메뉴 건너뛰기




Volumn 66, Issue 3-4, 2011, Pages 255-260

Simultaneous electrothermal vaporization and nebulizer sample introduction system for inductively coupled plasma mass spectrometry

Author keywords

Electrothermal vaporization; ETV ICP MS; Inductively coupled plasma mass spectrometry; Nebulizer

Indexed keywords

ANALYTES; ANALYTICAL APPLICATIONS; DETECTION LIMITS; DRY PLASMAS; ELECTROTHERMAL VAPORIZATION; ETV-ICP-MS; GAS FLOWS; GLASS NEBULIZER; IN-LINE; LIMITS OF DETECTION; MATRIX; NEBULIZER; OPERATING CONDITION; PLASMA CONDITIONS; POLYATOMIC INTERFERENCES; POLYATOMICS; POWER SETTINGS; SAMPLE INTRODUCTION; TIME OF FLIGHT MASS SPECTROMETRY; TIME-RESOLVED; TRANSPORT LINE;

EID: 79957804514     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2011.02.004     Document Type: Article
Times cited : (6)

References (25)
  • 1
    • 0022709674 scopus 로고
    • Background spectral features in inductively coupled plasma/mass spectrometry
    • S.H. Tan, and G. Horlick Background spectral features in inductively coupled plasma/mass spectrometry Appl. Spectrosc. 40 1986 445 460 (Pubitemid 16553877)
    • (1986) Applied Spectroscopy , vol.40 , Issue.4 , pp. 445-460
    • Tan, S.H.1    Horlick, G.2
  • 2
    • 0001908186 scopus 로고
    • Alternatives to all-argon plasmas in inductively coupled plasma mass spectrometry (ICP-MS): An overview
    • S.F. Durrant Alternatives to all-argon plasmas in inductively coupled plasma mass spectrometry (ICP-MS): an overview Fresenius J. Anal. Chem. 347 1993 389 392
    • (1993) Fresenius J. Anal. Chem. , vol.347 , pp. 389-392
    • Durrant, S.F.1
  • 3
    • 0002300901 scopus 로고
    • Mixed-gas, molecular-gas, and helium inductively coupled plasmas for analytical atomic spectrometry: A critical review
    • A. Montaser, and R.L. Van Hoven Mixed-gas, molecular-gas, and helium inductively coupled plasmas for analytical atomic spectrometry: a critical review CRC Crit. Rev. Anal. Chem. 18 1987 45 103
    • (1987) CRC Crit. Rev. Anal. Chem. , vol.18 , pp. 45-103
    • Montaser, A.1    Van Hoven, R.L.2
  • 4
    • 44949284872 scopus 로고
    • Evaluation of a modified commercial graphite furnace for reduction of isobaric interferences in argon inductively coupled plasma mass spectrometry
    • J.M. Carey, E.H. Evans, J.A. Caruso, and W.L. Shen Evaluation of a modified commercial graphite furnace for reduction of isobaric interferences in argon inductively coupled plasma mass spectrometry Spectrochim. Acta Part B 46 1991 1711 1721
    • (1991) Spectrochim. Acta Part B , vol.46 , pp. 1711-1721
    • Carey, J.M.1    Evans, E.H.2    Caruso, J.A.3    Shen, W.L.4
  • 5
    • 0033118284 scopus 로고    scopus 로고
    • Preliminary investigation of electrothermal vaporization sample introduction for inductively coupled plasma time-of-flight mass spectrometry
    • DOI 10.1021/ac9811625
    • P.P. Mahoney, S.J. Ray, G. Li, and G.M. Hieftje Preliminary investigation of electrothermal vaporization sample introduction for inductively coupled plasma time-of-flight mass spectrometry Anal. Chem. 71 1999 1378 1383 (Pubitemid 29177297)
    • (1999) Analytical Chemistry , vol.71 , Issue.7 , pp. 1378-1383
    • Mahoney, P.P.1    Ray, S.J.2    Li, G.3    Hieftje, G.M.4
  • 6
    • 0000002642 scopus 로고    scopus 로고
    • 3 modifier
    • J.P. Byrne, and G. Chapple Direct determination of trace metals in seawater by electrothermal vaporization ICP-MS with Pd-HNO3 modifier At. Spectrosc. 19 1998 116 120 (Pubitemid 128474880)
    • (1998) Atomic Spectroscopy , vol.19 , Issue.4 , pp. 116-120
    • Byrne, J.P.1    Chapple, G.2
  • 7
    • 0030217043 scopus 로고    scopus 로고
    • Direct determination of trace metals in sea-water using electrothermal vaporization inductively coupled plasma mass spectrometry
    • G. Chapple, and J.P. Byrne Direct determination of trace metals in sea-water using electrothermal vaporization inductively coupled plasma mass spectrometry J. Anal. At. Spectrom. 11 1996 549 553 (Pubitemid 126627901)
    • (1996) Journal of Analytical Atomic Spectrometry , vol.11 , Issue.8 , pp. 549-553
    • Chapple, G.1    Byrne, J.P.2
  • 9
    • 23744509469 scopus 로고    scopus 로고
    • Optimization of ETV-ICP(TOF)MS and transient signal profiles for reducing isobaric interferences
    • DOI 10.1039/b505482f
    • G. Ertas, and J.A. Holcombe Optimization of ETV-ICP(TOF)MS and transient signal profiles for reducing isobaric interferences J. Anal. At. Spectrom. 20 2005 687 695 (Pubitemid 41121401)
    • (2005) Journal of Analytical Atomic Spectrometry , vol.20 , Issue.8 , pp. 687-695
    • Ertas, G.1    Holcombe, J.A.2
  • 10
    • 38549097011 scopus 로고    scopus 로고
    • Use of electrothermal vaporization for volatility-based separation of Rb-Sr isobars for determination of isotopic ratios by ICP-MS
    • DOI 10.1039/b709089g
    • A. Rowland, T.B. Housh, and J.A. Holcombe Use of electrothermal vaporization for volatility-based separation of Rb-Sr isobars for determination of isotopic ratios by ICP-MS J. Anal. At. Spectrom. 23 2008 167 172 (Pubitemid 351162635)
    • (2008) Journal of Analytical Atomic Spectrometry , vol.23 , Issue.2 , pp. 167-172
    • Rowland, A.1    Housh, T.B.2    Holcombe, J.A.3
  • 11
    • 54949083109 scopus 로고    scopus 로고
    • Electrothermal vaporization for sample introduction in atomic absorption, atomic emission and plasma mass spectrometry - A critical review with focus on solid sampling and slurry analysis
    • M. Resano, F. Vanhaecke, and M.T.C. de Loos-Vollebregt Electrothermal vaporization for sample introduction in atomic absorption, atomic emission and plasma mass spectrometry-a critical review with focus on solid sampling and slurry analysis J. Anal. At. Spectrom. 23 2008 1450 1475
    • (2008) J. Anal. At. Spectrom. , vol.23 , pp. 1450-1475
    • Resano, M.1    Vanhaecke, F.2    De Loos-Vollebregt, M.T.C.3
  • 12
    • 67650586870 scopus 로고    scopus 로고
    • Electrothermal vaporization-inductively coupled plasma-mass spectrometry: A versatile tool for tackling challenging samples. A critical review
    • M. Aramendia, M. Resano, and F. Vanhaecke Electrothermal vaporization-inductively coupled plasma-mass spectrometry: a versatile tool for tackling challenging samples. A critical review Anal. Chim. Acta 648 2009 23 44
    • (2009) Anal. Chim. Acta , vol.648 , pp. 23-44
    • Aramendia, M.1    Resano, M.2    Vanhaecke, F.3
  • 13
    • 33947264176 scopus 로고    scopus 로고
    • Recent progress in electrothermal vaporization-inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry
    • DOI 10.1080/05704920601184317, PII 771404952, Contributions from China
    • B. Hu, S. Li, G. Xiang, M. He, and Z. Jiang Recent progress in electrothermal vaporization-inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry Appl. Spectrosc. Rev. 42 2007 203 234 (Pubitemid 46431422)
    • (2007) Applied Spectroscopy Reviews , vol.42 , Issue.2 , pp. 203-234
    • Hu, B.1    Li, S.2    Xiang, G.3    He, M.4    Jiang, Z.5
  • 14
    • 0033084111 scopus 로고    scopus 로고
    • Thermophoretic collection and analysis of submicrometer Ag particles emitted from a graphite tube-type electrothermal vaporizer
    • D. Langer, and J.A. Holcombe Thermophoretic collection and analysis of submicrometer Ag particles emitted from a graphite tube-type electrothermal vaporizer Anal. Chem. 71 1999 582 588
    • (1999) Anal. Chem. , vol.71 , pp. 582-588
    • Langer, D.1    Holcombe, J.A.2
  • 15
    • 0141888102 scopus 로고    scopus 로고
    • Elemental fractionation in the formation of particulates, as observed by simultaneous isotopes measurement using laser ablation ICP-oa-TOFMS
    • B. Kozlov, A. Saint, and A. Skroce Elemental fractionation in the formation of particulates, as observed by simultaneous isotopes measurement using laser ablation ICP-oa-TOFMS J. Anal. At. Spectrom. 18 2003 1069 1075
    • (2003) J. Anal. At. Spectrom. , vol.18 , pp. 1069-1075
    • Kozlov, B.1    Saint, A.2    Skroce, A.3
  • 16
    • 33745835104 scopus 로고    scopus 로고
    • 2 mixed-gas plasma by electrothermal vaporization inductively coupled plasma orthogonal time-of-flight mass spectrometry
    • DOI 10.1016/j.sab.2006.02.008, PII S0584854706000462
    • W.J. Balsanek, G. Ertas, and J.A. Holcombe The use of concomitant elements to evaluate an Ar-N2 mixed-gas plasma by electrothermal vaporization inductively coupled plasma orthogonal time-of-flight mass spectrometry Spectrochim. Acta Part B 61 2006 732 742 (Pubitemid 44038144)
    • (2006) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.61 , Issue.6 , pp. 732-742
    • Balsanek, W.J.1    Ertas, G.2    Holcombe, J.A.3
  • 17
    • 0034300590 scopus 로고    scopus 로고
    • Characterization of pressure pulse and carrier gas flow changes resulting from pulsed heating in ETV-ICP-MS
    • J. Venable, T. Williamson, and J.A. Holcombe Characterization of pressure pulse and carrier gas flow changes resulting from pulsed heating in ETV-ICP-MS J. Anal. At. Spectrom. 15 2000 1329 1334
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 1329-1334
    • Venable, J.1    Williamson, T.2    Holcombe, J.A.3
  • 18
    • 84969201214 scopus 로고
    • Signal enhancement of elements due to the presence of carbon-containing compounds in inductively coupled plasma mass spectrometry
    • P. Allain, L. Jaunault, Y. Mauras, J.M. Mermet, and T. Delaporte Signal enhancement of elements due to the presence of carbon-containing compounds in inductively coupled plasma mass spectrometry Anal. Chem. 63 1991 1497 1498
    • (1991) Anal. Chem. , vol.63 , pp. 1497-1498
    • Allain, P.1    Jaunault, L.2    Mauras, Y.3    Mermet, J.M.4    Delaporte, T.5
  • 19
    • 0034225017 scopus 로고    scopus 로고
    • Signal enhancements produced from externally generated 'carrier' particles in electrothermal vaporization-inductively coupled plasma mass spectrometry
    • J.D. Venable, and J.A. Holcombe Signal enhancements produced from externally generated 'carrier' particles in electrothermal vaporization- inductively coupled plasma mass spectrometry Spectrochim. Acta Part B 55 2000 753 766
    • (2000) Spectrochim. Acta Part B , vol.55 , pp. 753-766
    • Venable, J.D.1    Holcombe, J.A.2
  • 20
    • 0001202031 scopus 로고
    • Influence of water on conditions in the inductively coupled argon plasma
    • S.E. Long, and R.F. Browner Influence of water on conditions in the inductively coupled argon plasma Spectrochim. Acta Part B 43 1988 1461 1471
    • (1988) Spectrochim. Acta Part B , vol.43 , pp. 1461-1471
    • Long, S.E.1    Browner, R.F.2
  • 21
    • 0039776374 scopus 로고
    • Use of the Ar2+ signal as a diagnostic tool in solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry
    • F. Vanhaecke, G. Galbacs, S. Boonen, L. Moens, and R. Dams Use of the Ar2+ signal as a diagnostic tool in solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry J. Anal. At. Spectrom. 10 1995 1047 1052
    • (1995) J. Anal. At. Spectrom. , vol.10 , pp. 1047-1052
    • Vanhaecke, F.1    Galbacs, G.2    Boonen, S.3    Moens, L.4    Dams, R.5
  • 22
    • 0027592190 scopus 로고
    • Effect of added hydrogen in electrothermal vaporization inductively coupled plasma atomic emission spectrometry
    • DOI 10.1016/0584-8547(93)80088-C
    • J.P. Matousek, and J.M. Mermet The effect of added hydrogen in electrothermal vaporization inductively coupled plasma atomic emission spectrometry Spectrochim. Acta Part B 488 1993 835 850 (Pubitemid 23682538)
    • (1993) Spectrochimica acta, Part B: Atomic spectroscopy , vol.48 , Issue.6-7 , pp. 835-850
    • Matousek, J.P.1    Mermet, J.M.2
  • 23
    • 33744812707 scopus 로고    scopus 로고
    • On-line additions of aqueous standards for calibration of laser ablation inductively coupled plasma mass spectrometry: Theory and comparison of wet and dry plasma conditions
    • DOI 10.1039/b600916f
    • C. O'Connor, B.L. Sharp, and P. Evans On-line additions of aqueous standards for calibration of laser ablation inductively coupled plasma mass spectrometry: theory and comparison of wet and dry plasma conditions J. Anal. At. Spectrom. 21 2006 556 565 (Pubitemid 43839344)
    • (2006) Journal of Analytical Atomic Spectrometry , vol.21 , Issue.6 , pp. 556-565
    • O'Connor, C.1    Sharp, B.L.2    Evans, P.3
  • 24
    • 77956992005 scopus 로고    scopus 로고
    • Laser ablation single-collector inductively coupled plasma mass spectrometry for lead isotopic analysis to investigate evolution of the Bilbilis mint
    • M. Resano, M.P. Marzo, R. Alloza, C. Saenz, F. Vanhaecke, L. Yang, S. Willie, and R.E. Sturgeon Laser ablation single-collector inductively coupled plasma mass spectrometry for lead isotopic analysis to investigate evolution of the Bilbilis mint Anal. Chim. Acta 677 2010 55 63
    • (2010) Anal. Chim. Acta , vol.677 , pp. 55-63
    • Resano, M.1    Marzo, M.P.2    Alloza, R.3    Saenz, C.4    Vanhaecke, F.5    Yang, L.6    Willie, S.7    Sturgeon, R.E.8
  • 25
    • 77649201275 scopus 로고    scopus 로고
    • Isotope ratio determination by laser ablation-single collector- inductively coupled plasma-mass spectrometry: General capabilities and possibilities for improvement
    • M. Aramendia, M. Resano, and F. Vanhaecke Isotope ratio determination by laser ablation-single collector-inductively coupled plasma-mass spectrometry: general capabilities and possibilities for improvement J. Anal. At. Spectrom. 25 2010 390 404
    • (2010) J. Anal. At. Spectrom. , vol.25 , pp. 390-404
    • Aramendia, M.1    Resano, M.2    Vanhaecke, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.