-
1
-
-
36448969381
-
Accuracy of bedside capillary blood glucose measurements in critically ill patients
-
DOI 10.1007/s00134-007-0835-4
-
Critchell CD, Savarese V, Callahan A, Aboud C, Jabbour S, Marik P. Accuracy of bedside capillary blood glucose measurements in critically ill patients. Intensive Care Med 2007;33:2079-84. (Pubitemid 350164561)
-
(2007)
Intensive Care Medicine
, vol.33
, Issue.12
, pp. 2079-2084
-
-
Critchell, C.D.1
Savarese, V.2
Callahan, A.3
Aboud, C.4
Jabbour, S.5
Marik, P.6
-
2
-
-
50049124154
-
Comparison of POCT and central laboratory blood glucose results using arterial, capillary, and venous samples from MICU patients on a tight glycemic protocol
-
Petersen JR. Comparison of POCT and central laboratory blood glucose results using arterial, capillary, and venous samples from MICU patients on a tight glycemic protocol. Clin Chim Acta 2008;396:10-3.
-
(2008)
Clin Chim Acta
, vol.396
, pp. 10-13
-
-
Petersen, J.R.1
-
3
-
-
34249722646
-
Reliability of the measurement of glucose at the bedside of critical patients
-
Rivera S. Reliability of the measurement of glucose at the bedside of critical patients. Enferm Intensiva 2007;18:15-24.
-
(2007)
Enferm Intensiva
, vol.18
, pp. 15-24
-
-
Rivera, S.1
-
4
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
PII S0140673686908378
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10. (Pubitemid 16134762)
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
5
-
-
43549115256
-
Accuracy of glycemic measurements in the critically ill
-
DOI 10.1089/dia.2008.0263
-
Slater-MacLean L, Cembrowski G, Chin D, Shalapay C, Binette T, Hegadoren K, et al. Accuracy of glycemic measurements in the critically ill. Diab Technol Ther 2008;10:169-77. (Pubitemid 351677597)
-
(2008)
Diabetes Technology and Therapeutics
, vol.10
, Issue.3
, pp. 169-177
-
-
Slater-MacLean, L.1
Cembrowski, G.2
Chin, D.3
Shalapay, C.4
Binette, T.5
Hegadoren, K.6
Newburn-Cook, C.7
-
6
-
-
0029196039
-
Accuracy of fingerstick glucose values in shock patients
-
Sylvain HF, Pokorny ME, English SM, Benson NH, Whitley TW, Ferenczy CJ, et al. Accuracy of fingerstick glucose values in shock patients. Am J Crit Care 1995;4:44-8.
-
(1995)
Am J Crit Care
, vol.4
, pp. 44-48
-
-
Sylvain, H.F.1
Pokorny, M.E.2
English, S.M.3
Benson, N.H.4
Whitley, T.W.5
Ferenczy, C.J.6
-
7
-
-
0026425184
-
Fingerstick glucose determination in shock
-
Atkin SH, Dasmahapatra A, Jaker MA, Chorost MI, Reddy S. Fingerstick glucose determination in shock. Ann Intern Med 1991;114:1020-4.
-
(1991)
Ann Intern Med
, vol.114
, pp. 1020-1024
-
-
Atkin, S.H.1
Dasmahapatra, A.2
Jaker, M.A.3
Chorost, M.I.4
Reddy, S.5
-
8
-
-
48949100850
-
Pseudohypoglycemia: A cause for unreliable finger-stick glucose measurements
-
El Khoury M, Yousuf F, Martin V, Cohen RM. Pseudohypoglycemia: a cause for unreliable finger-stick glucose measurements. Endocr Pract 2008;14:337-9.
-
(2008)
Endocr Pract
, vol.14
, pp. 337-339
-
-
El Khoury, M.1
Yousuf, F.2
Martin, V.3
Cohen, R.M.4
-
9
-
-
42149100490
-
Accuracy of bedside glucometry in critically ill patients: Influence of clinical characteristics and perfusion index
-
DOI 10.4065/83.4.400
-
Desachy A, Vuagnat AC, Ghazali AD, Baudin OT, Longuet OH, Calvat SN, et al. Accuracy of bedside glucometry in critically ill patients: influence of clinical characteristics and perfusion index. Mayo Clin Proc 2008;83:400-5. (Pubitemid 351536465)
-
(2008)
Mayo Clinic Proceedings
, vol.83
, Issue.4
, pp. 400-405
-
-
Desachy, A.1
Vuagnat, A.C.2
Ghazali, A.D.3
Baudin, O.T.4
Longuet, O.H.5
Calvat, S.N.6
Gissot, V.7
-
10
-
-
0034128795
-
Effects of pH on glucose measurements with handheld glucose meters and a portable glucose analyzer for point-of-care testing
-
Tang Z, Du X, Louie RF, Kost GJ. Effects of pH on glucose measurements with handheld glucose meters and a portable glucose analyzer for point-of-care testing. Arch Pathol Lab Med 2000;124:577-82. (Pubitemid 30210991)
-
(2000)
Archives of Pathology and Laboratory Medicine
, vol.124
, Issue.4
, pp. 577-582
-
-
Tang, Z.1
Du, X.2
Louie, R.F.3
Kost, G.J.4
|