메뉴 건너뛰기




Volumn 16, Issue 2, 2011, Pages

Direct measurements of blood glucose concentration in the presence of saccharide interferences using slope and bias orthogonal signal correction and Fourier transform near-infrared spectroscopy

Author keywords

Blood glucose measurements; Fourier transform infrared spectroscopy; Maximum interference effect; Orthogonal signal correction; Saccharide interferents

Indexed keywords

BLOOD GLUCOSE MEASUREMENTS; FOURIER TRANSFORM INFRARED; INTERFERENTS; MAXIMUM INTERFERENCE EFFECT; ORTHOGONAL SIGNAL CORRECTION;

EID: 79957812065     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3540408     Document Type: Article
Times cited : (17)

References (20)
  • 2
    • 6044275963 scopus 로고    scopus 로고
    • Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium
    • O. S. Khalil, "Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium," Diabetes. Technol. Ther. 6, 660 (2004).
    • (2004) Diabetes. Technol. Ther. , vol.6 , pp. 660
    • Khalil, O.S.1
  • 3
    • 0034967077 scopus 로고    scopus 로고
    • Preliminary investigation of near-infrared spectroscopic measurements of urea, creatinine, glucose, protein, and ketone in urine
    • K. J. Pezzaniti, T.-W. Jeng, L. McDowell, and G. Oosta, "Preliminary investigation of near-infrared spectroscopic measurements of urea, creatinine, glucose, protein, and ketone in urine," Clin. Biochem. 34, 239 (2001).
    • (2001) Clin. Biochem. , vol.34 , pp. 239
    • Pezzaniti, K.J.1    Jeng, T.-W.2    McDowell, L.3    Oosta, G.4
  • 4
    • 24644444644 scopus 로고    scopus 로고
    • Noninvasive glucose sensing
    • M. A. Arnold and G. W. Small, "Noninvasive glucose sensing," Anal. Chem. 77, 5429 (2005).
    • (2005) Anal. Chem. , vol.77 , pp. 5429
    • Arnold, M.A.1    Small, G.W.2
  • 6
    • 30044440884 scopus 로고    scopus 로고
    • In vivo near-infrared spectroscopy of rat skin tissue with varying blood glucose levels
    • J. T. Olesberg, L. Liu, V. V. Zee, and M. A. Arnold, "In vivo near-infrared spectroscopy of rat skin tissue with varying blood glucose levels," Anal. Chem. 78, 215 (2006).
    • (2006) Anal. Chem. , vol.78 , pp. 215
    • Olesberg, J.T.1    Liu, L.2    Zee, V.V.3    Arnold, M.A.4
  • 7
    • 33744771301 scopus 로고    scopus 로고
    • New methodology to obtain a calibration model for noninvasive near-infrared blood glucose monitoring
    • K. Maruo, T. Oota, M. Tsurugi, T. Nakagawa, H. Arimoto, M. Tamura, Y. Ozaki, and Y. Yamada, "New methodology to obtain a calibration model for noninvasive near-infrared blood glucose monitoring," Appl. Spectr. 60, 441 (2006).
    • (2006) Appl. Spectr. , vol.60 , pp. 441
    • Maruo, K.1    Oota, T.2    Tsurugi, M.3    Nakagawa, T.4    Arimoto, H.5    Tamura, M.6    Ozaki, Y.7    Yamada, Y.8
  • 8
    • 34248174355 scopus 로고    scopus 로고
    • Recent progress in analytical instrumentation for glycemic control in diabetic and critically ill patients
    • V. R. Kondepati and H. M. Heise, "Recent progress in analytical instrumentation for glycemic control in diabetic and critically ill patients," Anal. Bioanal. Chem. 388, 545 (2007).
    • (2007) Anal. Bioanal. Chem. , vol.388 , pp. 545
    • Kondepati, V.R.1    Heise, H.M.2
  • 9
    • 0034005547 scopus 로고    scopus 로고
    • Effects of drugs on glucose measurements with handheld glucose meters and a portable glucose analyzer
    • Z. Tang, X. Du, R. F. Louie, and G. J. Kost, "Effects of drugs on glucose measurements with handheld glucose meters and a portable glucose analyzer," Am. J. Clin. Pathol. 113, 75 (2000).
    • (2000) Am. J. Clin. Pathol. , vol.113 , pp. 75
    • Tang, Z.1    Du, X.2    Louie, R.F.3    Kost, G.J.4
  • 13
    • 80455172919 scopus 로고
    • 2nd ed, Chapman & Hall, London
    • A. P. Throne, Spectrophysics, 2nd ed., Chapman & Hall, London (1988).
    • (1988) Spectrophysics
    • Throne, A.P.1
  • 14
    • 11144325691 scopus 로고
    • Partial least-squares regression; a tutorial
    • P. Geladi and B. R. Kowalski, "Partial Least-Squares regression; a tutorial," Anal. Chim. Acta 185, 1 (1986).
    • (1986) Anal. Chim. Acta , vol.185 , pp. 1
    • Geladi, P.1    Kowalski, B.R.2
  • 16
    • 0035946444 scopus 로고    scopus 로고
    • Orthogonal signal correction in near infrared calibration
    • M. Blanco, J. Coello, I. Montoliu, and M. A. Rometo, "Orthogonal signal correction in near infrared calibration," Anal. Chim. Acta. 434, 125 (2001).
    • (2001) Anal. Chim. Acta. , vol.434 , pp. 125
    • Blanco, M.1    Coello, J.2    Montoliu, I.3    Rometo, M.A.4
  • 17
    • 84861975201 scopus 로고    scopus 로고
    • http://www.eigenvector.com/MATLAB/PC-M-files/osccalc.m
  • 18
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • W. L. Clarke, D. Cox, L. A. Gonder-Frederick, W. Carter, and S. L. Pohl, "Evaluating clinical accuracy of systems for self-monitoring of blood glucose," Diabetes Care 10, 622 (1987).
    • (1987) Diabetes Care , vol.10 , pp. 622
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3    Carter, W.4    Pohl, S.L.5
  • 19


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.