-
1
-
-
0033805274
-
Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis
-
Haigis W, Lege B, Miller N, et al. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graef Arch Clin Exp. 2000;238:765-773.
-
(2000)
Graef Arch Clin Exp.
, vol.238
, pp. 765-773
-
-
Haigis, W.1
Lege, B.2
Miller, N.3
-
2
-
-
0027442385
-
The Hoffer Q formula: A comparison of theoretic and regression formulas
-
Hoffer K. The Hoffer Q formula: A comparison of theoretic and regression formulas. J Cataract Refract Surg. 1993;19:701.
-
(1993)
J Cataract Refract Surg.
, vol.19
, pp. 701
-
-
Hoffer, K.1
-
3
-
-
0023870818
-
A three-part system for refining intraocular lens power calculations
-
Holladay J, Prager T, Chandler T, et al. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14:17.
-
(1988)
J Cataract Refract Surg.
, vol.14
, pp. 17
-
-
Holladay, J.1
Prager, T.2
Chandler, T.3
-
4
-
-
0025315983
-
Development of the SRK/T intraocular lens implant power calculation formula
-
Retzlaff J, Sanders D, Kraff M. Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg. 1990;16:333.
-
(1990)
J Cataract Refract Surg.
, vol.16
, pp. 333
-
-
Retzlaff, J.1
Sanders, D.2
Kraff, M.3
-
5
-
-
0036688211
-
Ray tracing for intraocular lens calculation
-
DOI 10.1016/S0886-3350(01)01346-3, PII S0886335001013463
-
Preussner P, Wahl J, Lahdo H, et al. Ray tracing for intraocular lens calculation. J Cataract Refract Surg. 2002;28:1412-1419. (Pubitemid 37022452)
-
(2002)
Journal of Cataract and Refractive Surgery
, vol.28
, Issue.8
, pp. 1412-1419
-
-
Preussner, P.-R.1
Wahl, J.2
Lahdo, H.3
Dick, B.4
Findl, O.5
-
8
-
-
0347379977
-
Intraocular lens power calculation after corneal refractive surgery: Double-K method
-
DOI 10.1016/S0886-3350(03)00957-X
-
Aramberri J. Intraocular lens power calculation after corneal refractive surgery: Double-K method. J Cataract Refract Surg. 2003;29:2063-2068. (Pubitemid 37548747)
-
(2003)
Journal of Cataract and Refractive Surgery
, vol.29
, Issue.11
, pp. 2063-2068
-
-
Aramberri, J.1
-
9
-
-
0042828973
-
Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis
-
DOI 10.1016/S0002-9394(03)00275-7
-
Shammas H, Shammas M, Garabet A, et al. Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. Am J Ophthalmol. 2003;136:426-432 (Pubitemid 37101238)
-
(2003)
American Journal of Ophthalmology
, vol.136
, Issue.3
, pp. 426-432
-
-
Shammas, H.J.1
Shammas, M.C.2
Garabet, A.3
Kim, J.H.4
Shammas, A.5
Labree, L.6
-
10
-
-
33646073049
-
Accurate intraocular lens power calculation after myopic laser in situ keratomileusis, bypassing corneal power
-
Walter K, Gagnon M, Hoopes P. Accurate intraocular lens power calculation after myopic laser in situ keratomileusis, bypassing corneal power. J Cataract Refract Surg. 2006;32:425-429.
-
(2006)
J Cataract Refract Surg.
, vol.32
, pp. 425-429
-
-
Walter, K.1
Gagnon, M.2
Hoopes, P.3
-
11
-
-
0035434886
-
Monochromatic aberrations of the human eye in a large population
-
Porter J, Guirao A, Cox I, et al. Monochromatic aberrations of the human eye in a large population. J Opt Soc Am A. 2001;18:1793-1803.
-
(2001)
J Opt Soc Am A.
, vol.18
, pp. 1793-1803
-
-
Porter, J.1
Guirao, A.2
Cox, I.3
-
12
-
-
0034899732
-
Real-time optical coherence tomography of the anterior segment at 1310 nm
-
Radhakrishnan S, Rollins A, Roth J, et al. Real-time optical coherence tomography of the anterior segment at 1310 nm. Arch Ophthalmol. 2001;119:1179.
-
(2001)
Arch Ophthalmol.
, vol.119
, pp. 1179
-
-
Radhakrishnan, S.1
Rollins, A.2
Roth, J.3
-
13
-
-
85080323745
-
Iteratively re-weighted bicubic spline representation of corneal topography and its comparison to the standard methods
-
DOI: 10.1016/j.zemedi.2010.1007.1002
-
Zhu Z, Janunts E, Eppig T, et al. Iteratively re-weighted bicubic spline representation of corneal topography and its comparison to the standard methods. Z Med Phys. 2010; DOI: 10.1016/j.zemedi.2010.1007.1002.
-
(2010)
Z Med Phys.
-
-
Zhu, Z.1
Janunts, E.2
Eppig, T.3
-
15
-
-
44649162716
-
Binocular lens tilt and decentration measurements in healthy subjects with phakic eyes
-
Schaeffel F. Binocular lens tilt and decentration measurements in healthy subjects with phakic eyes. Invest Ophth Vis Sci. 2008;49:2216.
-
(2008)
Invest Ophth Vis Sci.
, vol.49
, pp. 2216
-
-
Schaeffel, F.1
-
16
-
-
84950609221
-
The mean shape of the human cornea
-
Kiely P, Smith G, Carney L. The mean shape of the human cornea. J Mod Opt. 1982;29:1027-1040.
-
(1982)
J Mod Opt.
, vol.29
, pp. 1027-1040
-
-
Kiely, P.1
Smith, G.2
Carney, L.3
-
18
-
-
67249092156
-
Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye
-
Eppig T, Scholz K, Loffler A, et al. Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye. J Cataract Refract Surg. 2009;35:1091-1100.
-
(2009)
J Cataract Refract Surg.
, vol.35
, pp. 1091-1100
-
-
Eppig, T.1
Scholz, K.2
Loffler, A.3
|