메뉴 건너뛰기




Volumn 6, Issue 1, 2011, Pages 47-59

Online monitoring of pharmaceutical materials using multiple NIR sensors-Part I: Blend homogeneity

Author keywords

Blending; Calibration transfer; Classical least squares; Homogeneity; Near infrared spectroscopy; Pharmaceutical; Standardization

Indexed keywords

ARTICLE; CALIBRATION; CONTROL SYSTEM; NEAR INFRARED SPECTROSCOPY; NOISE REDUCTION; ONLINE MONITORING; PHARMACEUTICAL ENGINEERING; PRIORITY JOURNAL; PROCESS OPTIMIZATION; SEMI AUTOMATED BLEND HOMOGENEITY CONTROL SYSTEM; SENSOR; STANDARDIZATION; VALIDATION PROCESS;

EID: 79956367649     PISSN: 18725120     EISSN: 19398042     Source Type: Journal    
DOI: 10.1007/s12247-011-9099-1     Document Type: Article
Times cited : (35)

References (34)
  • 2
    • 0030217890 scopus 로고    scopus 로고
    • Near-infrared spectroscopic characterization of pharmaceutical powder blends
    • DOI 10.1016/0731-7085(96)01739-6
    • D Wargo JK Drennen 1996 Near-infrared spectroscopic characterization of pharmaceutical powder blends J Pharm Biomed Anal 14 1415 1423 8877847 10.1016/0731-7085(96)01739-6 1:CAS:528:DyaK28XlsFKqtbg%3D (Pubitemid 26279287)
    • (1996) Journal of Pharmaceutical and Biomedical Analysis , vol.14 , Issue.11 , pp. 1415-1423
    • Wargo, D.J.1    Drennen, J.K.2
  • 3
  • 4
    • 64549088926 scopus 로고    scopus 로고
    • Quality-by-Design (QbD): An integrated multivariate approach for the component quantification in powder blends
    • 19437592 10.1016/j.ijpharm.2009.01.002 1:CAS:528:DC%2BD1MXks12isLk%3D
    • H Wu M Tawakkul M White MA Khan 2009 Quality-by-Design (QbD): an integrated multivariate approach for the component quantification in powder blends Int J Pharm 372 39 48 19437592 10.1016/j.ijpharm.2009.01.002 1:CAS:528:DC%2BD1MXks12isLk%3D
    • (2009) Int J Pharm , vol.372 , pp. 39-48
    • Wu, H.1    Tawakkul, M.2    White, M.3    Khan, M.A.4
  • 6
    • 0032582289 scopus 로고    scopus 로고
    • Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy. Part II. Qualitative approaches to blend evaluation
    • DOI 10.1016/S0731-7085(98)00025-9, PII S0731708598000259
    • SS Sekulic J Wakeman P Doherty PA Hailey 1998 Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy Part II, qualitative approaches to blend evaluation J Pharm Biomed Anal 17 1285 1309 9800649 10.1016/S0731-7085(98)00025-9 1:CAS:528:DyaK1cXmsFamtLk%3D (Pubitemid 29027737)
    • (1998) Journal of Pharmaceutical and Biomedical Analysis , vol.17 , Issue.8 , pp. 1285-1309
    • Sekulic, S.S.1    Wakeman, J.2    Doherty, P.3    Hailey, P.A.4
  • 8
    • 32644437395 scopus 로고    scopus 로고
    • A process analytical technology approach to near-infrared process control of pharmaceutical powder blending: Part II: Qualitative near-infrared models for prediction of blend homogeneity
    • DOI 10.1002/jps.20466
    • AS El-Hagrasy M Delgado-Lopez JK Drennen 2006 A process analytical technology approach to near-infrared process control of pharmaceutical powder blending: part II: qualitative near-infrared models for prediction of blend homogeneity J Pharm Sci 95 407 421 16380974 10.1002/jps.20466 1:CAS:528:DC%2BD28XhsFeks7k%3D (Pubitemid 43241982)
    • (2006) Journal of Pharmaceutical Sciences , vol.95 , Issue.2 , pp. 407-421
    • El-Hagrasy, A.S.1    Delgado-Lopez, M.2    Drennen III, J.K.3
  • 9
    • 0037061158 scopus 로고    scopus 로고
    • Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy
    • DOI 10.1016/S0032-5910(01)00456-9, PII S0032591001004569
    • O Berntsson LG Danielsson B Lagerholm S Folestad 2002 Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy Powder Technol 123 185 193 10.1016/S0032-5910(01)00456-9 1:CAS:528: DC%2BD38Xhs1yms7c%3D (Pubitemid 34203569)
    • (2002) Powder Technology , vol.123 , Issue.2-3 , pp. 185-193
    • Berntsson, O.1    Danielsson, L.-G.2    Lagerholm, B.3    Folestad, S.4
  • 10
    • 33645055644 scopus 로고    scopus 로고
    • Simple assessment of homogeneity in pharmaceutical mixing processes using a near-infrared reflectance probe and control charts
    • 16289623 10.1016/j.jpba.2005.10.009 1:CAS:528:DC%2BD28Xis1entb0%3D
    • ETS Skibsted HFM Boelens JA Westerhuis DT Witte AK Smilde 2006 Simple assessment of homogeneity in pharmaceutical mixing processes using a near-infrared reflectance probe and control charts J Pharm Biomed Anal 41 26 35 16289623 10.1016/j.jpba.2005.10.009 1:CAS:528:DC%2BD28Xis1entb0%3D
    • (2006) J Pharm Biomed Anal , vol.41 , pp. 26-35
    • Skibsted, E.T.S.1    Boelens, H.F.M.2    Westerhuis, J.A.3    Witte, D.T.4    Smilde, A.K.5
  • 11
    • 44749088589 scopus 로고    scopus 로고
    • Process characterization of powder blending by near-infrared spectroscopy: Blend end-points and beyond
    • 18486399 10.1016/j.jpba.2008.03.013 1:CAS:528:DC%2BD1cXntlSmtrg%3D
    • Z Shi RP Cogdill SM Short CA Anderson 2008 Process characterization of powder blending by near-infrared spectroscopy: blend end-points and beyond J Pharm Biomed Anal 47 738 745 18486399 10.1016/j.jpba.2008.03.013 1:CAS:528:DC%2BD1cXntlSmtrg%3D
    • (2008) J Pharm Biomed Anal , vol.47 , pp. 738-745
    • Shi, Z.1    Cogdill, R.P.2    Short, S.M.3    Anderson, C.A.4
  • 12
    • 0030929920 scopus 로고    scopus 로고
    • Effective mass sampled by NIR fiber-optic reflectance probes in blending processes
    • DOI 10.1016/S0003-2670(97)00094-9, PII S0003267097000949
    • JH Cho PJ Gemperline PK Aldridge SS Sekulic 1997 Effective mass sampled by NIR fiber-optic reflectance probes in blending process Anal Chim Acta 348 303 310 10.1016/S0003-2670(97)00094-9 1:CAS:528:DyaK2sXlsVWhu7k%3D (Pubitemid 27397439)
    • (1997) Analytica Chimica Acta , vol.348 , Issue.1-3 , pp. 303-310
    • Cho, J.1    Gemperline, P.J.2    Aldridge, P.K.3    Sekulic, S.S.4
  • 13
    • 0036869725 scopus 로고    scopus 로고
    • Determination of the information depth and sample size for the analysis of pharmaceutical materials using reflectance near-infrared microscopy
    • 10.1366/00037020260377797 1:CAS:528:DC%2BD38XptVensr4%3D
    • FC Clarke SV Hammond RD Jee AC Moffat 2002 Determination of the information depth and sample size for the analysis of pharmaceutical materials using reflectance near-infrared microscopy Appl Spectrosc 56 1475 1483 10.1366/00037020260377797 1:CAS:528:DC%2BD38XptVensr4%3D
    • (2002) Appl Spectrosc , vol.56 , pp. 1475-1483
    • Clarke, F.C.1    Hammond, S.V.2    Jee, R.D.3    Moffat, A.C.4
  • 14
    • 0026360726 scopus 로고
    • Powder mixing: Some practical rules applied to agitated systems
    • 10.1016/0032-5910(91)80047-M 1:CAS:528:DyaK38XhslKlsbo%3D
    • M Poux JB Fayolle D Bridoux J Bousquet 1991 Powder mixing: some practical rules applied to agitated systems Powder Technol 68 213 234 10.1016/0032-5910(91)80047-M 1:CAS:528:DyaK38XhslKlsbo%3D
    • (1991) Powder Technol , vol.68 , pp. 213-234
    • Poux, M.1    Fayolle, J.B.2    Bridoux, D.3    Bousquet, J.4
  • 15
    • 79956352791 scopus 로고    scopus 로고
    • Hybrid controls combining first principle calculations with empirical modeling for fully automated fluid bed processing
    • under review
    • Zacour BM, Drennen JK, Anderson CA. Hybrid controls combining first principle calculations with empirical modeling for fully automated fluid bed processing. Journal of Pharmaceutical Innovation, 2011: under review.
    • (2011) Journal of Pharmaceutical Innovation
    • Zacour, B.M.1    Drennen, J.K.2    Anderson, C.A.3
  • 16
    • 79956357497 scopus 로고    scopus 로고
    • Efficient near infrared spectroscopic calibrations for pharmaceutical blend monitoring
    • doi: 10.1007/s12247-011-9096-4
    • Zacour MZ, Igne B, Drennen JK, Anderson CA. efficient near infrared spectroscopic calibrations for pharmaceutical blend monitoring. Journal of Pharmaceutical Innovation 2011;doi: 10.1007/s12247-011-9096-4
    • (2011) Journal of Pharmaceutical Innovation
    • Zacour, M.Z.1    Igne, B.2    Drennen, J.K.3    Anderson, C.A.4
  • 17
    • 0017551494 scopus 로고
    • Least-squares curve-fitting of Fourier transform infrared spectra with applications to polymer systems
    • MK Antoon JH Koenig JL Koenig 1977 Least-squares curve-fitting of Fourier transform infrared spectra with applications to polymer systems Appl Spectrosc 31 518 524 10.1366/000370277774464156 1:CAS:528:DyaE1cXivFyqtQ%3D%3D (Pubitemid 8559154)
    • (1977) Applied Spectroscopy , vol.31 , Issue.6 , pp. 518-524
    • Antoon, M.K.1    Koenig, J.H.2    Koenig, J.L.3
  • 18
    • 0019055543 scopus 로고
    • Improved sensitivity of infrared spectroscopy by the application of least squares methods
    • 10.1366/0003702804731258 1:CAS:528:DyaL3cXlslyqtbk%3D
    • DM Haaland RG Easterling 1980 Improved sensitivity of infrared spectroscopy by the application of least squares methods Appl Spectrosc 34 539 548 10.1366/0003702804731258 1:CAS:528:DyaL3cXlslyqtbk%3D
    • (1980) Appl Spectrosc , vol.34 , pp. 539-548
    • Haaland, D.M.1    Easterling, R.G.2
  • 19
    • 0000920105 scopus 로고
    • Multivariate instrument standardization
    • 10.1021/ac00023a016 1:CAS:528:DyaK3MXmsVKrsLo%3D
    • Y Wang DJ Veltkamp R Kowalski 1991 Multivariate instrument standardization Anal Chem 63 2750 2756 10.1021/ac00023a016 1:CAS:528: DyaK3MXmsVKrsLo%3D
    • (1991) Anal Chem , vol.63 , pp. 2750-2756
    • Wang, Y.1    Veltkamp, D.J.2    Kowalski, R.3
  • 20
    • 0000287955 scopus 로고    scopus 로고
    • Standardization of near-infrared spectroscopic instruments
    • 10.1021/ac9510595 1:CAS:528:DyaK28XpsFKiug%3D%3D
    • E Bouveresse C Hartmann DL Massart IR Last KA Prebble 1996 Standardization of near-infrared spectroscopic instruments Anal Chem 68 982 990 10.1021/ac9510595 1:CAS:528:DyaK28XpsFKiug%3D%3D
    • (1996) Anal Chem , vol.68 , pp. 982-990
    • Bouveresse, E.1    Hartmann, C.2    Massart, D.L.3    Last, I.R.4    Prebble, K.A.5
  • 21
    • 0024069289 scopus 로고
    • The effect of multiplicative scatter correction (MSC) and linearity improvement in NIR spectroscopy
    • 10.1366/0003702884429869
    • T Isaksson T Næs 1988 The effect of multiplicative scatter correction (MSC) and linearity improvement in NIR spectroscopy Appl Spectrosc 42 1177 1321 10.1366/0003702884429869
    • (1988) Appl Spectrosc , vol.42 , pp. 1177-1321
    • Isaksson, T.1    Næs, T.2
  • 22
    • 0024701578 scopus 로고
    • Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra
    • 10.1366/0003702894202201 1:CAS:528:DyaL1MXlt1aqsL4%3D
    • RJ Barnes MS Dhanoa SJ Lister 1989 Standard normal variate transformation and de-trending of near-infrared diffuse reflectance spectra Appl Spectrosc 43 772 776 10.1366/0003702894202201 1:CAS:528:DyaL1MXlt1aqsL4%3D
    • (1989) Appl Spectrosc , vol.43 , pp. 772-776
    • Barnes, R.J.1    Dhanoa, M.S.2    Lister, S.J.3
  • 23
    • 0032517819 scopus 로고    scopus 로고
    • Orthogonal signal correction of near-infrared spectra
    • DOI 10.1016/S0169-7439(98)00109-9, PII S0169743998001099
    • S Wold H Antti F Lindgren J Ohman 1998 Orthogonal signal correction of near-infrared spectra Chemom Intell Lab Syst 44 175 185 10.1016/S0169-7439(98) 00109-9 1:CAS:528:DyaK1cXnt1SqsbY%3D (Pubitemid 29016095)
    • (1998) Chemometrics and Intelligent Laboratory Systems , vol.44 , Issue.1-2 , pp. 175-185
    • Wold, S.1    Antti, H.2    Lindgren, F.3    Ohman, J.4
  • 24
    • 0033982350 scopus 로고    scopus 로고
    • On orthogonal signal correction
    • DOI 10.1016/S0169-7439(99)00045-3, PII S0169743999000453
    • T Fearn 2000 On orthogonal signal correction Chemom Intell Lab Syst 50 47 52 10.1016/S0169-7439(99)00045-3 1:CAS:528:DC%2BD3cXislyhtg%3D%3D (Pubitemid 30019318)
    • (2000) Chemometrics and Intelligent Laboratory Systems , vol.50 , Issue.1 , pp. 47-52
    • Fearn, T.1
  • 25
    • 2642575685 scopus 로고    scopus 로고
    • Transfer by orthogonal projection: Making near-infrared calibrations robust to between-instrument variation
    • DOI 10.1016/j.chemolab.2004.02.004, PII S0169743904000516
    • A Andrew T Fearn 2004 Transfer by orthogonal projection: making near-infrared calibrations robust to between-instrument variation Chemom Intell Lab Syst 72 51 56 10.1016/j.chemolab.2004.02.004 1:CAS:528:DC%2BD2cXks1Wiuro%3D (Pubitemid 38721400)
    • (2004) Chemometrics and Intelligent Laboratory Systems , vol.72 , Issue.1 , pp. 51-56
    • Andrew, A.1    Fearn, T.2
  • 26
    • 32944472427 scopus 로고    scopus 로고
    • Dynamic orthogonal projection. A new method to maintain the on-line robustness of multivariate calibrations. Application to NIR-based monitoring of wine fermentations
    • DOI 10.1016/j.chemolab.2005.06.011, PII S0169743905000997
    • M Zeaiter JM Roger V Bellon-Maurel 2006 Dynamic orthogonal projection. A new method to maintain the on-line robustness of multivariate calibrations. Application to NIR-based monitoring of wine fermentations Chemom Intell Lab Syst 80 227 235 10.1016/j.chemolab.2005.06.011 1:CAS:528:DC%2BD28XhslOrtbw%3D (Pubitemid 43259501)
    • (2006) Chemometrics and Intelligent Laboratory Systems , vol.80 , Issue.2 , pp. 227-235
    • Zeaiter, M.1    Roger, J.M.2    Bellon-Maurel, V.3
  • 27
    • 0038259241 scopus 로고    scopus 로고
    • Standardisation and calibration transfer for near infrared instruments: A review
    • T Fearn 2001 Standardization and calibration transfer for near infrared instruments: a review J Near Infrared Spectrosc 9 229 244 10.1255/jnirs.309 1:CAS:528:DC%2BD38XosFOrtg%3D%3D (Pubitemid 33688852)
    • (2001) Journal of Near Infrared Spectroscopy , vol.9 , Issue.4 , pp. 229-244
    • Fearn, T.1
  • 29
    • 0002845511 scopus 로고    scopus 로고
    • Standardisation of near-infrared spectrometric instruments: A review
    • DOI 10.1016/0924-2031(95)00055-0
    • E Bouveresse DL Massart 1996 Standardization of near-infrared spectrometric instruments: a review Vib Spectrosc 11 3 15 10.1016/0924-2031(95) 00055-0 1:CAS:528:DyaK28XhvVOjtrg%3D (Pubitemid 126404183)
    • (1996) Vibrational Spectroscopy , vol.11 , Issue.SPEC. ISS. , pp. 3-15
    • Bouveresse, E.1    Massart, D.L.2
  • 30
    • 70349989987 scopus 로고    scopus 로고
    • Improving the transfer of near infrared prediction models by orthogonal methods
    • 10.1016/j.chemolab.2009.07.007 1:CAS:528:DC%2BD1MXht1WmsL%2FJ
    • B Igne JM Roger S Roussel V Bellon-Maurel CR Hurburgh 2009 Improving the transfer of near infrared prediction models by orthogonal methods Chemom Intell Lab Syst 99 57 65 10.1016/j.chemolab.2009.07.007 1:CAS:528:DC%2BD1MXht1WmsL%2FJ
    • (2009) Chemom Intell Lab Syst , vol.99 , pp. 57-65
    • Igne, B.1    Roger, J.M.2    Roussel, S.3    Bellon-Maurel, V.4    Hurburgh, C.R.5
  • 31
    • 0037024738 scopus 로고    scopus 로고
    • New augmented classical least squares methods for improved quantitative spectral analyses
    • DOI 10.1016/S0924-2031(01)00199-0, PII S0924203101001990
    • DM Haaland DK Melgaard 2002 New augmented classical least squares methods for improved quantitative spectral analyses Vib Spectrosc 29 171 175 10.1016/S0924-2031(01)00199-0 1:CAS:528:DC%2BD38XkslOrtLc%3D (Pubitemid 34660623)
    • (2002) Vibrational Spectroscopy , vol.29 , Issue.1-2 , pp. 171-175
    • Haaland, D.M.1    Melgaard, D.K.2
  • 32
    • 0002363710 scopus 로고
    • A note on normal correlation
    • EJG Pitman 1939 A note on normal correlation Biometrika 31 9 12
    • (1939) Biometrika , vol.31 , pp. 9-12
    • Pitman, E.J.G.1
  • 33
    • 77049116775 scopus 로고    scopus 로고
    • Local chemometrics for samples and variables: Optimizing calibration and standardization processes
    • 1:CAS:528:DC%2BC3cXisValtrw%3D
    • B Igne CR Hurburgh 2010 Local chemometrics for samples and variables: optimizing calibration and standardization processes J Chemometr 24 75 86 1:CAS:528:DC%2BC3cXisValtrw%3D
    • (2010) J Chemometr , vol.24 , pp. 75-86
    • Igne, B.1    Hurburgh, C.R.2
  • 34
    • 31944439159 scopus 로고    scopus 로고
    • Evaluation of pretreatment strategies for near-infrared spectroscopy calibration development of unground and ground compound feedingstuffs
    • DOI 10.1366/000370206775382839
    • VM Fernandez-Cabanas A Garrido-Varo D Perez-Martin P Dardenne 2006 Evaluation of pretreatment strategies for near-infrared spectroscopy calibration development of unground and ground compound feedingstuffs Appl Spectrosc 60 17 23 16454905 10.1366/000370206775382839 1:CAS:528:DC%2BD28XosFaitg%3D%3D (Pubitemid 43188293)
    • (2006) Applied Spectroscopy , vol.60 , Issue.1 , pp. 17-23
    • Fernandez-Cabanas, V.M.1    Garrido-Varo, A.2    Perez-Marin, D.3    Dardenne, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.