Volumn 25, Issue 11, 2011, Pages 1683-1685

Long-term performance of the Gasbench isotope ratio mass spectrometry system for the stable isotope analysis of carbonate microsamples

Author keywords

[No Author keywords available]

Indexed keywords

MASS SPECTROMETRY;

EID: 79956307109     PISSN: 09514198     EISSN: 10970231     Source Type: Journal    
DOI: 10.1002/rcm.5037     Document Type: Letter
Times cited : (67)

References (11)
  • 1
    • 0001175714 scopus 로고
    • On the isotopic chemistry of carbonates and a paleotemperature scale
    • J. M. McCrea,. On the isotopic chemistry of carbonates and a paleotemperature scale. J. Chem. Phys. 1950, 18, 849.
    • (1950) J. Chem. Phys. , vol.18 , pp. 849
    • McCrea, J.M.1
  • 2
    • 0038035651 scopus 로고    scopus 로고
    • Continuous-flow isotope ratio mass spectrometric analysis of carbonate minerals
    • C. Spötl, T. W. Vennemann,. Continuous-flow isotope ratio mass spectrometric analysis of carbonate minerals. Rapid Commun. Mass Spectrom. 2002, 17, 1004.
    • (2002) Rapid Commun. Mass Spectrom. , vol.17 , pp. 1004
    • Spötl, C.1    Vennemann, T.W.2
  • 3
    • 23844487067 scopus 로고    scopus 로고
    • High-precision oxygen and carbon isotope analysis of very small (10-30 μg) amounts of carbonates using continuous flow isotope ratio mass spectrometry
    • J. Fiebig, B. Schöne, W. Oschmann,. High-precision oxygen and carbon isotope analysis of very small (10-30 μg) amounts of carbonates using continuous flow isotope ratio mass spectrometry. Rapid Commun. Mass Spectrom. 2005, 19, 2355.
    • (2005) Rapid Commun. Mass Spectrom. , vol.19 , pp. 2355
    • Fiebig, J.1    Schöne, B.2    Oschmann, W.3
  • 4
    • 33947303192 scopus 로고    scopus 로고
    • Assessment of carbonate-phosphoric acid analytical technique performed using GasBench II in continuous flow isotope ratio mass spectrometry
    • D. Paul, G. Skrzypek,. Assessment of carbonate-phosphoric acid analytical technique performed using GasBench II in continuous flow isotope ratio mass spectrometry. Int. J. Mass Spectrom. 2007, 262, 180.
    • (2007) Int. J. Mass Spectrom. , vol.262 , pp. 180
    • Paul, D.1    Skrzypek, G.2
  • 5
    • 33745776104 scopus 로고    scopus 로고
    • Flushing time and storage effects on the accuracy and precision of cabon and oxygen isotope ratios of sample using the Gasbench II technique
    • D. Paul, G. Skrzypek,. Flushing time and storage effects on the accuracy and precision of cabon and oxygen isotope ratios of sample using the Gasbench II technique. Rapid Commun. Mass Spectrom. 2006, 20, 2033.
    • (2006) Rapid Commun. Mass Spectrom. , vol.20 , pp. 2033
    • Paul, D.1    Skrzypek, G.2
  • 6
    • 2542574164 scopus 로고    scopus 로고
    • A simple method of soil gas stable carbon isotope analysis
    • C. Spötl,. A simple method of soil gas stable carbon isotope analysis. Rapid Commun. Mass Spectrom. 2004, 18, 1239.
    • (2004) Rapid Commun. Mass Spectrom. , vol.18 , pp. 1239
    • Spötl, C.1
  • 8
    • 0036427214 scopus 로고    scopus 로고
    • 3 measured by continuous flow isotope ratio mass spectrometry: Statistical evaluation and verification by application to Devils Hole core DH-11 calcite
    • 3 measured by continuous flow isotope ratio mass spectrometry: statistical evaluation and verification by application to Devils Hole core DH-11 calcite. Rapid Commun. Mass Spectrom. 2002, 16, 2102.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 2102
    • Revesz, K.M.1    Landwehr, J.M.2
  • 9
    • 0022417184 scopus 로고
    • Exchange of oxygen isotopes in carbon-dioxide-phosphoric acid systems
    • E. A. Wachter, J. M. Hayes,. Exchange of oxygen isotopes in carbon-dioxide-phosphoric acid systems. Chem. Geol. (Isotope Geosci. Sect.) 1985, 52, 365.
    • (1985) Chem. Geol. (Isotope Geosci. Sect.) , vol.52 , pp. 365
    • Wachter, E.A.1    Hayes, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.