메뉴 건너뛰기




Volumn 26, Issue 2, 2011, Pages 513-521

On active/reactive power modulation of DFIG-based wind generation for interarea oscillation damping

Author keywords

Active power modulation; doubly fed induction generator (DFIG); interarea oscillation damping; reactive power modulation

Indexed keywords

ACTIVE POWER; DOUBLY-FED INDUCTION GENERATOR; INTER-AREA OSCILLATIONS; INTERAREA OSCILLATION DAMPING; LINEAR SYSTEM ANALYSIS; MATLAB /SIMULINK; POWER MODULATION; REACTIVE POWER MODULATION; SIMULATION RESULT; STUDY CASE; TORSIONAL DYNAMICS; WIND GENERATION; WIND GENERATORS;

EID: 79957489770     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2010.2089985     Document Type: Article
Times cited : (170)

References (22)
  • 1
    • 0024751423 scopus 로고
    • Power modulation of Sidney HVDC scheme - I: RAS control concept, realization and field tests
    • DOI 10.1109/61.35641
    • R. Johnson, N. Klemm, H. D. Laneuville, S. Koetschau, and G. Wild, "Power modulation of Sidney HVDC scheme-Part I: RAS control concept, realization and field tests," IEEE Trans. Power Del., vol. 4, no. 4, pp. 2145-2152, Oct. 1989. (Pubitemid 20618416)
    • (1989) IEEE Transactions on Power Delivery , vol.4 , Issue.4 , pp. 2145-2152
    • Johnson, R.K.1    Klemm, N.S.2    Laneuville, H.D.3    Koetschau, S.G.4    Wild, G.5
  • 3
    • 0037843084 scopus 로고    scopus 로고
    • Comparison of PSS, SVC, and STATCOM controllers for damping power system oscillations
    • May
    • N. Mithulananthan, C. Canizares, J. Reeve, and G. Rogers, "Comparison of PSS, SVC, and STATCOM controllers for damping power system oscillations," IEEE Trans. Power Syst., vol. 18, no. 2, pp. 786-792, May 2003.
    • (2003) IEEE Trans. Power Syst. , vol.18 , Issue.2 , pp. 786-792
    • Mithulananthan, N.1    Canizares, C.2    Reeve, J.3    Rogers, G.4
  • 4
    • 66849108936 scopus 로고    scopus 로고
    • Control of DFIG-based wind generation to improve inter-area oscillation damping
    • Jun.
    • Z. Miao, L. Fan, D. Osborn, and S. Yuvarajan, "Control of DFIG-based wind generation to improve inter-area oscillation damping," IEEE Trans. Energy Convers., vol. 24, no. 2, pp. 415-422, Jun. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.2 , pp. 415-422
    • Miao, Z.1    Fan, L.2    Osborn, D.3    Yuvarajan, S.4
  • 6
    • 70049083223 scopus 로고    scopus 로고
    • Improving stability of a DFIG-based wind power system with tuned damping controller
    • Sep.
    • Y. Mishra, S. Mishra, M. Tripathy, N. Senroy, and Z. Dong, "Improving stability of a DFIG-based wind power system with tuned damping controller," IEEE Trans. Energy Convers., vol. 24, no. 3, pp. 650-660, Sep. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.3 , pp. 650-660
    • Mishra, Y.1    Mishra, S.2    Tripathy, M.3    Senroy, N.4    Dong, Z.5
  • 7
    • 70049105469 scopus 로고    scopus 로고
    • Contribution of doubly fed wind generators to oscillation damping
    • Sep.
    • G. Tsourakis, B. M. Nomikos, and C. D. Vournas, "Contribution of doubly fed wind generators to oscillation damping," IEEE Trans. Energy Convers., vol. 24, no. 3, pp. 783-791, Sep. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.3 , pp. 783-791
    • Tsourakis, G.1    Nomikos, B.M.2    Vournas, C.D.3
  • 9
    • 0038043135 scopus 로고    scopus 로고
    • Modeling and control of a wind turbine driven doubly fed induction generator
    • Jun.
    • A. Tapia, G. Tapia, J. X. Ostolaza, and J. R. Saenz, "Modeling and control of a wind turbine driven doubly fed induction generator," IEEE Trans. Energy Convers., vol. 18, pp. 194-204, Jun. 2003.
    • (2003) IEEE Trans. Energy Convers. , vol.18 , pp. 194-204
    • Tapia, A.1    Tapia, G.2    Ostolaza, J.X.3    Saenz, J.R.4
  • 10
    • 0036575603 scopus 로고    scopus 로고
    • Doubly fed induction generator systems for wind turbines
    • DOI 10.1109/2943.999610
    • S. Muller, M. Deicke, and R. W. D. Doncker, "Doubly fed induction generator systems for wind turbine," IEEE Ind. Appl. Mag., pp. 26-33, May/Jun. 2002. (Pubitemid 34630524)
    • (2002) IEEE Industry Applications Magazine , vol.8 , Issue.3 , pp. 26-33
    • Muller, S.1    Deicke, M.2    De Doncker, R.W.3
  • 12
    • 78649577919 scopus 로고    scopus 로고
    • Reactive powermodulation for inter-area oscillation damping of DFIG-based wind generation
    • Minneapolis, US, Jul.
    • H.Yin, L. Fan, and Z.Miao, "Reactive powermodulation for inter-area oscillation damping of DFIG-based wind generation," in Proc. IEEE Power Energy Soc. General Meeting, Minneapolis, US, Jul. 2010, pp. 1-9.
    • (2010) Proc. IEEE Power Energy Soc. General Meeting , pp. 1-9
    • Yin, H.1    Fan, L.2    Miao, Z.3
  • 14
    • 52349114231 scopus 로고    scopus 로고
    • Modelling of doubly fed induction generator for power system stability study
    • Jul.
    • F. Mei and B. C. Pal, "Modelling of doubly fed induction generator for power system stability study," in Proc. IEEE Power Energy General Meeting, Jul. 2008, pp. 181-190.
    • (2008) Proc. IEEE Power Energy General Meeting , pp. 181-190
    • Mei, F.1    Pal, B.C.2
  • 15
    • 53349103935 scopus 로고    scopus 로고
    • The art of modeling high-order induction generators in wind generation applications
    • Oct.
    • Z. Miao and L. Fan, "The art of modeling high-order induction generators in wind generation applications," Simul. Model. Practice Theory, vol. 16, pp. 1239-1253, Oct. 2008.
    • (2008) Simul. Model. Practice Theory , vol.16 , pp. 1239-1253
    • Miao, Z.1    Fan, L.2
  • 16
    • 49949099791 scopus 로고    scopus 로고
    • Transient stability analysis of wind turbines with induction generators considering blades and shaft flexibility
    • Nov., Taipei, Taiwan
    • H. Li and Z. Chen, "Transient stability analysis of wind turbines with induction generators considering blades and shaft flexibility," in Proc. 33rd Annu. Conf. IEEE Ind. Electron. Soc. (IECON), Taipei, Taiwan, Nov. 2007, pp. 1604-1609.
    • (2007) Proc. 33rd Annu. Conf. IEEE Ind. Electron. Soc. (IECON) , pp. 1604-1609
    • Li, H.1    Chen, Z.2
  • 17
    • 44449152969 scopus 로고    scopus 로고
    • Wind speed estimation based sensorless output maximization control for a wind turbine driving a DFIG
    • DOI 10.1109/TPEL.2008.921185
    • W. Qiao, W. Zhou, J. Aller, and R. Harley, "Wind speed estimation based sensorless output maximization control for a wind turbine driving a DFIG," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1156-1169, May 2008. (Pubitemid 351756691)
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.3 , pp. 1156-1169
    • Qiao, W.1    Zhou, W.2    Aller, J.M.3    Harley, R.G.4
  • 19
    • 0037189257 scopus 로고    scopus 로고
    • Selection and design of a TCSC control signal in damping power system inter-area oscillations for multiple operating conditions
    • DOI 10.1016/S0378-7796(02)00039-1, PII S0378779602000391
    • L. Fan, A. Feliachi, and K. Schoder, "Selection and design of a TCSC control signal in damping power system inter-area oscillations formultiple operating conditions," Electr. Power Syst. Res., vol. 62, no. 2, pp. 127-137, Jun. 2002. (Pubitemid 34716043)
    • (2002) Electric Power Systems Research , vol.62 , Issue.2 , pp. 127-137
    • Fan, L.1    Feliachi, A.2    Schoder, K.3
  • 20
    • 0029305206 scopus 로고
    • Concepts for design of FACTS controllers to damp power swings
    • May
    • E. Larsen, J. Sanchez-Gasca, and J. Chow, "Concepts for design of FACTS controllers to damp power swings," IEEE Trans. Power Syst., vol. 10, no. 2, pp. 948-956, May 1995.
    • (1995) IEEE Trans. Power Syst. , vol.10 , Issue.2 , pp. 948-956
    • Larsen, E.1    Sanchez-Gasca, J.2    Chow, J.3
  • 21
    • 77951665975 scopus 로고    scopus 로고
    • Optimized partial eigenstructure assignment-based design of a combined PSS and active damping controller for a DFIG
    • May
    • N. Kshatriya, U. D. Annakkage, F. Hughes, and A. M. Gole, "Optimized partial eigenstructure assignment-based design of a combined PSS and active damping controller for a DFIG," IEEE Trans. Power Syst., vol. 25, no. 2, pp. 866-876, May 2010.
    • (2010) IEEE Trans. Power Syst. , vol.25 , Issue.2 , pp. 866-876
    • Kshatriya, N.1    Annakkage, U.D.2    Hughes, F.3    Gole, A.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.