메뉴 건너뛰기




Volumn 10, Issue 5, 2011, Pages 1119-1125

An integrated silicon sensor with microfluidic chip for monitoring potassium and pH

Author keywords

ChemFET; Computational fluid dynamics; ISFET; Microfluidic

Indexed keywords

ANALYTES; BIOLOGICAL FLUIDS; CHEMFET; CHEMICAL SPECIES; DEVICE RESPONSE; DIFFUSION COEFFICIENTS; DIFFUSIVE TRANSPORT; EXPERIMENTAL MEASUREMENTS; FIELD EFFECTS; ISFET; MEAN FLOW; MICROFLUIDIC CHIP; NUMERICAL STUDIES; PASSIVE DIFFUSIONS; RESPONSE TIME;

EID: 79956144040     PISSN: 16134982     EISSN: 16134990     Source Type: Journal    
DOI: 10.1007/s10404-010-0740-y     Document Type: Article
Times cited : (16)

References (15)
  • 1
    • 0037096670 scopus 로고    scopus 로고
    • Micro total analysis systems. 2. Analytical standard operations and applications
    • DOI 10.1021/ac020239t
    • PA Auroux D Iossifidis DR Reyes A Manz 2002 Micro total analysis systems. 2. Analytical standard operations and applications Anal Chem 74 12 2637 2652 10.1021/Ac020239t 10.1021/ac020239t (Pubitemid 34651166)
    • (2002) Analytical Chemistry , vol.74 , Issue.12 , pp. 2637-2652
    • Auroux, P.-A.1    Iossifidis, D.2    Reyes, D.R.3    Manz, A.4
  • 2
    • 0015388173 scopus 로고
    • Development, operation, and application of the ion-sensitive field-effect transistor as a tool for electrophysiology
    • 10.1109/TBME.1972.324137
    • P Bergveld 1972 Development, operation, and application of the ion-sensitive field-effect transistor as a tool for electrophysiology IEEE Trans Biomed Eng 19 5 342 351 10.1109/TBME.1972.324137
    • (1972) IEEE Trans Biomed Eng , vol.19 , Issue.5 , pp. 342-351
    • Bergveld, P.1
  • 3
    • 0037211184 scopus 로고    scopus 로고
    • Thirty years of ISFETOLOGY: What happened in the past 30 years and what may happen in the next 30 years
    • DOI 10.1016/S0925-4005(02)00301-5, PII S0925400502003015
    • P Bergveld 2003 Thirty years of isfetology-what happened in the past 30 years and what may happen in the next 30 years Sens Actuator B 88 1 1 20 10.1016/S0925-4005(02)00301-5 (Pubitemid 35412494)
    • (2003) Sensors and Actuators, B: Chemical , vol.88 , Issue.1 , pp. 1-20
    • Bergveld, P.1
  • 4
    • 0035974991 scopus 로고    scopus 로고
    • Multi-ion analysis based on versatile sensor head
    • DOI 10.1016/S0925-4005(01)00833-4, PII S0925400501008334
    • M Chudy W Wróblewski A Dybko Z Brzózka 2001 Multi-ion analysis based on versatile sensor head Sens Actuators B 78 1-3 320 325 10.1016/S0925-4005(01)00833-4 (Pubitemid 32746235)
    • (2001) Sensors and Actuators, B: Chemical , vol.78 , Issue.1-3 , pp. 320-325
    • Chudy, M.1    Wroblewski, W.2    Dybko, A.3    Brzozka, Z.4
  • 5
    • 0032403465 scopus 로고    scopus 로고
    • Rapid prototyping of microfluidic systems in poly(dimethylsiloxane)
    • DOI 10.1021/ac980656z
    • DC Duffy JC McDonald OJA Schueller GM Whitesides 1998 Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) Anal Chem 70 23 4974 4984 10.1021/ac980656z (Pubitemid 28553167)
    • (1998) Analytical Chemistry , vol.70 , Issue.23 , pp. 4974-4984
    • Duffy, D.C.1    McDonald, J.C.2    Schueller, O.J.A.3    Whitesides, G.M.4
  • 6
    • 23644434281 scopus 로고    scopus 로고
    • Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes
    • DOI 10.1039/b504551g
    • O Hofmann 2005 Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes Lab Chip 5 8 863 868 10.1039/b504551g (Pubitemid 41117314)
    • (2005) Lab on a Chip - Miniaturisation for Chemistry and Biology , vol.5 , Issue.8 , pp. 863-868
    • Hofmann, O.1    Wang, X.2    DeMello, J.C.3    Bradley, D.D.C.4    DeMello, A.J.5
  • 7
    • 79956067343 scopus 로고    scopus 로고
    • Time-resolved charge transport sensing by chemoreceptive neuron mos transistors (cvmos) with microfluidic channels
    • 10.1109/JSEN.2007.904893
    • BC Jacquot C Lee YN Shen EC Kan 2007 Time-resolved charge transport sensing by chemoreceptive neuron mos transistors (cvmos) with microfluidic channels IEEE Sens J 7 9-10 1429 1434 10.1109/JSEN.2007.904893
    • (2007) IEEE Sens J , vol.7 , Issue.910 , pp. 1429-1434
    • Jacquot, B.C.1    Lee, C.2    Shen, Y.N.3    Kan, E.C.4
  • 8
    • 33845334533 scopus 로고    scopus 로고
    • Low-power concentration and separation using temperature gradient focusing via Joule heating
    • DOI 10.1021/ac061194p
    • SM Kim GJ Sommer MA Burns EF Hasselbrink 2006 Low-power concentration and separation using temperature gradient focusing via joule heating Anal Chem 78 23 8028 8035 10.1021/ac061194p (Pubitemid 44871768)
    • (2006) Analytical Chemistry , vol.78 , Issue.23 , pp. 8028-8035
    • Sun, M.K.1    Sommer, G.J.2    Burns, M.A.3    Hasselbrink, E.F.4
  • 9
    • 33747108498 scopus 로고    scopus 로고
    • Microfluidic polymer chip integrated with an ISFET detector for cationic surfactant assay in dental rinses
    • 10.2116/analsci.22.1065
    • T Masadome K Yada SI Wakida 2006 Microfluidic polymer chip integrated with an ISFET detector for cationic surfactant assay in dental rinses Anal Sci 22 8 1065 1069 10.2116/analsci.22.1065
    • (2006) Anal Sci , vol.22 , Issue.8 , pp. 1065-1069
    • Masadome, T.1    Yada, K.2    Wakida, S.I.3
  • 10
    • 25144464152 scopus 로고    scopus 로고
    • A large transistor-based sensor array chip for direct extracellular imaging
    • DOI 10.1016/j.snb.2005.01.020, PII S0925400505001103
    • MJ Milgrew MO Riehle DRS Cumming 2005 A large transistor-based sensor array chip for direct extracellular imaging Sens Actuator B 111 347 353 10.1016/j.snb.2005.01.020 (Pubitemid 41354886)
    • (2005) Sensors and Actuators, B: Chemical , vol.111-112 , Issue.SUPPL. , pp. 347-353
    • Milgrew, M.J.1    Riehle, M.O.2    Cumming, D.R.S.3
  • 11
    • 0037096666 scopus 로고    scopus 로고
    • Micro total analysis systems. 1. Introduction, theory, and technology
    • DOI 10.1021/ac0202435
    • DR Reyes D Iossifidis PA Auroux A Manz 2002 Micro total analysis systems. 1. Introduction, theory, and technology Anal Chem 74 12 2623 2636 10.1021/Ac0202435 10.1021/ac0202435 (Pubitemid 34651165)
    • (2002) Analytical Chemistry , vol.74 , Issue.12 , pp. 2623-2636
    • Reyes, D.R.1    Iossifidis, D.2    Auroux, P.-A.3    Manz, A.4
  • 12
    • 0033615480 scopus 로고    scopus 로고
    • Field-effect flow control for microfabricated fluidic networks
    • 10.1126/science.286.5441.942
    • RBM Schasfoort S Schlautmann L Hendrikse A van den Berg 1999 Field-effect flow control for microfabricated fluidic networks Science 286 5441 942 945 10.1126/science.286.5441.942
    • (1999) Science , vol.286 , Issue.5441 , pp. 942-945
    • Schasfoort, R.B.M.1    Schlautmann, S.2    Hendrikse, L.3    Van Den Berg, A.4
  • 13
    • 0036742450 scopus 로고    scopus 로고
    • Recent advances in biologically sensitive field-effect transistors (biofets)
    • 10.1039/b204444g
    • M Schning 2002 Recent advances in biologically sensitive field-effect transistors (biofets) Analyst 127 9 1137 1151 10.1039/b204444g
    • (2002) Analyst , vol.127 , Issue.9 , pp. 1137-1151
    • Schning, M.1
  • 14
    • 33645765567 scopus 로고    scopus 로고
    • Silicon-on-insulator microfluidic device with monolithic sensor integration for Mu-TAS applications
    • 10.1109/JMEMS.2006.872222
    • S Sharma K Buchholz SM Luber U Rant M Tornow G Abstreiter 2006 Silicon-on-insulator microfluidic device with monolithic sensor integration for Mu-TAS applications J Microelectromech Syst 15 2 308 313 10.1109/JMEMS.2006. 872222
    • (2006) J Microelectromech Syst , vol.15 , Issue.2 , pp. 308-313
    • Sharma, S.1    Buchholz, K.2    Luber, S.M.3    Rant, U.4    Tornow, M.5    Abstreiter, G.6
  • 15
    • 33747873523 scopus 로고    scopus 로고
    • Monitoring liquid transport and chemical composition in lab on a chip systems using ion sensitive FET devices
    • DOI 10.1039/b604815c
    • P Truman P Uhlmann M Stamm 2006 Monitoring liquid transport and chemical composition in lab on a chip systems using ion sensitive FET devices Lab Chip 6 9 1220 1228 10.1039/b604815c (Pubitemid 44290154)
    • (2006) Lab on a Chip - Miniaturisation for Chemistry and Biology , vol.6 , Issue.9 , pp. 1220-1228
    • Truman, P.1    Uhlmann, P.2    Stamm, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.