메뉴 건너뛰기




Volumn 36, Issue 11, 2011, Pages 3023-3030

Theoretical model to estimate the thermal performance of an evaporative wind tower placed in an open space

Author keywords

Evaporative systems; Lineal regression; TRNSYS model; Wind tower

Indexed keywords

ADIABATIC COOLING; AVERAGE TEMPERATURE; CONSERVATION OF MASS; CONVECTION AND CONDUCTION; COOLING POWER; ENERGY ESTIMATION; ENVIRONMENTAL CONDITIONS; EVAPORATIVE SYSTEMS; EXPERIMENTAL DATA; INJECTED WATER; LINEAL REGRESSION; MASS EXCHANGE; NUMERICAL SIMULATION; OPEN SPACE; RELATIVE HUMIDITIES; SIMULATION TOOL; THEORETICAL MODELS; THERMAL BEHAVIOURS; THERMAL PERFORMANCE; TRNSYS MODEL; WATER OPERATIONS; WET BULB DEPRESSION; WIND TOWER; WIND TOWERS;

EID: 79957795853     PISSN: 09601481     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.renene.2011.03.035     Document Type: Article
Times cited : (17)

References (19)
  • 2
    • 0030100756 scopus 로고    scopus 로고
    • Refining the use of evaporation in an experimental down-draft cool tower
    • Pearlmutter D., Etzion Y., Erell E., Meir I.A., Di H. Refining the use of evaporation in an experimental down-draft cool tower. Energy and Buildings 1996, 23(3):191-197.
    • (1996) Energy and Buildings , vol.23 , Issue.3 , pp. 191-197
    • Pearlmutter, D.1    Etzion, Y.2    Erell, E.3    Meir, I.A.4    Di, H.5
  • 4
    • 79960896651 scopus 로고    scopus 로고
    • Monitorization of one evaporative wind tower in an open space.
    • 3rd International conference passive and low energy cooling for the built environment. Rhodes island, Greece
    • Soutullo S, Sánchez N, Olmedo R, Heras M.R, Monitorization of one evaporative wind tower in an open space. 3rd International conference passive and low energy cooling for the built environment. Rhodes island, Greece (2010).
    • (2010)
    • Soutullo, S.1    Sánchez, N.2    Olmedo, R.3    Heras, M.R.4
  • 6
    • 0021942758 scopus 로고
    • An improved design of wind towers for natural ventilation and passive cooling
    • Bahadori M.N. An improved design of wind towers for natural ventilation and passive cooling. Solar Energy 1985, 35(2):119-129.
    • (1985) Solar Energy , vol.35 , Issue.2 , pp. 119-129
    • Bahadori, M.N.1
  • 7
    • 17144459856 scopus 로고    scopus 로고
    • Climatic solar roof: an ecological alternative to heat dissipation in buildings
    • Sánchez M.M., Lucas M., Martínez P., Sánchez A., Viedma A. Climatic solar roof: an ecological alternative to heat dissipation in buildings. Solar Energy 2002, 73(6):419-432.
    • (2002) Solar Energy , vol.73 , Issue.6 , pp. 419-432
    • Sánchez, M.M.1    Lucas, M.2    Martínez, P.3    Sánchez, A.4    Viedma, A.5
  • 8
    • 51649127699 scopus 로고    scopus 로고
    • Numerical simulation of cooling performance of wind tower (Baud-Geer) in hot and arid region
    • Kalantar V. Numerical simulation of cooling performance of wind tower (Baud-Geer) in hot and arid region. Renewable Energy 2008, 34:246-254.
    • (2008) Renewable Energy , vol.34 , pp. 246-254
    • Kalantar, V.1
  • 10
    • 79957810304 scopus 로고    scopus 로고
    • American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta (
    • ASHRAE, psychrometrics, ASHRAE handbook of fundamentals 1999, American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta
    • (1999) ASHRAE, psychrometrics, ASHRAE handbook of fundamentals
  • 11
    • 9144246956 scopus 로고    scopus 로고
    • Cooling tower performance: a critical evaluation of the Merkel assumptions
    • Kloppers J.C., Kröger D.G. Cooling tower performance: a critical evaluation of the Merkel assumptions. R&D Journal 2004, 20(1):24-29.
    • (2004) R&D Journal , vol.20 , Issue.1 , pp. 24-29
    • Kloppers, J.C.1    Kröger, D.G.2
  • 13
    • 13644269403 scopus 로고
    • Merkel's cooling diagram as a performance correlation for air water evaporative cooling system
    • Nottage H.B. Merkel's cooling diagram as a performance correlation for air water evaporative cooling system. ASHVE Trans. 1941, 47.
    • (1941) ASHVE Trans. , vol.47
    • Nottage, H.B.1
  • 14
    • 10444285030 scopus 로고    scopus 로고
    • A critical investigation into the heat and mass transfer analysis of counterflow wet-cooling towers
    • Kloppers J.C., Kröger D.G. A critical investigation into the heat and mass transfer analysis of counterflow wet-cooling towers. International Journal of Heat and Mass Transfer 2005, 48:765-777.
    • (2005) International Journal of Heat and Mass Transfer , vol.48 , pp. 765-777
    • Kloppers, J.C.1    Kröger, D.G.2
  • 15
    • 79957803458 scopus 로고    scopus 로고
    • American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta
    • Ashrae, heat transfer, ASHRAE handbook of fundamentals 1999, American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta.
    • (1999) Ashrae, heat transfer, ASHRAE handbook of fundamentals
  • 16
    • 79957830092 scopus 로고    scopus 로고
    • American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta
    • Ashrae, mass transfer, ASHRAE handbook of fundamentals 1999, American Society of Heating, Refrigerating and Air Conditioning Engineers, Atlanta.
    • (1999) Ashrae, mass transfer, ASHRAE handbook of fundamentals
  • 17
    • 41949092698 scopus 로고    scopus 로고
    • A multi-stage down-draft evaporative cool tower for semi-enclosed spaces: aerodynamic performance
    • Erell E., Pearlmutter D., Etzion Y. A multi-stage down-draft evaporative cool tower for semi-enclosed spaces: aerodynamic performance. Solar Energy 2008, 82:420-429.
    • (2008) Solar Energy , vol.82 , pp. 420-429
    • Erell, E.1    Pearlmutter, D.2    Etzion, Y.3
  • 19
    • 41949086355 scopus 로고    scopus 로고
    • A multi-stage down-draft evaporative cool tower for semi-enclosed spaces: experiments with a water spraying system
    • Pearlmutter D., Erell E., Etzion Y. A multi-stage down-draft evaporative cool tower for semi-enclosed spaces: experiments with a water spraying system. Solar Energy 2008, 82:430-440.
    • (2008) Solar Energy , vol.82 , pp. 430-440
    • Pearlmutter, D.1    Erell, E.2    Etzion, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.