surg Am. 2005;87:2028-2037. (Pubitemid 41279135)
    • (2005) Journal of Bone and Joint Surgery - Series A , vol.87 , Issue.9 , pp. 2028-2037
    • Kaspar, K.1    Schell, H.2    Seebeck, P.3    Thompson, M.S.4    Schutz, M.5    Haas, N.P.6    Duda, G.N.7
  • 40
    • 0031989581 scopus 로고    scopus 로고
    • Vascular Compromise and Amputation after Intramedullary Nailing of a Tibia Fracture
    • Roberts C, Ruktanonchai D, King D, et al. Vascular compromise and amputation after intramedullary nailing of a tibia fracture. J Orthop Trauma. 1998;12:136-138. (Pubitemid 128452802)
    • (1998) Journal of Orthopaedic Trauma , vol.12 , Issue.2 , pp. 136-138
    • Roberts, C.1    Ruktanonchai, D.2    King, D.3    Seligson, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.