메뉴 건너뛰기




Volumn 49, Issue 6, 2011, Pages 2318-2320

Added value of an oropharyngeal swab in detection of viruses in children hospitalized with lower respiratory tract infection

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADENOVIRUS; ARTICLE; CONTROLLED STUDY; CORONAVIRUS; HUMAN; HUMAN METAPNEUMOVIRUS; INFLUENZA VIRUS; LOWER RESPIRATORY TRACT INFECTION; MICROBIOLOGICAL EXAMINATION; MULTIPLEX POLYMERASE CHAIN REACTION; MYCOPLASMA PNEUMONIAE; NASOPHARYNGEAL SWAB; NONHUMAN; OROPHARYNGEAL SWAB; PARAINFLUENZA VIRUS; PRIORITY JOURNAL; RESPIRATORY SYNCYTIAL PNEUMOVIRUS; RHINOVIRUS; SENSITIVITY AND SPECIFICITY; VIRUS DETECTION; VIRUS STRAIN;

EID: 79957530522     PISSN: 00951137     EISSN: 1098660X     Source Type: Journal    
DOI: 10.1128/JCM.02605-10     Document Type: Article
Times cited : (84)

References (11)
  • 1
    • 49049110966 scopus 로고    scopus 로고
    • Comparison between pernasal flocked swabs and nasopharyngeal aspirates for detection of common respiratory viruses in samples from children
    • Abu-Diab, A., et al. 2008. Comparison between pernasal flocked swabs and nasopharyngeal aspirates for detection of common respiratory viruses in samples from children. J. Clin. Microbiol. 46:2414-2417.
    • (2008) J. Clin. Microbiol. , vol.46 , pp. 2414-2417
    • Abu-Diab, A.1
  • 2
    • 70349883667 scopus 로고    scopus 로고
    • Centers for Disease Control and Prevention. October Centers for Disease Control and Prevention, Atlanta, GA
    • Centers for Disease Control and Prevention. October 2009. CDC protocol of real-time RT-PCR for influenza A (H1N1). Centers for Disease Control and Prevention, Atlanta, GA. http://www.who.int/csr/resources/publications/swineflu/ realtimeptpcr/en/index.html.
    • (2009) CDC Protocol of Real-time RT-PCR for Influenza A (H1N1)
  • 3
    • 77957808733 scopus 로고    scopus 로고
    • Comparison of midturbinate flocked-swab specimens with nasopharyngeal aspirates for detection of respiratory viruses in children by the direct fluorescent antibody technique
    • Faden, H. 2010. Comparison of midturbinate flocked-swab specimens with nasopharyngeal aspirates for detection of respiratory viruses in children by the direct fluorescent antibody technique. J. Clin. Microbiol. 48:3742-3743.
    • (2010) J. Clin. Microbiol. , vol.48 , pp. 3742-3743
    • Faden, H.1
  • 4
    • 22144499241 scopus 로고    scopus 로고
    • Real-time RT-PCR detection of 12 respiratory viral infections in four triplex reactions
    • Gunson, R. N., T. C. Collins, and W. F. Carman. 2005. Real-time RT-PCR detection of 12 respiratory viral infections in four triplex reactions. J. Clin. Virol. 33:341-344.
    • (2005) J. Clin. Virol. , vol.33 , pp. 341-344
    • Gunson, R.N.1    Collins, T.C.2    Carman, W.F.3
  • 5
    • 33751216775 scopus 로고    scopus 로고
    • Three Indonesian clusters of H5N1 virus infection in 2005
    • Kandun, I. N., et al. 2006. Three Indonesian clusters of H5N1 virus infection in 2005. N. Engl. J. Med. 355:2186-2194.
    • (2006) N. Engl. J. Med. , vol.355 , pp. 2186-2194
    • Kandun, I.N.1
  • 6
    • 70449638063 scopus 로고    scopus 로고
    • Identification of respiratory viruses in adults: Nasopharyngeal versus oropharyngeal sampling
    • Lieberman, D., A. Shimoni, A. Keren-Naus, R. Steinberg, and Y. Shemer-Avni. 2009. Identification of respiratory viruses in adults: nasopharyngeal versus oropharyngeal sampling. J. Clin. Microbiol. 47:3439-3443.
    • (2009) J. Clin. Microbiol. , vol.47 , pp. 3439-3443
    • Lieberman, D.1    Shimoni, A.2    Keren-Naus, A.3    Steinberg, R.4    Shemer-Avni, Y.5
  • 8
    • 42549161608 scopus 로고    scopus 로고
    • Use of throat swab or saliva specimens for detection of respiratory viruses in children
    • Robinson, J. L., B. E. Lee, S. Kothapalli, W. R. Craig, and J. D. Fox. 2008. Use of throat swab or saliva specimens for detection of respiratory viruses in children. Clin. Infect. Dis. 46:e61-e64.
    • (2008) Clin. Infect. Dis. , vol.46
    • Robinson, J.L.1    Lee, B.E.2    Kothapalli, S.3    Craig, W.R.4    Fox, J.D.5
  • 9
    • 77950295408 scopus 로고    scopus 로고
    • Clinical performance of a rapid influenza test and comparison of nasal versus throat swabs to detect 2009 pandemic influenza A (H1N1) infection in Thai children
    • Suntarattiwong, P., et al. 2010. Clinical performance of a rapid influenza test and comparison of nasal versus throat swabs to detect 2009 pandemic influenza A (H1N1) infection in Thai children. Pediatr. Infect. Dis. J. 29:366-367.
    • (2010) Pediatr. Infect. Dis. J. , vol.29 , pp. 366-367
    • Suntarattiwong, P.1
  • 10
    • 49049086125 scopus 로고    scopus 로고
    • Comparison of respiratory virus detection rates for infants and toddlers by use of flocked swabs, saline aspirates, and saline aspirates mixed in universal transport medium for room temperature storage and shipping
    • Walsh, P., et al. 2008. Comparison of respiratory virus detection rates for infants and toddlers by use of flocked swabs, saline aspirates, and saline aspirates mixed in universal transport medium for room temperature storage and shipping. J. Clin. Microbiol. 46:2374-2376.
    • (2008) J. Clin. Microbiol. , vol.46 , pp. 2374-2376
    • Walsh, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.