메뉴 건너뛰기




Volumn 34, Issue 5, 2011, Pages 531-539

Atrial fibrillation ablation: "Perpetual motion" of open irrigated tip catheters at 50 W is safe and improves outcomes

Author keywords

Atrial fibrillation; Atrial fibrillation ablation; Irrigated tip catheters

Indexed keywords

ADULT; AGED; ARTICLE; CATHETER ABLATION; CLOSED TIP CATHETER; CONTROLLED STUDY; COUGHING; ESOPHAGUS INJURY; FEMALE; FLUOROSCOPY; HEART ATRIUM FIBRILLATION; HEART BLOCK; HEART ELECTROPHYSIOLOGY; HEART TAMPONADE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; OPEN IRRIGATED TIP CATHETER; OUTCOME ASSESSMENT; PATIENT SAFETY; PERICARDIOCENTESIS; PERPETUAL MOTION; PULMONARY VALVE STENOSIS; STROKE;

EID: 79957564461     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2010.02990.x     Document Type: Article
Times cited : (60)

References (8)
  • 1
    • 40749084482 scopus 로고    scopus 로고
    • HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up
    • Calkins H, Brugada J, Packer DL, Capppato R, Chen S, Crijns H, Damiano RJ, et al. HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up. Heart Rhythm 2007; 4:1-46.
    • (2007) Heart Rhythm , vol.4 , pp. 1-46
    • Calkins, H.1    Brugada, J.2    Packer, D.L.3    Capppato, R.4    Chen, S.5    Crijns, H.6    Damiano, R.J.7
  • 3
    • 40849136307 scopus 로고    scopus 로고
    • Novel ablative approach for atrial fibrillation to decrease risk of esophageal injury
    • Bunch TJ, Day JD. Novel ablative approach for atrial fibrillation to decrease risk of esophageal injury. Heart Rhythm 2008; 5:624-627.
    • (2008) Heart Rhythm , vol.5 , pp. 624-627
    • Bunch, T.J.1    Day, J.D.2
  • 4
    • 8544236990 scopus 로고    scopus 로고
    • Analysis of catheter-tip (8-mm) and actual tissue temperatures achieved during radiofrequency ablation at the orifice of the pulmonary vein
    • DOI 10.1161/01.CIR.0000146905.19945.99
    • Bunch TJ, Bruce GK, Johnson SB, Sarabanda A, Milton MA, Packer DL. Analysis of catheter-tip (8-mm) and actual tissue temperatures achieved during radiofrequency ablation at the orifice of the pulmonary vein. Circulation 2004; 110:2988-2995. (Pubitemid 39491988)
    • (2004) Circulation , vol.110 , Issue.19 , pp. 2988-2995
    • Bunch, T.J.1    Bruce, G.K.2    Johnson, S.B.3    Sarabanda, A.4    Milton, M.A.5    Packer, D.L.6
  • 5
    • 23844511160 scopus 로고    scopus 로고
    • Discrepancies between catheter tip and tissue temperature in cooled-tip ablation. Relevance to guiding left atrial ablation
    • Bruce GK, Bunch TJ, Milton MA, Sarabanda A, Johnson SB, Packer DL. Discrepancies between catheter tip and tissue temperature in cooled-tip ablation. Relevance to guiding left atrial ablation. Circulation 2005; 112:954-960.
    • (2005) Circulation , vol.112 , pp. 954-960
    • Bruce, G.K.1    Bunch, T.J.2    Milton, M.A.3    Sarabanda, A.4    Johnson, S.B.5    Packer, D.L.6
  • 6
    • 33644869315 scopus 로고    scopus 로고
    • Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop
    • DOI 10.1161/CIRCULATIONAHA.105.540062, PII 0000301720060103000005
    • Yokoyama K, Nakagawa H, Wittkampf FHM, Pitha JV, Lazzara R, Jackman WM. Comparison of electrode cooling between internal and open irrigation in radiofrequency ablation lesion depth and incidence of thrombus and steam pop. Circulation 2006; 113:11-19. (Pubitemid 43958483)
    • (2006) Circulation , vol.113 , Issue.1 , pp. 11-19
    • Yokoyama, K.1    Nakagawa, H.2    Wittkampf, F.H.M.3    Pitha, J.V.4    Lazzara, R.5    Jackman, W.M.6
  • 7
    • 70349388083 scopus 로고    scopus 로고
    • Treatment of atrial fibrillation with antiarrhythmic drugs or radiofrequency ablation: Two systematic literature reviews and meta-analyses
    • Calkins H, Reynolds MR, Spector P, Sondhi M, Xu Y, Martin A, Williams CJ, et al. Treatment of atrial fibrillation with antiarrhythmic drugs or radiofrequency ablation: Two systematic literature reviews and meta-analyses. Circ Arrhythm Electrophysiol 2009; 2:349-361.
    • (2009) Circ Arrhythm Electrophysiol , vol.2 , pp. 349-361
    • Calkins, H.1    Reynolds, M.R.2    Spector, P.3    Sondhi, M.4    Xu, Y.5    Martin, A.6    Williams, C.J.7
  • 8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.