메뉴 건너뛰기




Volumn 212, Issue 6, 2011, Pages

Hepatobiliary surgery guided by a novel fluorescent imaging technique for visualizing hepatic arteries, bile ducts, and liver cancers on color images

Author keywords

[No Author keywords available]

Indexed keywords

INDOCYANINE GREEN;

EID: 79957582730     PISSN: 10727515     EISSN: 18791190     Source Type: Journal    
DOI: 10.1016/j.jamcollsurg.2011.03.006     Document Type: Article
Times cited : (63)

References (25)
  • 1
    • 0036065325 scopus 로고    scopus 로고
    • A new and simplified method for coronary and graft imaging during CABG
    • Rubens FD, Ruel M, Fremes SE. A new and simplified method for coronary and graft imaging during CABG. Heart Surg Forum 2002;5:141-144. (Pubitemid 34790208)
    • (2002) Heart Surgery Forum , vol.5 , Issue.2 , pp. 141-144
    • Rubens, F.D.1    Ruel, M.2    Fremes, S.E.3
  • 2
    • 0037338127 scopus 로고    scopus 로고
    • Preliminary experience with a novel intraoperative fluorescence imaging technique to evaluate the patency of bypass grafts in total arterial revascularization
    • DOI 10.1016/S0003-4975(02)04669-6, PII S0003497502046696
    • Taggart DP, Choudhary B, Anastasiadis K, et al. Preliminary experience with a novel intraoperative fluorescence imaging technique to evaluate the patency of bypass grafts in total arterial revascularization. Ann Thorac Surg 2003;75:870-873. (Pubitemid 36298360)
    • (2003) Annals of Thoracic Surgery , vol.75 , Issue.3 , pp. 870-873
    • Taggart, D.P.1    Choudhary, B.2    Anastasiadis, K.3    Abu-Omar, Y.4    Balacumaraswami, L.5    Pigott, D.W.6
  • 3
    • 10744229782 scopus 로고    scopus 로고
    • Novadaq SPY: Intraoperative Quality Assessment in Off-Pump Coronary Artery Bypass Grafting
    • DOI 10.1378/chest.125.2.418
    • Reuthebuch O, Haussler A, Genoni M, et al. intraoperative quality assessment in off-pump coronary artery bypass grafting. Chest 2004;125:418-424. (Pubitemid 38223617)
    • (2004) Chest , vol.125 , Issue.2 , pp. 418-424
    • Reuthebuch, O.1    Haussler, A.2    Genoni, M.3    Tavakoli, R.4    Odavic, D.5    Kadner, A.6    Turina, M.7
  • 4
    • 23044436834 scopus 로고    scopus 로고
    • A comparison of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency
    • DOI 10.1016/j.jtcvs.2004.11.033, PII S0022522304016940
    • Balacumaraswami L, Abu-Omar Y, Choudhary B, et al. A comparison of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency. J Thorac Cardiovasc Surg 2005;130:315-320. (Pubitemid 41074159)
    • (2005) Journal of Thoracic and Cardiovascular Surgery , vol.130 , Issue.2 , pp. 315-320
    • Balacumaraswami, L.1    Abu-Omar, Y.2    Choudhary, B.3    Pigott, D.4    Taggart, D.P.5
  • 5
    • 34547702288 scopus 로고    scopus 로고
    • Intraoperative lymphography using indocyanine green dye for near-infrared fluorescence labeling in lymphedema
    • DOI 10.1097/01.sap.0000253341.70866.54, PII 0000063720070800000013
    • Ogata F, Narushima M, Mihara M, et al: Intraoperative lymphography using indocyanine green dye for near-infrared fluorescence labeling in lymphedema. Ann Plast Surg 2007;59:180-184. (Pubitemid 47220423)
    • (2007) Annals of Plastic Surgery , vol.59 , Issue.2 , pp. 180-184
    • Ogata, F.1    Narushima, M.2    Mihara, M.3    Azuma, R.4    Morimoto, Y.5    Koshima, I.6
  • 6
    • 27744510449 scopus 로고    scopus 로고
    • Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer
    • KitaiT, InomotoT,Miwa M, et al. Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer. Breast Cancer 2005;12:211-215.
    • (2005) Breast Cancer , vol.12 , pp. 211-215
    • Kitai, T.1    Inomoto, T.2    Miwa, M.3
  • 7
    • 77953363852 scopus 로고    scopus 로고
    • Evaluation of sentinel node biopsy by combined fluorescent and dye method and lymph flow for breast cancer
    • Hojo T, Nagao T, Kikuyama M, et al. Evaluation of sentinel node biopsy by combined fluorescent and dye method and lymph flow for breast cancer. Breast 2010;19:210-213.
    • (2010) Breast , vol.19 , pp. 210-213
    • Hojo, T.1    Nagao, T.2    Kikuyama, M.3
  • 8
    • 44349104168 scopus 로고    scopus 로고
    • Sentinel node mapping guided by indocyanine green fluorescence imaging: A new method for sentinel node navigation surgery in gastrointestinal cancer
    • DOI 10.1159/000121905
    • Kusano M, Tajima Y, Yamazaki K, et al. Sentinel node mapping guided by indocyanine green fluorescence imaging: a new method for sentinel node navigation surgery in gastrointestinal cancer. Dig Surg 2008;25:103-108. (Pubitemid 351748763)
    • (2008) Digestive Surgery , vol.25 , Issue.2 , pp. 103-108
    • Kusano, M.1    Tajima, Y.2    Yamazaki, K.3    Kato, M.4    Watanabe, M.5    Miwa, M.6
  • 10
    • 66649121434 scopus 로고    scopus 로고
    • Real-time identification of liver cancers by using indocyanine green fluorescent imaging
    • Ishizawa T, Fukushima N, Shibahara J, et al. Real-time identification of liver cancers by using indocyanine green fluorescent imaging. Cancer 2009;115:2491-2504.
    • (2009) Cancer , vol.115 , pp. 2491-2504
    • Ishizawa, T.1    Fukushima, N.2    Shibahara, J.3
  • 11
    • 65349184066 scopus 로고    scopus 로고
    • Fluorescent cholangiography using indocyanine green for laparoscopic cholecystectomy: An initial experience
    • Ishizawa T, Bandai Y, Kokudo N. Fluorescent cholangiography using indocyanine green for laparoscopic cholecystectomy: an initial experience. Arch Surg 2009;144:381-382.
    • (2009) Arch Surg , vol.144 , pp. 381-382
    • Ishizawa, T.1    Bandai, Y.2    Kokudo, N.3
  • 12
    • 77956418611 scopus 로고    scopus 로고
    • Fluorescent cholangiography illuminating the biliary tree during laparoscopic cholecystectomy
    • Ishizawa T, Bandai Y, Ijichi M, et al. Fluorescent cholangiography illuminating the biliary tree during laparoscopic cholecystectomy. Br J Surg 2010;97:1369-1377.
    • (2010) Br J Surg , vol.97 , pp. 1369-1377
    • Ishizawa, T.1    Bandai, Y.2    Ijichi, M.3
  • 13
    • 57749198243 scopus 로고    scopus 로고
    • Intraoperative fluorescent cholangiography using indocyanine green: A biliary road map for safe surgery
    • Ishizawa T, Tamura S, Masuda K, et al. Intraoperative fluorescent cholangiography using indocyanine green: a biliary road map for safe surgery. J Am Coll Surg 2008;208:e1-e4.
    • (2008) J Am Coll Surg , vol.208
    • Ishizawa, T.1    Tamura, S.2    Masuda, K.3
  • 14
    • 53549113638 scopus 로고    scopus 로고
    • Usefulness of intraoperative fluorescence imaging to evaluate local anatomy in hepatobiliary surgery
    • Mitsuhashi N, Kimura F, Shimizu H, et al.Usefulness of intraoperative fluorescence imaging to evaluate local anatomy in hepatobiliary surgery. JHepatobiliary Pancreat Surg 2008;15:508-514.
    • (2008) J Hepatobiliary Pancreat Surg , vol.15 , pp. 508-514
    • Mitsuhashi, N.1    Kimura, F.2    Shimizu, H.3
  • 15
    • 67649411817 scopus 로고    scopus 로고
    • A novel image-guided surgery of hepatocellular carcinoma by indocyanine green fluorescence imaging navigation
    • Gotoh K, Yamada T, Ishikawa O, et al. A novel image-guided surgery of hepatocellular carcinoma by indocyanine green fluorescence imaging navigation. J Surg Oncol 2009;100:75-79.
    • (2009) J Surg Oncol , vol.100 , pp. 75-79
    • Gotoh, K.1    Yamada, T.2    Ishikawa, O.3
  • 16
    • 79952114366 scopus 로고    scopus 로고
    • Intraoperative fluorescent imaging using indocyanine green for liver mapping and cholangiography
    • AokiT,Murakami M, Yasuda D, et al. Intraoperative fluorescent imaging using indocyanine green for liver mapping and cholangiography. J Hepatobiliary Pancreat Sci 2010;17:590-594.
    • (2010) J Hepatobiliary Pancreat Sci , vol.17 , pp. 590-594
    • Aoki, T.1    Murakami, M.2    Yasuda, D.3
  • 17
    • 77952505904 scopus 로고    scopus 로고
    • Fluorescence navigation hepatectomy by visualization of localized cholestasis from bile duct tumor infiltration
    • Harada N, Ishizawa T, Muraoka A, et al. Fluorescence navigation hepatectomy by visualization of localized cholestasis from bile duct tumor infiltration. J Am Coll Surg 2010;210:e2-e6.
    • (2010) J Am Coll Surg , vol.210
    • Harada, N.1    Ishizawa, T.2    Muraoka, A.3
  • 18
    • 77952476593 scopus 로고    scopus 로고
    • Indocyanine green-fluorescent imaging of hepatocellular carcinoma during laparoscopic hepatectomy: An initial experience
    • Ishizawa T, Bandai T, N Harada, et al. Indocyanine green-fluorescent imaging of hepatocellular carcinoma during laparoscopic hepatectomy: an initial experience. Asian J Endoscop Surg 2010;3:42-45.
    • (2010) Asian J Endoscop Surg , vol.3 , pp. 42-45
    • Ishizawa, T.1    Bandai, T.2    Harada, N.3
  • 19
    • 79952109611 scopus 로고    scopus 로고
    • Surgical technique: New advances for expanding indications and increasing safety in liver resection for HCC: The Eastern perspective
    • Ishizawa T, Mise Y, Aoki T, et al. Surgical technique: new advances for expanding indications and increasing safety in liver resection for HCC: the Eastern perspective. J Hepatobiliary Pancreat Sci 2010;17:389-393.
    • (2010) J Hepatobiliary Pancreat Sci , vol.17 , pp. 389-393
    • Ishizawa, T.1    Mise, Y.2    Aoki, T.3
  • 20
    • 0017263577 scopus 로고
    • Light-absorbing properties, stability, and spectral stabilization of indocyanine green
    • Landsman ML, Kwant G, Mook GA, et al. Light-absorbing properties, stability, and spectral stabilization of indocyanine green. J Appl Physiol 1976;40:575-583.
    • (1976) J Appl Physiol , vol.40 , pp. 575-583
    • Landsman, M.L.1    Kwant, G.2    Mook, G.A.3
  • 21
    • 0031820922 scopus 로고    scopus 로고
    • Indocyanine green: Physicochemical factors affecting its fluorescence in vivo
    • DOI 10.1006/mvre.1998.2068
    • Mordon S, Devoisselle JM, Soulie-Begu S, et al. Indocyanine green: physicochemical factors affecting its fluorescence in vivo. Microvasc Res 1998;55:146-152. (Pubitemid 28368700)
    • (1998) Microvascular Research , vol.55 , Issue.2 , pp. 146-152
    • Mordon, S.1    Devoisselle, J.M.2    Soulie-Begu, S.3    Desmettre, T.4
  • 22
    • 77949279594 scopus 로고    scopus 로고
    • New device for intraoperative graft assessment: HyperEye charge-coupled device camera system
    • Handa T, Katare RG, Nishimori H, et al. New device for intraoperative graft assessment: HyperEye charge-coupled device camera system. Gen Thorac Cardiovasc Surg 2010;58: 68-77.
    • (2010) Gen Thorac Cardiovasc Surg , vol.58 , pp. 68-77
    • Handa, T.1    Katare, R.G.2    Nishimori, H.3
  • 23
    • 33645047656 scopus 로고    scopus 로고
    • Intraoperative assessment of reconstructed vessels in living-donor liver transplantation, using a novel fluorescence imaging technique
    • Kubota K, Kita J, Shimoda M, et al. Intraoperative assessment of reconstructed vessels in living-donor liver transplantation, using a novel fluorescence imaging technique. J Hepatobiliary Pancreat Surg 2006;13:100-104.
    • (2006) J Hepatobiliary Pancreat Surg , vol.13 , pp. 100-104
    • Kubota, K.1    Kita, J.2    Shimoda, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.