메뉴 건너뛰기




Volumn 156, Issue 1, 2011, Pages 388-394

A label-free amperometric immunosensor based on horseradish peroxidase functionalized carbon nanotubes and bilayer gold nanoparticles

Author keywords

1 Fetoprotein; Bilayer gold nanoparticles; Horseradish peroxidase labeled carbon nanotubes; Label free immunosensor

Indexed keywords

AMPEROMETRIC IMMUNOSENSORS; BI-LAYER; BIOCONJUGATES; CLINICAL DIAGNOSIS; CURRENT RESPONSE; DETECTION LIMITS; ELECTROCHEMICAL REDUCTIONS; ENHANCED SENSITIVITY; FETOPROTEIN; FUNCTIONALIZED CARBON NANOTUBES; GLASS CARBON ELECTRODES; GOLD COLLOIDAL NANOPARTICLES; GOLD NANOPARTICLE; GOLD NANOPARTICLES; HORSE-RADISH PEROXIDASE; HUMAN SERUM; LABEL FREE; LABEL-FREE IMMUNOSENSOR; LINEAR RANGE; OPTIMIZED CONDITIONS; REPRODUCIBILITIES;

EID: 79957793222     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2011.04.062     Document Type: Article
Times cited : (29)

References (25)
  • 1
    • 36549082481 scopus 로고    scopus 로고
    • Nanomaterial labels in electrochemical immunosensors and immunoassays
    • DOI 10.1016/j.talanta.2007.10.014, PII S0039914007006789, Micro- and Nanotechnology in Electrochemical Detection Science - dedicated to Professor Joseph Wang on the occasion of his 60th birthday MNED 2007 SI
    • G. Liu, and Y. Lin Nanomaterial labels in electrochemical immunosensors and immunoassays Talanta 74 2007 308 317 (Pubitemid 350192537)
    • (2007) Talanta , vol.74 , Issue.3 , pp. 308-317
    • Liu, G.1    Lin, Y.2
  • 2
    • 68549092590 scopus 로고    scopus 로고
    • Designing nanomaterial enhanced electrochemical immunosensors for cancer biomarker proteins
    • J.F. Rusling, G. Sotzing, and F. Papadimitrakopoulosa Designing nanomaterial enhanced electrochemical immunosensors for cancer biomarker proteins Bioelectrochemistry 76 2009 189 194
    • (2009) Bioelectrochemistry , vol.76 , pp. 189-194
    • Rusling, J.F.1    Sotzing, G.2    Papadimitrakopoulosa, F.3
  • 3
    • 0035878196 scopus 로고    scopus 로고
    • Renewable amperometric immunosensor for schistosoma japonium antibody assay
    • G.D. Liu, Z.Y. Wu, S.P. Wang, G.L. Shen, and R.Q. Yu Renewable amperometric immunosensor for schistosoma japonium antibody assay Anal. Chem. 73 2001 3219 3226
    • (2001) Anal. Chem. , vol.73 , pp. 3219-3226
    • Liu, G.D.1    Wu, Z.Y.2    Wang, S.P.3    Shen, G.L.4    Yu, R.Q.5
  • 4
    • 36448995446 scopus 로고    scopus 로고
    • Amperometric immunosensor for the detection of anti-West Nile virus IgG
    • DOI 10.1021/ac0707129
    • R.E. Ionescu, S. Cosnier, S. Herrmann, and R.S. Marks Amperometric immunosensor for the detection of anti-west nile virus IgG Anal. Chem. 79 2007 8662 8668 (Pubitemid 350171377)
    • (2007) Analytical Chemistry , vol.79 , Issue.22 , pp. 8662-8668
    • Ionescu, R.E.1    Cosnier, S.2    Herrmann, S.3    Marks, R.S.4
  • 6
    • 35448966139 scopus 로고    scopus 로고
    • Disposable electrochemical immunosensor diagnosis device based on nanoparticle probe and immunochromatographic strip
    • DOI 10.1021/ac070691i
    • G. Liu, Y.Y. Lin, J. Wang, H. Wu, C.M. Wai, and Y.H. Lin Disposable electrochemical immunosensor diagnosis device based on nanoparticle probe and immunochromatographic strip Anal. Chem. 79 2007 7644 7653 (Pubitemid 47622391)
    • (2007) Analytical Chemistry , vol.79 , Issue.20 , pp. 7644-7653
    • Liu, G.1    Lin, Y.-Y.2    Wang, J.3    Wu, H.4    Wai, C.M.5    Lin, Y.6
  • 7
    • 0030587065 scopus 로고    scopus 로고
    • Application of redox enzymes for probing the antigen-antibody association at monolayer interfaces: Development of amperometric immunosensor electrodes
    • R. Blonder, E. Katz, Y. Cohen, N. Itzhak, A. Riklin, and I. Willner Application of redox enzymes for probing the antigen-antibody association at monolayer interfaces: development of amperometric immunosensor electrodes Anal. Chem. 68 1996 3151 3157
    • (1996) Anal. Chem. , vol.68 , pp. 3151-3157
    • Blonder, R.1    Katz, E.2    Cohen, Y.3    Itzhak, N.4    Riklin, A.5    Willner, I.6
  • 8
    • 7444270533 scopus 로고    scopus 로고
    • Regeneration of ethyl parathion antibodies for repeated use in immunosensor: A study on dissociation of antigens from antibodies
    • DOI 10.1016/j.bios.2004.03.027, PII S0956566304001629, Microarrays for Biodefence and Environmental Applications
    • V.B. Kandimalla, N.S. Neeta, N.G. Karanth, M.S. Thakur, K.R. Roshini, B.E.A. Rani, A. Pasha, and N.G.K. Karanth Regeneration of ethyl parathion antibodies for repeated use in immunosensor: a study on dissociation of antigens from antibodies Biosens. Bioelectron. 20 2004 902 905 (Pubitemid 39441272)
    • (2004) Biosensors and Bioelectronics , vol.20 , Issue.4 , pp. 902-905
    • Kandimalla, V.B.1    Neeta, N.S.2    Karanth, N.G.3    Thakur, M.S.4    Roshini, K.R.5    Rani, B.E.A.6    Pasha, A.7    Karanth, N.G.K.8
  • 9
    • 33847356841 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopy for study of amyloid β-peptide interactions with (-) nicotine ditartrate and (-) cotinine
    • DOI 10.1016/j.bios.2006.08.025, PII S095656630600399X, Selected Papers from the Ninth World Congress On Biosensors
    • I. Szymanska, H. Radecka, J. Radecki, and R. Kaliszan Electrochemical impedance spectroscopy for study of amyloid [beta]-peptide interactions with (-) nicotine ditartrate and (-) cotinine Biosens. Bioelectron. 22 2007 1955 1960 (Pubitemid 46349631)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.9-10 , pp. 1955-1960
    • Szymanska, I.1    Radecka, H.2    Radecki, J.3    Kaliszan, R.4
  • 10
    • 35348912690 scopus 로고    scopus 로고
    • Bienzymatic glucose biosensor based on co-immobilization of peroxidase and glucose oxidase on a carbon nanotubes electrode
    • DOI 10.1016/j.bios.2007.07.002, PII S0956566307002801
    • L. Zhu, R. Yang, J. Zhai, and C.Y. Tian Bienzymatic glucose biosensor based on co-immobilization of peroxidase and glucose oxidase on a carbon nanotubes electrode Biosens. Bioelectron. 23 2007 528 535 (Pubitemid 47575895)
    • (2007) Biosensors and Bioelectronics , vol.23 , Issue.4 , pp. 528-535
    • Zhu, L.1    Yang, R.2    Zhai, J.3    Tian, C.4
  • 11
    • 0342819025 scopus 로고
    • Helical microtubules of graphitic carbon
    • S. Iijima Helical microtubules of graphitic carbon Nature 354 1991 56 58 (Pubitemid 21896780)
    • (1991) Nature , vol.354 , Issue.6348 , pp. 56-58
    • Iijima, S.1
  • 14
    • 0041779850 scopus 로고    scopus 로고
    • Science and technology of the twenty-first century: Synthesis, properties, and applications of carbon nanotubes
    • M. Terrones Science and technology of the twenty-first century: synthesis, properties, and applications of carbon nanotubes Ann. Rev. Mater. Res. 33 2003 419 501
    • (2003) Ann. Rev. Mater. Res. , vol.33 , pp. 419-501
    • Terrones, M.1
  • 15
    • 2442683134 scopus 로고    scopus 로고
    • Basal plane pyrolytic graphite modified electrodes: Comparison of carbon nanotubes and graphite powder as electrocatalysts
    • DOI 10.1021/ac040017q
    • R.R. Moore, C.E. Banks, and R.G. Compton Basal plane pyrolytic graphite modified electrodes: comparison of carbon nanotubes and graphite powder as electrocatalysts Anal. Chem. 76 2004 2677 2682 (Pubitemid 38657689)
    • (2004) Analytical Chemistry , vol.76 , Issue.10 , pp. 2677-2682
    • Moore, R.R.1    Banks, C.E.2    Compton, R.G.3
  • 16
    • 63849130246 scopus 로고    scopus 로고
    • Electrochemical sensors based on carbon nanotubes
    • A.J. Saleh Ahammad, J.-J. Lee, and Md. Aminur Rahman Electrochemical sensors based on carbon nanotubes Sensors 9 2009 2289 2319
    • (2009) Sensors , vol.9 , pp. 2289-2319
    • Saleh Ahammad, A.J.1    Lee, J.-J.2    Rahman, Md.A.3
  • 17
    • 33748423070 scopus 로고    scopus 로고
    • A reagentless tyrosinase biosensor based on 1,6-hexanedithiol and nano-Au self-assembled monolayers
    • Z. Liu, j. Liu, G. Shen, and R. Yu A reagentless tyrosinase biosensor based on 1,6-hexanedithiol and nano-Au self-assembled monolayers Electroanalysis 18 2006 1572 1577
    • (2006) Electroanalysis , vol.18 , pp. 1572-1577
    • Liu, Z.1    Liu, J.2    Shen, G.3    Yu, R.4
  • 18
    • 4344653974 scopus 로고    scopus 로고
    • Ultrasensitive potentiometric immunosensor based on SA and OCA techniques for immobilization of HBsAb with colloidal Au and polyvinyl butyral as matrixes
    • R. Yuan, D.P. Tang, Y.Q. Chai, X. Zhong, Y. Liu, and J.Y. Dai Ultrasensitive potentiometric immunosensor based on SA and OCA techniques for immobilization of HBsAb with colloidal Au and polyvinyl butyral as matrixes Langmuir 20 2004 7240 7245
    • (2004) Langmuir , vol.20 , pp. 7240-7245
    • Yuan, R.1    Tang, D.P.2    Chai, Y.Q.3    Zhong, X.4    Liu, Y.5    Dai, J.Y.6
  • 19
    • 0003051583 scopus 로고
    • Preparation of gold dispersions of varying particle size: Controlled nucleation for the regulation of the particle size in monodisperse gold suspensions
    • G. Frens Preparation of gold dispersions of varying particle size: controlled nucleation for the regulation of the particle size in monodisperse gold suspensions Nat. Phys. Sci. 241 1973 20 22
    • (1973) Nat. Phys. Sci. , vol.241 , pp. 20-22
    • Frens, G.1
  • 23
    • 3242883894 scopus 로고    scopus 로고
    • Fabrication of layer-by-layer deposited multilayer films containing DNA and gold nanoparticle for norepinephrine biosensor
    • L.P. Lu, S.Q. Wang, and X.Q. Lin Fabrication of layer-by-layer deposited multilayer films containing DNA and gold nanoparticle for norepinephrine biosensor Anal. Chim. Acta 519 2004 161 166
    • (2004) Anal. Chim. Acta , vol.519 , pp. 161-166
    • Lu, L.P.1    Wang, S.Q.2    Lin, X.Q.3
  • 24
    • 0011277298 scopus 로고    scopus 로고
    • Enzyme-linked immunoassay of a-1-fetoprotein in serum by differential pulse voltammetry
    • H.X. Ju, G.F. Yan, F. Chen, and H.Y. Chen Enzyme-linked immunoassay of a-1-fetoprotein in serum by differential pulse voltammetry Electroanalysis 11 1999 124 128
    • (1999) Electroanalysis , vol.11 , pp. 124-128
    • Ju, H.X.1    Yan, G.F.2    Chen, F.3    Chen, H.Y.4
  • 25
    • 74549195702 scopus 로고    scopus 로고
    • Multilayer structured amperometric immunosensor based on gold nanoparticles and Prussian blue nanoparticles/nanocomposite functionalized interface
    • Z.J. Song, R. Yuan, Y.Q. Chai, B. Yin, P. Fu, and J.F. Wang Multilayer structured amperometric immunosensor based on gold nanoparticles and Prussian blue nanoparticles/nanocomposite functionalized interface Electrochim. Acta 55 2010 1778 1784
    • (2010) Electrochim. Acta , vol.55 , pp. 1778-1784
    • Song, Z.J.1    Yuan, R.2    Chai, Y.Q.3    Yin, B.4    Fu, P.5    Wang, J.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.