메뉴 건너뛰기




Volumn 8, Issue 6, 2011, Pages 821-825

Cryoballoon temperature predicts acute pulmonary vein isolation

Author keywords

Arrhythmia; Atrial fibrillation; Balloon; Catheter ablation; Cryothermal

Indexed keywords

ADULT; AGED; ARTICLE; CRYOABLATION; CRYOBALLOON ABLATION; CRYOBALLOON TEMPERATURE; FEMALE; HEART ATRIUM FIBRILLATION; HUMAN; MAJOR CLINICAL STUDY; MALE; PREDICTIVE VALUE; PRIORITY JOURNAL; PULMONARY VEIN; PULMONARY VEIN ISOLATION; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; TEMPERATURE MEASUREMENT;

EID: 79957699817     PISSN: 15475271     EISSN: 15563871     Source Type: Journal    
DOI: 10.1016/j.hrthm.2011.01.044     Document Type: Article
Times cited : (72)

References (16)
  • 1
    • 64949092842 scopus 로고    scopus 로고
    • The "single big cryoballoon" technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: A prospective observational single centre study
    • Chun KR, Schmidt B, Metzner A, et al. The "single big cryoballoon" technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. Eur Heart J 2009;30:699-709.
    • (2009) Eur Heart J , vol.30 , pp. 699-709
    • Chun, K.R.1    Schmidt, B.2    Metzner, A.3
  • 3
    • 55249120449 scopus 로고    scopus 로고
    • One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillation
    • Van Belle Y, Janse P, Theuns D, Szili-Torok T, Jordaens L. One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillation. Europace 2008;10:1271-1276.
    • (2008) Europace , vol.10 , pp. 1271-1276
    • Van Belle, Y.1    Janse, P.2    Theuns, D.3    Szili-Torok, T.4    Jordaens, L.5
  • 4
    • 44649124294 scopus 로고    scopus 로고
    • Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation
    • Klein G, Oswald H, Gardiwal A, et al. Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillation. Heart Rhythm 2008;5:802-806.
    • (2008) Heart Rhythm , vol.5 , pp. 802-806
    • Klein, G.1    Oswald, H.2    Gardiwal, A.3
  • 5
    • 70350602048 scopus 로고    scopus 로고
    • Cryoballoon pulmonary vein isolation guided by transesophageal echocardiography: Novel aspects on an emerging ablation technique
    • Siklody CH, Minners J, Allgeier M, et al. Cryoballoon pulmonary vein isolation guided by transesophageal echocardiography: novel aspects on an emerging ablation technique. J Cardiovasc Electrophysiol 2009;20:1197-1202.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 1197-1202
    • Siklody, C.H.1    Minners, J.2    Allgeier, M.3
  • 6
    • 78249274626 scopus 로고    scopus 로고
    • Intracardiac echocardiography improves procedural efficiency during cryoballoon ablation for atrial fibrillation: A pilot study
    • Schmidt M, Daccarett M, Marschang H, et al. Intracardiac echocardiography improves procedural efficiency during cryoballoon ablation for atrial fibrillation: a pilot study. J Cardiovasc Electrophysiol 2010;21:1202-1207.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 1202-1207
    • Schmidt, M.1    Daccarett, M.2    Marschang, H.3
  • 7
    • 78650097548 scopus 로고    scopus 로고
    • Cryoballoon pulmonary vein isolation supported by intracardiac echocardiography: Integration of a nonfluoroscopic imaging technique in atrial fibrillation ablation
    • Nölker G, Heintze J, Gutleben KJ, et al. Cryoballoon pulmonary vein isolation supported by intracardiac echocardiography: integration of a nonfluoroscopic imaging technique in atrial fibrillation ablation. J Cardiovasc Electrophysiol 2010;21:1325-1330.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 1325-1330
    • Nölker, G.1    Heintze, J.2    Gutleben, K.J.3
  • 8
    • 75749096313 scopus 로고    scopus 로고
    • Pressure-guided cryoballoon isolation of the pulmonary veins for the treatment of paroxysmal atrial fibrillation
    • Siklody CH, Minners J, Allgeier M, et al. Pressure-guided cryoballoon isolation of the pulmonary veins for the treatment of paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 2010;21:120-125.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 120-125
    • Siklody, C.H.1    Minners, J.2    Allgeier, M.3
  • 9
    • 77954062048 scopus 로고    scopus 로고
    • The permanency of pulmonary vein isolation using a balloon cryoablation catheter
    • Ahmed H, Neuzil P, Skoda J, et al. The permanency of pulmonary vein isolation using a balloon cryoablation catheter. J Cardiovasc Electrophysiol 2010;21:731-737.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 731-737
    • Ahmed, H.1    Neuzil, P.2    Skoda, J.3
  • 10
    • 84855591707 scopus 로고    scopus 로고
    • Cryoballoon applications after acute pulmonary vein isolation - The Alster Extra study. PO6-49
    • Chun KRJ, Köster I, Metzner A, et al. Cryoballoon applications after acute pulmonary vein isolation - the Alster Extra study. PO6-49. Heart Rhythm 2010; 7:S382-S445.
    • (2010) Heart Rhythm , vol.7
    • Chun, K.R.J.1    Köster, I.2    Metzner, A.3
  • 11
    • 77955240556 scopus 로고    scopus 로고
    • Esophageal endoscopy results after pulmonary vein isolation using the single big cryoballoon technique
    • Fürnkranz A, Chun KR, Metzner A, et al. Esophageal endoscopy results after pulmonary vein isolation using the single big cryoballoon technique. J Cardiovasc Electrophysiol 2010;21:869-974.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 869-974
    • Fürnkranz, A.1    Chun, K.R.2    Metzner, A.3
  • 12
    • 71049120282 scopus 로고    scopus 로고
    • Cryoballoon pulmonary vein isolation with real-time recordings from the pulmonary veins
    • Chun KR, Fürnkranz A, Metzner A, et al. Cryoballoon pulmonary vein isolation with real-time recordings from the pulmonary veins. J Cardiovasc Electrophysiol 2009;20:1203-1210.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 1203-1210
    • Chun, K.R.1    Fürnkranz, A.2    Metzner, A.3
  • 14
    • 74549189389 scopus 로고    scopus 로고
    • Characterization of conduction recovery after pulmonary vein isolation using the "single big cryoballoon" technique
    • Fürnkranz A, Chun KR, Nuyens D, et al. Characterization of conduction recovery after pulmonary vein isolation using the "single big cryoballoon" technique. Heart Rhythm 2010;7:184-190.
    • (2010) Heart Rhythm , vol.7 , pp. 184-190
    • Fürnkranz, A.1    Chun, K.R.2    Nuyens, D.3
  • 15
    • 34548803112 scopus 로고    scopus 로고
    • Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: Feasibility, complications, and short-term outcome
    • DOI 10.1093/eurheartj/ehm227
    • Van Belle Y, Janse P, Rivero-Ayerza MJ, et al. Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. Eur Heart J 2007;28:2231-2237. (Pubitemid 47428935)
    • (2007) European Heart Journal , vol.28 , Issue.18 , pp. 2231-2237
    • Van Belle, Y.1    Janse, P.2    Rivero-Ayerza, M.J.3    Thornton, A.S.4    Jessurun, E.R.5    Theuns, D.6    Jordaens, L.7
  • 16
    • 65249190133 scopus 로고    scopus 로고
    • Early recovery of pulmonary vein conduction after cryoballoon ablation for paroxysmal atrial fibrillation: A prospective study
    • Chierchia GB, de Asmundis C, Muller-Burri SA, et al. Early recovery of pulmonary vein conduction after cryoballoon ablation for paroxysmal atrial fibrillation: a prospective study. Europace 2009;11:445-449.
    • (2009) Europace , vol.11 , pp. 445-449
    • Chierchia, G.B.1    De Asmundis, C.2    Muller-Burri, S.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.