메뉴 건너뛰기




Volumn 27, Issue 4, 2011, Pages 415-424

Improving the performance of CUSUM charts

Author keywords

average run length (ARL); control charts; EWMA; in control; out of control; runs rules schemes

Indexed keywords

AVERAGE RUN LENGTHS; CONTROL CHARTS; EWMA; IN-CONTROL; OUT-OF-CONTROL; RUNS RULES;

EID: 79957479644     PISSN: 07488017     EISSN: 10991638     Source Type: Journal    
DOI: 10.1002/qre.1124     Document Type: Article
Times cited : (95)

References (18)
  • 3
    • 0002916530 scopus 로고
    • Continuous inspection schemes
    • Page ES,. Continuous inspection schemes. Biometrika 1954; 41: 100-115.
    • (1954) Biometrika , vol.41 , pp. 100-115
    • Page, E.S.1
  • 5
    • 0020165826 scopus 로고
    • Fast initial response for CUSUM quality-control scheme
    • Lucas JM, Crosier RB,. Fast initial response for CUSUM quality-control scheme. Technometrics 1982; 24: 199-205.
    • (1982) Technometrics , vol.24 , pp. 199-205
    • Lucas, J.M.1    Crosier, R.B.2
  • 6
    • 0021514376 scopus 로고
    • The Shewhart control chart-Tests for special causes
    • Nelson LS,. The Shewhart control chart-Tests for special causes. Journal of Quality Technology 1984; 16: 237-239.
    • (1984) Journal of Quality Technology , vol.16 , pp. 237-239
    • Nelson, L.S.1
  • 7
    • 0038723914 scopus 로고    scopus 로고
    • Two Alternatives to the Shewhart X control chart
    • Klein M,. Two Alternatives to the Shewhart X control chart. Journal of Quality Technology 2000; 32: 427-431.
    • (2000) Journal of Quality Technology , vol.32 , pp. 427-431
    • Klein, M.1
  • 8
    • 0141954019 scopus 로고    scopus 로고
    • Design of runs rules schemes
    • Khoo MBC,. Design of runs rules schemes. Quality Engineering 2004; 16: 27-43.
    • (2004) Quality Engineering , vol.16 , pp. 27-43
    • Khoo, M.B.C.1
  • 12
    • 0017742267 scopus 로고
    • Combined Shewhart cusum control chart for improved quality control in clinical chemistry
    • Westgard JO, Groth T, Aronsson T, De Verdier CH,. Combined Shewhart-CUSUM control chart for improved quality control in clinical chemistry. Clinical Chemistry 1977; 23 (10): 1881-1887. (Pubitemid 8198540)
    • (1977) Clinical Chemistry , vol.23 , Issue.10 , pp. 1881-1887
    • Westgard, J.O.1    Groth, T.2    Aronsson, T.3    De Verdier, C.H.4
  • 13
    • 0001393743 scopus 로고
    • An approach to the probability distribution of CUSUM run length
    • Brook D, Evans DA,. An approach to the probability distribution of CUSUM run length. Biometrika 1972; 59: 539-549.
    • (1972) Biometrika , vol.59 , pp. 539-549
    • Brook, D.1    Evans, D.A.2
  • 14
    • 0000025672 scopus 로고
    • Tables of run length percentiles for determining the sensitivity of Shewhart control charts for averages with supplementary runs rules
    • Palm AC,. Tables of run length percentiles for determining the sensitivity of Shewhart control charts for averages with supplementary runs rules. Journal of Quality Technology 1990; 22: 289-298.
    • (1990) Journal of Quality Technology , vol.22 , pp. 289-298
    • Palm, A.C.1
  • 15
  • 16
    • 18544385420 scopus 로고
    • Weighted cumulative sum technique
    • Yashchin E,. Weighted cumulative sum technique. Technometrics 1989; 31 (1): 321-338.
    • (1989) Technometrics , vol.31 , Issue.1 , pp. 321-338
    • Yashchin, E.1
  • 17
    • 0023453803 scopus 로고
    • A simple method for studying run-length distributions of exponentially weighted moving average charts
    • Crowder SV,. A simple method for studying run-length distributions of exponentially weighted moving average charts. Technometrics 1987; 29 (4): 401-407.
    • (1987) Technometrics , vol.29 , Issue.4 , pp. 401-407
    • Crowder, S.V.1
  • 18
    • 0033842344 scopus 로고    scopus 로고
    • Improving time-sensitive processes in the intensive care unit the example of 'door-to-needle time' in acute myocardial infarction
    • DOI 10.1093/intqhc/12.4.311
    • Bonetti PO, Waeckerlin A, Schuepfer G, Frutiger A,. Improving time-sensitive processes in the intensive care unit: The example of 'Door-to-Needle Time' in acute myocardial infarction. International Journal for Quality in Health Care 2000; 12 (4): 311-317. (Pubitemid 30663850)
    • (2000) International Journal for Quality in Health Care , vol.12 , Issue.4 , pp. 311-317
    • Bonetti, P.O.1    Waeckerlin, A.2    Schuepfer, G.3    Frutiger, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.