메뉴 건너뛰기




Volumn 26, Issue 3, 2011, Pages 664-673

Conservative power theory, a framework to approach control and accountability issues in smart microgrids

Author keywords

Conservative power theory (CPT); distributed control; electronic power processors; power measurement; revenue metering; smart microgrids

Indexed keywords

DISTRIBUTED CONTROL; ELECTRONIC POWER PROCESSORS; MICRO GRID; POWER MEASUREMENT; POWER THEORY; REVENUE METERING;

EID: 79957504266     PISSN: 08858993     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPEL.2010.2093153     Document Type: Article
Times cited : (233)

References (35)
  • 2
    • 0001617367 scopus 로고
    • Wirk-blind- scheinleistung in elektrische stromkreisen mit nichtsinusformingen verlauf von strom und spannung
    • 625-627, 700-702
    • S. Fryze "Wirk-, Blind-, Scheinleistung in Elektrische Stromkreisen mit Nichtsinusformingen Verlauf von Strom und Spannung," ETZ, Bd. 53, pp. 596-599, 625-627, 700-702, 1932.
    • (1932) ETZ , vol.53 , pp. 596-599
    • Fryze, S.1
  • 3
    • 0015399974 scopus 로고
    • Suggested definition of reactive power for nonsinusoidal systems
    • Sep.
    • W. Shepherd, P. Zakikhani, "Suggested definition of reactive power for nonsinusoidal systems," in Proc. Inst. Elec. Eng., vol. 119, Sep. 1972, pp. 1361-1362.
    • (1972) Proc. Inst. Elec. Eng. , vol.119 , pp. 1361-1362
    • Shepherd, W.1    Zakikhani, P.2
  • 4
    • 0023980827 scopus 로고
    • Orthogonal decomposition of the currents in a 3-phase nonlinear asymmetrical circuit with a nonsinusoidal voltage source
    • Mar.
    • L. S. Czarnecki, "Orthogonal decomposition of the currents in a 3-phase nonlinear asymmetrical circuit with a nonsinusoidal voltage source," IEEE Trans. Instrum. Meas., vol. IM-37, no. 1, pp. 30-34, Mar. 1988.
    • (1988) IEEE Trans. Instrum. Meas. , vol.IM-37 , Issue.1 , pp. 30-34
    • Czarnecki, L.S.1
  • 5
    • 46749146396 scopus 로고    scopus 로고
    • A time-domain approach to power term definitions under non-sinusoidal conditions
    • P. Tenti and P. Mattavelli, "A time-domain approach to power term definitions under non-sinusoidal conditions," L'Energia Elettrica, vol. 81, pp. 75-84, 2004.
    • (2004) L'Energia Elettrica , vol.81 , pp. 75-84
    • Tenti, P.1    Mattavelli, P.2
  • 6
    • 34147130814 scopus 로고    scopus 로고
    • Currents' physical components (CPC) in circuits with nonsinusoidal voltages and currents. Part 1: Single-phase linear circuits
    • L. S. Czarnecki, "Currents' physical components (CPC) in circuits with nonsinusoidal voltages and currents. Part 1: Single-phase linear circuits," Electr. Power Qual. Utilizat. J., vol. XI, no. 2, pp. 3-14, 2005.
    • (2005) Electr. Power Qual. Utilizat. J. , vol.11 , Issue.2 , pp. 3-14
    • Czarnecki, L.S.1
  • 7
    • 0023567816 scopus 로고
    • Power factor correction for distorted bus voltages
    • J. L.Willems, "Power factor correction for distorted bus voltages," Electr. Mach. Power Syst., vol. 13, no. 4, pp. 207-218, 1987. (Pubitemid 18519352)
    • (1987) Electric Machines and Power Systems , vol.13 , Issue.4 , pp. 207-218
    • Willems, J.L.1
  • 8
    • 0027149201 scopus 로고
    • Power factor improvement of three-phase unbalanced loads with nonsinusoidal supply voltages
    • Jan./Feb.
    • L. S. Czarnecki, "Power factor improvement of three-phase unbalanced loads with nonsinusoidal supply voltages," ETEP Eur. Trans. Electr. Power Eng., vol. 3, no. 1, pp. 67-72, Jan./Feb. 1993.
    • (1993) ETEP Eur. Trans. Electr. Power Eng. , vol.3 , Issue.1 , pp. 67-72
    • Czarnecki, L.S.1
  • 9
    • 0020885127 scopus 로고
    • Generalized theory of the instantaneous reactive power in three-phase circuits
    • H. Akagi, Y. Kanazawa, and A. Nabae, "Generalized theory of the instantaneous reactive power in three-phase circuits," in Proc. Int. Power Electr. Conf., Tokyo/Japan, 1983, pp. 1375-1386. (Pubitemid 14595897)
    • (1983) Proc. Int. Power Electr. Conf. , vol.2 , pp. 1375-1386
    • Akagi, H.1    Kanazawa, Y.2    Nabae, A.3
  • 10
    • 0021429788 scopus 로고
    • Instantaneous reactive power compensators comprising switching devices without energy storage components
    • H. Akagi, Y. Kanazawa, and A. Nabae, "Instantaneous reactive power compensators comprising switching devices without energy storage components," IEEE Trans. Ind. Appl., vol. IA-20, no. 3, pp. 625-630, May/Jun. 1984. (Pubitemid 14621229)
    • (1984) IEEE Transactions on Industry Applications , vol.IA-20 , Issue.3 , pp. 625-630
    • Akagi, H.1    Kanazawa, Y.2    Nabae, A.3
  • 11
    • 0027593295 scopus 로고
    • FBD-method, a generally applicable tool for analyzing power relations
    • DOI 10.1109/59.260849
    • M. Depenbrock, "The FBD-method, A generally applicable tool for analyzing power relations," IEEE Trans. Power Syst., vol. 8, no. 2, pp. 381-387, May 1993. (Pubitemid 23699335)
    • (1993) IEEE Transactions on Power Systems , vol.8 , Issue.2 , pp. 381-387
    • Depenbrock, M.1
  • 12
    • 0000111102 scopus 로고    scopus 로고
    • Mathematical foundations of the instantaneous power concepts: An algebraic approach
    • L. Cristaldi and A. Ferrero, "Mathematical foundations of the instantaneous power concept: An algebraic approach," ETEP Eur. Trans. Electr. Power, vol. 6, no. 5, pp. 305-309, Sep./Oct. 1996. (Pubitemid 126765936)
    • (1996) European Transactions on Electrical Power , vol.6 , Issue.5 , pp. 305-309
    • Cristaldi, L.1    Ferrero, A.2
  • 13
    • 0032635681 scopus 로고    scopus 로고
    • A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line
    • May/Jun.
    • H. Akagi, H. Fujita, and K. Wada, "A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line," IEEE Trans. Ind. Appl., vol. 35, no. 3, pp. 638-645, May/Jun. 1999.
    • (1999) IEEE Trans. Ind. Appl. , vol.35 , Issue.3 , pp. 638-645
    • Akagi, H.1    Fujita, H.2    Wada, K.3
  • 14
    • 0038692369 scopus 로고    scopus 로고
    • Implementation and performance of cooperative control of shunt active filters for harmonic damping throughout a power distribution system
    • Mar./Apr.
    • P. Jintakosonwit, H. Fujita, H. Akagi, and S. Ogasawara, "Implementation and performance of cooperative control of shunt active filters for harmonic damping throughout a power distribution system," IEEE Trans. Ind. Appl., vol. 39, no. 2, pp. 556-563, Mar./Apr. 2003.
    • (2003) IEEE Trans. Ind. Appl. , vol.39 , Issue.2 , pp. 556-563
    • Jintakosonwit, P.1    Fujita, H.2    Akagi, H.3    Ogasawara, S.4
  • 15
    • 33646377655 scopus 로고    scopus 로고
    • Analysis of harmonic damping effect of the distributed active filter system
    • May
    • P. T. Cheng and T. L. Lee, "Analysis of harmonic damping effect of the distributed active filter system," IEEE Trans. Ind. Appl., vol. 126, no. 5, pp. 605-614, May 2006.
    • (2006) IEEE Trans. Ind. Appl. , vol.126 , Issue.5 , pp. 605-614
    • Cheng, P.T.1    Lee, T.L.2
  • 16
    • 72949085455 scopus 로고    scopus 로고
    • Compensation techniques based on reactive power conservation
    • P. Tenti, E. Tedeschi, and P. Mattavelli, "Compensation techniques based on reactive power conservation," Electr. Power Qual. Utilizat., vol. XIII, no. 1, pp. 17-24, 2007.
    • (2007) Electr. Power Qual. Utilizat. , vol.13 , Issue.1 , pp. 17-24
    • Tenti, P.1    Tedeschi, E.2    Mattavelli, P.3
  • 17
    • 33749402651 scopus 로고    scopus 로고
    • Distributed active filter systems (DAFS): A new approach to power systems harmonics
    • Sep./Oct.
    • P. T. Cheng and T. L. Lee, "Distributed active filter systems (DAFS): A new approach to power systems harmonics," IEEE Trans. Ind. Appl., vol. 42, no. 5, pp. 1301-1309, Sep./Oct. 2006.
    • (2006) IEEE Trans. Ind. Appl. , vol.42 , Issue.5 , pp. 1301-1309
    • Cheng, P.T.1    Lee, T.L.2
  • 20
    • 77949930853 scopus 로고    scopus 로고
    • Cooperative control of electronic power processors in micro-grids
    • Nov.
    • E. Tedeschi, P. Tenti, P. Mattavelli, andD. Trombetti, "Cooperative control of electronic power processors in micro-grids," Braz. J. Power Electron., vol. 14, pp. 241-249, Nov. 2009.
    • (2009) Braz. J. Power Electron. , vol.14 , pp. 241-249
    • Tedeschi, E.1    Tenti, P.2    Mattavelli, P.3    Trombetti, D.4
  • 23
    • 0018008524 scopus 로고
    • Principles and applications of static, thyristor-controlled, shunt compensators
    • L. Gyugyi, R. A. Otto, and T. H. Putman, "Principles and applications of static, thyristor-controlled, shunt compensators," IEEE Trans. Power App. Syst., vol. PAS-97, no. 5, pp. 1935-1945, Sep./Oct. 1978. (Pubitemid 9394020)
    • (1978) IEEE Trans Power Appar Syst , vol.PAS-97 , Issue.5 , pp. 1935-1945
    • Gyugyi, L.1    Otto, R.2    Putman, T.H.3
  • 24
    • 72949091367 scopus 로고    scopus 로고
    • Generalized symmetrical components for periodic non-sinusoidal three-phase signals
    • P Tenti, J. L. Willems, P. Mattavelli, and E. Tedeschi, "Generalized symmetrical components for periodic non-sinusoidal three-phase signals," Electr. Power Qual. Utilizat., vol. XIII, no. 1, pp. 9-15, 2007.
    • (2007) Electr. Power Qual. Utilizat. , vol.13 , Issue.1 , pp. 9-15
    • Tenti, P.1    Willems, J.L.2    Mattavelli, P.3    Tedeschi, E.4
  • 25
    • 77953255196 scopus 로고    scopus 로고
    • Conservative power theory, sequence components and accountability in smart grids
    • P. Tenti, P. Mattavelli, H. K. Morales, and Paredes, "Conservative power theory, sequence components and accountability in smart grids," Prz. Elektrotech., vol. 6, pp. 30-37, 2010.
    • (2010) Prz. Elektrotech. , vol.6 , pp. 30-37
    • Tenti, P.1    Mattavelli, P.2    Morales, H.K.3    Paredes4
  • 26
    • 0029250932 scopus 로고
    • A digital method for the identification of the source of distortion in electric power systems
    • Feb.
    • L. Cristaldi and A. Ferrero, "A digital method for the identification of the source of distortion in electric power systems," IEEE Trans. Instrum. Meas., vol. 44, no. 1, pp. 14-18, Feb. 1994.
    • (1994) IEEE Trans. Instrum. Meas. , vol.44 , Issue.1 , pp. 14-18
    • Cristaldi, L.1    Ferrero, A.2
  • 27
    • 1942472040 scopus 로고    scopus 로고
    • A critical impedance-based method for identifying harmonic sources
    • Apr.
    • C. Li, W. Xu, and T. Tayjasant, "A critical impedance-based method for identifying harmonic sources," IEEE Trans. Power Del., vol. 19, no. 2, pp. 671-678, Apr. 2004.
    • (2004) IEEE Trans. Power Del. , vol.19 , Issue.2 , pp. 671-678
    • Li, C.1    Xu, W.2    Tayjasant, T.3
  • 29
    • 74949098761 scopus 로고    scopus 로고
    • Experimental investigation of existing methodologies for the responsibility assignment problem
    • Bucharest, Romania, Jun./Jul.
    • A. Pavas, V. Staudt, and H. Torres-Sánchez, "Experimental investigation of existing methodologies for the responsibility assignment problem," in Proc. IEEE Power Tech., Bucharest, Romania, Jun./Jul.2009.
    • (2009) Proc. IEEE Power Tech.
    • Pavas, A.1    Staudt, V.2    Torres-Sánchez, H.3
  • 30
    • 43649091995 scopus 로고    scopus 로고
    • A large role for microgrids, Are microgrids a viable paradigm for electricity supply expansion?
    • May/Jun.
    • G. Venkataramann and C. Marnay, "A large role for microgrids, "Are microgrids a viable paradigm for electricity supply expansion?" IEEE Power Energy Mag., pp. 78-82, May/Jun. 2008.
    • (2008) IEEE Power Energy Mag. , pp. 78-82
    • Venkataramann, G.1    Marnay, C.2
  • 31
    • 43649086972 scopus 로고    scopus 로고
    • Policymaking for microgrids: Economic and regulatory issues of microgrid implementation
    • May/Jun.
    • C. Marnay, H. Asano, S. Papathanassiou, and G. Strbac, "Policymaking for microgrids: Economic and regulatory issues of microgrid implementation," IEEE Power Energy Mag., pp. 66-77, May/Jun. 2008.
    • (2008) IEEE Power Energy Mag. , pp. 66-77
    • Marnay, C.1    Asano, H.2    Papathanassiou, S.3    Strbac, G.4
  • 32
    • 57349138926 scopus 로고    scopus 로고
    • Energy management in autonomous microgrid using stability-constrained droop control of inverters
    • Sep.
    • E. Barklund, N. Pogaku, M. Prodanovic, C. Hernandez-Aramburo, and T. C. Green, "Energy management in autonomous microgrid using stability-constrained droop control of inverters," IEEE Trans. Power Electron., vol. 23, no. 5, pp. 2346-2352, Sep. 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.5 , pp. 2346-2352
    • Barklund, E.1    Pogaku, N.2    Prodanovic, M.3    Hernandez-Aramburo, C.4    Green, T.C.5
  • 33
    • 59749094251 scopus 로고    scopus 로고
    • Adaptive decentralized droop controller to preserve power sharing stability of paralleled inverters in distributed generation microgrids
    • Nov.
    • Y. A.-R. I. Mohamed and E. F. El-Saadany, "Adaptive decentralized droop controller to preserve power sharing stability of paralleled inverters in distributed generation microgrids," IEEE Trans. Power Electron., vol. 23, no. 6, pp. 2806-2816, Nov. 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.6 , pp. 2806-2816
    • Mohamed, Y.A.-R.I.1    El-Saadany, E.F.2
  • 34
    • 74349104711 scopus 로고    scopus 로고
    • An accurate power control strategy for powerelectronics-interfaced distributed generation units operating in a lowvoltagemultibus microgrid
    • Dec.
    • Y. W. Li and C.-N. Kao, "An accurate power control strategy for powerelectronics-interfaced distributed generation units operating in a lowvoltagemultibus microgrid," IEEE Trans. Power Electron., vol. 24, no. 12, pp. 2977-2988, Dec. 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.12 , pp. 2977-2988
    • Li, Y.W.1    Kao, C.-N.2
  • 35
    • 33746901214 scopus 로고    scopus 로고
    • A grid-interfacing power quality compensator for three-phase three-wire microgrid applications
    • DOI 10.1109/TPEL.2006.876844
    • Y. W. Li, D. M. Vilathgamuwa, and P. C. Loh, "A grid-interfacing power quality compensator for three-phase three-wire microgrid applications," IEEE Trans. Power Electron., vol. 21, no. 4, pp. 1021-1031, Jul. 2006. (Pubitemid 44194187)
    • (2006) IEEE Transactions on Power Electronics , vol.21 , Issue.4 , pp. 1021-1031
    • Li, Y.W.1    Vilathgamuwa, D.M.2    Loh, P.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.