메뉴 건너뛰기




Volumn 31, Issue 4, 2011, Pages 458-464

Experience with the fassier-duval telescopic rod: First 24 consecutive cases with a minimum of 1-year follow-up

Author keywords

Fassier Duval; osteogenesis imperfecta; telescopic rod

Indexed keywords

ARTICLE; BONE RADIOGRAPHY; BONE TRANSPLANTATION; CHILD; CLINICAL ARTICLE; CONGENITAL BONE DISEASE; EPIDERMAL NAEVUS SYNDROME; FASSIER DUVAL TELESCOPIC ROD; FEMALE; FEMUR; FOLLOW UP; FRACTURE HEALING; HUMAN; HYPOPHOSPHATEMIC RICKETS; JOINT INTRUSION; LEG LENGTHENING; LOSS OF FIXATION; MALE; MEDICAL RECORD REVIEW; NERVE INJURY; NEUROFIBROMATOSIS; NEUROLYSIS; ORTHOPEDIC EQUIPMENT; ORTHOPEDIC SURGERY; OSTEOGENESIS IMPERFECTA; PERONEAL NEUROPRAXIA; POSTOPERATIVE COMPLICATION; PRESCHOOL CHILD; PRIORITY JOURNAL; PROSTHESIS FAILURE; PSEUDARTHROSIS; REOPERATION; RETROSPECTIVE STUDY; ROD MIGRATION; SCHOOL CHILD; TIBIA; TIBIA CONGENITAL PSEUDARTHROSIS;

EID: 79957762174     PISSN: 02716798     EISSN: 15392570     Source Type: Journal    
DOI: 10.1097/BPO.0b013e31821bfb50     Document Type: Article
Times cited : (94)

References (15)
  • 2
    • 0031976130 scopus 로고    scopus 로고
    • Management of lower-extremity deformities in osteogenesis imperfecta with extensible intramedullary rod technique: A 20-year experience
    • DOI 10.1097/00004694-199801000-00017
    • Luhmann SJ, Sheridan JJ, Capelli AM, et al. Management of lower-extremity deformities in osteogenesis imperfecta with extensible intramedullary rod technique: a 20-year experience. J Pediatr Orthop. 1998;18:88-94. (Pubitemid 28051576)
    • (1998) Journal of Pediatric Orthopaedics , vol.18 , Issue.1 , pp. 88-94
    • Luhmann, S.J.1    Sheridan, J.J.2    Capelli, A.M.3    Schoenecker, P.L.4
  • 3
    • 0034051503 scopus 로고    scopus 로고
    • Intramedullary rodding in osteogenesis imperfecta
    • DOI 10.1097/00004694-200003000-00027
    • Mulpuri K, Joseph B. Intramedullary rodding in osteogenesis imperfecta. J Pediatr Orthop. 2000;20:267-273. (Pubitemid 30140664)
    • (2000) Journal of Pediatric Orthopaedics , vol.20 , Issue.2 , pp. 267-273
    • Mulpuri, K.1    Joseph, B.2
  • 4
    • 0025972237 scopus 로고
    • Functional results of operation in osteogenesis imperfecta: Elongating and nonelongating rods
    • Porat S, Heller E, Seidman DS, et al. Functional results of operation in osteogenesis imperfecta: elongating and nonelongating rods. J Pediatr Orthop. 1991;11:200-203.
    • (1991) J Pediatr Orthop. , vol.11 , pp. 200-203
    • Porat, S.1    Heller, E.2    Seidman, D.S.3
  • 5
    • 0001290507 scopus 로고
    • Fragmentation, realignment, and intra-medullary rod fixation of deformities of the long bones in children: A ten year appraisal
    • Sofield HA, Millar EA. Fragmentation, realignment, and intra-medullary rod fixation of deformities of the long bones in children: a ten year appraisal. J Bone Joint Surg [Am]. 1959;1371-1391.
    • (1959) J Bone Joint Surg [Am]. , pp. 1371-1391
    • Sofield, H.A.1    Millar, E.A.2
  • 6
    • 0000284340 scopus 로고
    • Studies of longitudinal bone growth resulting in an extensible nail
    • Bailey RW, Dubow HI. Studies of longitudinal bone growth resulting in an extensible nail. Surg Forum. 1963;14:455-458.
    • (1963) Surg Forum. , vol.14 , pp. 455-458
    • Bailey, R.W.1    Dubow, H.I.2
  • 8
    • 0023741624 scopus 로고
    • Complications of intramedullary rods in osteogenesis imperfecta: Bailey-Dubow rods versus nonelongating rods
    • Gamble JG, Strudwick WJ, Rinsky LA, et al. Complications of intramedullary rods in osteogenesis imperfecta: Bailey-Dubow rods versus nonelongating rods. J Pediatr Orthop. 1988;8:645-649.
    • (1988) J Pediatr Orthop. , vol.8 , pp. 645-649
    • Gamble, J.G.1    Strudwick, W.J.2    Rinsky, L.A.3
  • 9
  • 11
    • 0031765649 scopus 로고    scopus 로고
    • Surgical stabilisation of the lower limb in osteogenesis imperfecta using the Sheffield telescopic intramedullary rod system
    • Wilkinson JM, Scott BW, Clarke AM, et al. Surgical stabilisation of the lower limb in osteogenesis imperfecta using the Sheffield Telescopic Intramedullary Rod System. J Bone Joint Surg Br. 1998; 80:999-1004. (Pubitemid 28528402)
    • (1998) Journal of Bone and Joint Surgery - Series B , vol.80 , Issue.6 , pp. 999-1004
    • Wilkinson, J.M.1    Scott, B.W.2    Clarke, A.M.3    Bell, M.J.4
  • 12
    • 79957764469 scopus 로고    scopus 로고
    • Fassier-Duval telescopic im system
    • Pega Medical QC. Fassier-Duval Telescopic IM System. Surgical Technique. 2009;1:1-19.
    • (2009) Surgical Technique. , vol.1 , pp. 1-19
    • Pega Medical, Q.C.1
  • 13
    • 34248159894 scopus 로고    scopus 로고
    • Interlocking telescopic rod for patients with osteogenesis imperfecta
    • Cho TJ, Choi IH, Chung CY, et al. Interlocking telescopic rod for patients with osteogenesis imperfecta. J Bone Joint Surg Am. 2007; 89:1028-1035.
    • (2007) J Bone Joint Surg Am. , vol.89 , pp. 1028-1035
    • Cho, T.J.1    Choi, I.H.2    Chung, C.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.