메뉴 건너뛰기




Volumn 1, Issue 2, 2007, Pages 201-204

How to design a biosensor

Author keywords

Biosensor; Design; Diabetes; Glucose

Indexed keywords


EID: 79957796589     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229680700100210     Document Type: Article
Times cited : (9)

References (12)
  • 1
    • 0028304845 scopus 로고
    • BCL-2 expression or antioxidants prevent hyperglycemia-induced formation of intracellular advanced glycation endproducts in bovine endothelial cells
    • Jul.
    • Giardino I, Edelstein D, Brownlee M. BCL-2 expression or antioxidants prevent hyperglycemia-induced formation of intracellular advanced glycation endproducts in bovine endothelial cells. J Clin Invest. 1994 Jul; 94(1):110-7.
    • (1994) J Clin Invest. , vol.94 , Issue.1 , pp. 110-117
    • Giardino, I.1    Edelstein, D.2    Brownlee, M.3
  • 2
    • 0025671780 scopus 로고
    • Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly (o-phenylenediamine) film
    • Dec. 15
    • Malitesta C, Palmisano F, Torsi L, Zambonin PG. Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly (o-phenylenediamine) film. Anal Chem. 1990 Dec. 15;62(24):2735-40.
    • (1990) Anal Chem. , vol.62 , Issue.24 , pp. 2735-2740
    • Malitesta, C.1    Palmisano, F.2    Torsi, L.3    Zambonin, P.G.4
  • 3
    • 0028418786 scopus 로고
    • Elimination of the acetaminophen interference in an implantable glucose sensor
    • Apr. l
    • Zhang, Y., Hu Y, Wilson GS, Moatti-Sirat D, Poitout V, Reach G. Elimination of the acetaminophen interference in an implantable glucose sensor. Anal Chem. 1994 Apr. l; 66(7):1183-8.
    • (1994) Anal Chem. , vol.66 , Issue.7 , pp. 1183-1188
    • Zhang, Y.1    Hu, Y.2    Wilson, G.S.3    Moatti-Sirat, D.4    Poitout, V.5    Reach, G.6
  • 4
    • 0013483195 scopus 로고    scopus 로고
    • Direct non-enzymic amperometric glucose sensor based on a novel glucose selective membrane
    • Benmakroha Y, Christie I, Vadgama P. Direct non-enzymic amperometric glucose sensor based on a novel glucose selective membrane. Anal. Commun. 1996;33:23-5.
    • (1996) Anal. Commun. , vol.33 , pp. 23-25
    • Benmakroha, Y.1    Christie, I.2    Vadgama, P.3
  • 8
    • 0027236355 scopus 로고
    • In vitro and in vivo evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor
    • Zhang Y, Wilson GS. In vitro and in vivo evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor. Anal Chim Acta. 1993;281:513-20.
    • (1993) Anal Chim Acta. , vol.281 , pp. 513-520
    • Zhang, Y.1    Wilson, G.S.2
  • 9
    • 0036660705 scopus 로고    scopus 로고
    • Continuous amperometric monitoring of subcutaneous oxygen in rabbit by telemetry
    • Jul-Aug
    • Ward W K, Wood MD, Slobodzian EP. Continuous amperometric monitoring of subcutaneous oxygen in rabbit by telemetry. J Med Eng Technol. 2002 Jul-Aug; 26(4):158-67.
    • (2002) J Med Eng Technol. , vol.26 , Issue.4 , pp. 158-167
    • Ward, W.K.1    Wood, M.D.2    Slobodzian, E.P.3
  • 10
    • 0025689061 scopus 로고
    • Application of chronic intravascular blood glucose sensor in dogs
    • Dec.
    • Armour JC, Lucisano JY, McKean BD, Gough DA. Application of chronic intravascular blood glucose sensor in dogs. Diabetes. 1990 Dec; 39(12):1519-26.
    • (1990) Diabetes. , vol.39 , Issue.12 , pp. 1519-1526
    • Armour, J.C.1    Lucisano, J.Y.2    McKean, B.D.3    Gough, D.A.4
  • 11
    • 0032313338 scopus 로고    scopus 로고
    • Electrochemical oxidation of hydrogen peroxide at platinum electrodes. Part 1. An adsorptioncontrolled mechanism
    • Hall SB, Khudaish EA, Hart AL. Electrochemical oxidation of hydrogen peroxide at platinum electrodes. Part 1. An adsorptioncontrolled mechanism. Electrochim Acta. 1998;43(5):579-88.
    • (1998) Electrochim Acta. , vol.43 , Issue.5 , pp. 579-588
    • Hall, S.B.1    Khudaish, E.A.2    Hart, A.L.3
  • 12
    • 0028394265 scopus 로고
    • Prevention of rapid degradation of subcutaneously implanted ag/agcl reference electrodes using polymer coatings
    • Mar. 1
    • Moussy F, Harrison DJ. Prevention of rapid degradation of subcutaneously implanted ag/agcl reference electrodes using polymer coatings. Anal Chem. 1994 Mar. 1;66(5):674-9.
    • (1994) Anal Chem. , vol.66 , Issue.5 , pp. 674-679
    • Moussy, F.1    Harrison, D.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.