메뉴 건너뛰기




Volumn 107, Issue 11, 2011, Pages 1698-1701

Efficacy and safety of transient ulnar artery compression to recanalize acute radial artery occlusion after transradial catheterization

Author keywords

[No Author keywords available]

Indexed keywords

ACETYLSALICYLIC ACID; HEPARIN;

EID: 79956103195     PISSN: 00029149     EISSN: 18791913     Source Type: Journal    
DOI: 10.1016/j.amjcard.2011.01.056     Document Type: Article
Times cited : (130)

References (15)
  • 1
    • 0033556298 scopus 로고    scopus 로고
    • Ultrasonic assessment of vascular complications in coronary angiography and angioplasty after transradial approach
    • DOI 10.1016/S0002-9149(98)00821-2, PII S0002914998008212
    • S. Nagai, S. Abe, T. Sato, K. Hozawa, K. Yuki, K. Hanashima, and H. Tomoike Ultrasonic assessment of vascular complications in coronary angiography and angioplasty after transradial approach Am J Cardiol 83 1999 180 186 (Pubitemid 29047296)
    • (1999) American Journal of Cardiology , vol.83 , Issue.2 , pp. 180-186
    • Nagai, S.1    Abe, S.2    Sato, T.3    Hozawa, K.4    Yuki, K.5    Hanashima, K.6    Tomoike, H.7
  • 6
    • 53849138800 scopus 로고    scopus 로고
    • Prevention of radial artery occlusion-patent hemostasis evaluation trial (PROPHET study): A randomized comparison of traditional versus patency documented hemostasis after transradial catheterization
    • S. Pancholy, J. Coppola, T. Patel, and M. Roke-Thomas Prevention of radial artery occlusion-patent hemostasis evaluation trial (PROPHET study): a randomized comparison of traditional versus patency documented hemostasis after transradial catheterization Catheter Cardiovasc Interv 72 2008 335 340
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 335-340
    • Pancholy, S.1    Coppola, J.2    Patel, T.3    Roke-Thomas, M.4
  • 7
    • 2342429309 scopus 로고    scopus 로고
    • Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: Comparison with the Allen's test in 1010 patients
    • DOI 10.1016/j.ahj.2003.10.038, PII S000287030300783X
    • G.R. Barbeau, F. Arsenault, L. Dugas, S. Simard, and M.M. Lariviere Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: comparison with the Allen's test in 1010 patients Am Heart J 147 2004 489 493 (Pubitemid 38880871)
    • (2004) American Heart Journal , vol.147 , Issue.3 , pp. 489-493
    • Barbeau, G.R.1    Arsenault, F.2    Dugas, L.3    Simard, S.4    Lariviere, M.M.5
  • 9
    • 37649020896 scopus 로고    scopus 로고
    • Transradial access in an occluded radial artery: New technique
    • S.B. Pancholy Transradial access in an occluded radial artery: new technique J Invasive Cardiol 19 2007 541 544
    • (2007) J Invasive Cardiol , vol.19 , pp. 541-544
    • Pancholy, S.B.1
  • 10
    • 77957727063 scopus 로고    scopus 로고
    • Anterograde recanalisation of the radial artery followed by transradial angioplasty
    • Z. Ruzsa, L. Pinter, and R. Kolvenbach Anterograde recanalisation of the radial artery followed by transradial angioplasty Cardiovasc Revasc Med 11 2010 e1 e4
    • (2010) Cardiovasc Revasc Med , vol.11
    • Ruzsa, Z.1    Pinter, L.2    Kolvenbach, R.3
  • 11
    • 79952215408 scopus 로고    scopus 로고
    • Recanalization and reuse of early occluded radial artery within 6 days after previous transradial diagnostic procedure
    • A. Babunashvili, and D. Dundua Recanalization and reuse of early occluded radial artery within 6 days after previous transradial diagnostic procedure Catheter Cardiovasc Interv 77 2011 530 536
    • (2011) Catheter Cardiovasc Interv , vol.77 , pp. 530-536
    • Babunashvili, A.1    Dundua, D.2
  • 12
    • 0032929347 scopus 로고    scopus 로고
    • Influence of the ratio between radial artery inner diameter and sheath outer diameter on radial artery flow after transradial coronary intervention
    • S. Saito, H. Ikei, G. Hosokawa, and S. Tanaka Influence of the ratio between radial artery inner diameter and sheath outer diameter on radial artery flow after transradial coronary intervention Catheter Cardiovasc Interv 46 1999 173 178 (Pubitemid 29066623)
    • (1999) Catheterization and Cardiovascular Diagnosis , vol.46 , Issue.2 , pp. 173-178
    • Saito, S.1    Ikei, H.2    Hosokawa, G.3    Tanaka, S.4
  • 13
    • 70349510066 scopus 로고    scopus 로고
    • Comparison of the effect of intra-arterial versus intravenous heparin on radial artery occlusion after transradial catheterization
    • S.B. Pancholy Comparison of the effect of intra-arterial versus intravenous heparin on radial artery occlusion after transradial catheterization Am J Cardiol 104 2009 1083 1085
    • (2009) Am J Cardiol , vol.104 , pp. 1083-1085
    • Pancholy, S.B.1
  • 14
    • 77956014334 scopus 로고    scopus 로고
    • Impact of length and hydrophilic coating of the introducer sheath on radial artery spasm during transradial coronary intervention: A randomized study
    • S. Rathore, R.H. Stables, M. Pauriah, A. Hakeem, J.D. Mills, N.D. Palmer, R.A. Perry, and J.L. Morris Impact of length and hydrophilic coating of the introducer sheath on radial artery spasm during transradial coronary intervention: a randomized study J Am Coll Cardiol Interv 3 2010 475 483
    • (2010) J Am Coll Cardiol Interv , vol.3 , pp. 475-483
    • Rathore, S.1    Stables, R.H.2    Pauriah, M.3    Hakeem, A.4    Mills, J.D.5    Palmer, N.D.6    Perry, R.A.7    Morris, J.L.8
  • 15
    • 78649661560 scopus 로고    scopus 로고
    • Radial artery thrombosis following transradial coronary angiography: Incidence and rationale for treatment of symptomatic patients with low-molecular-weight heparins
    • A.R. Zankl, M. Andrassy, C. Volz, B. Ivandic, U. Krumsdorf, H.A. Katus, and E. Blessing Radial artery thrombosis following transradial coronary angiography: incidence and rationale for treatment of symptomatic patients with low-molecular-weight heparins Clin Res Cardiol 99 2010 841 847
    • (2010) Clin Res Cardiol , vol.99 , pp. 841-847
    • Zankl, A.R.1    Andrassy, M.2    Volz, C.3    Ivandic, B.4    Krumsdorf, U.5    Katus, H.A.6    Blessing, E.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.