메뉴 건너뛰기




Volumn 37, Issue 1, 2011, Pages

Fever detection in under 5 children in a tertiary health facility using the infrared tympanic thermometer in the oral mode

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BODY TEMPERATURE MEASUREMENT; CHILD; CORE TEMPERATURE; FEMALE; FEVER; HUMAN; INFANT; INFRARED TYMPANIC THERMOMETER; MAJOR CLINICAL STUDY; MALE; MOUTH TEMPERATURE; PRESCHOOL CHILD; RECTUM TEMPERATURE; TERTIARY HEALTH CARE; TYMPANIC TEMPERATURE; TYMPANIC THERMOMETER; BODY TEMPERATURE; COMPARATIVE STUDY; EARDRUM; EQUIPMENT DESIGN; HEALTH CARE FACILITY; INFRARED RADIATION; MOUTH; NEWBORN; PATHOPHYSIOLOGY; SENSITIVITY AND SPECIFICITY; THERMOMETER;

EID: 79955951246     PISSN: 17208424     EISSN: 18247288     Source Type: Journal    
DOI: 10.1186/1824-7288-37-8     Document Type: Article
Times cited : (23)

References (23)
  • 1
    • 0026478011 scopus 로고
    • An appraisal of temperature assessment by infrared emission detection tympanic thermometry
    • 10.1016/S0196-0644(05)80067-8 1343571
    • An appraisal of temperature assessment by infrared emission detection tympanic thermometry. Terndrup TE, Ann Emerg Med 1992 21 1483 92 10.1016/S0196-0644(05)80067-8 1343571
    • (1992) Ann Emerg Med , vol.21 , pp. 1483-1492
    • Terndrup, T.E.1
  • 2
    • 0031709718 scopus 로고    scopus 로고
    • Comparison of esophageal, rectal, axillary, bladder, tympanic, and pulmonary artery temperatures in children
    • DOI 10.1016/S0022-3476(98)70067-8
    • Comparison of oesophageal, rectal, axillary, bladder, tympanic and pulmonary artery temperatures in children. Robinson JL, Seal RF, Spady DW, Joffres MR, J Pediatr 1998 133 553 6 10.1016/S0022-3476(98)70067-8 9787697 (Pubitemid 28465385)
    • (1998) Journal of Pediatrics , vol.133 , Issue.4 , pp. 553-556
    • Robinson, J.L.1    Seal, R.F.2    Spady, D.W.3    Joffres, M.R.4
  • 3
    • 0030842097 scopus 로고    scopus 로고
    • Estimation of contact tympanic membrane temperature with a noncontact infrared thermometer
    • DOI 10.1016/S0196-0644(97)70138-0
    • Estimation of Contact tympanic membrane temperature with a non contact infrared thermometer. Terndrup TE, Crofton DJ, Morelliti AJ, Kelley R, Rajk J, Ann Emerg Med 1997 30 171 5 10.1016/S0196-0644(97)70138-0 9250641 (Pubitemid 27334901)
    • (1997) Annals of Emergency Medicine , vol.30 , Issue.2 , pp. 171-175
    • Terndrup, T.E.1    Crofton, D.J.2    Mortelliti, A.J.3    Kelley, R.4    Rajk, J.5
  • 4
    • 0027318956 scopus 로고
    • The accuracy of infrared auditory canal thermometry in infants and children
    • The accuracy of infrared auditory canal thermometry in infants and children. Schuman AJ, Clin Pediatr 1993 32 347 54 10.1177/000992289303200605 (Pubitemid 23182139)
    • (1993) Clinical Pediatrics , vol.32 , Issue.6 , pp. 347-354
    • Schuman, A.J.1
  • 5
    • 18844480057 scopus 로고    scopus 로고
    • Comparative study of tympanic and mercury thermometry in children(abstract)
    • 9658694
    • Comparative study of tympanic and mercury thermometry in children(abstract). Montoya-Cabrera MA, Escalante-Galindo P, Flores-Alvarez E, Gac Med Mex 1998 134 9 14 9658694
    • (1998) Gac Med Mex , vol.134 , pp. 9-14
    • Montoya-Cabrera, M.A.1    Escalante-Galindo, P.2    Flores-Alvarez, E.3
  • 6
    • 0029339592 scopus 로고
    • A comparison of five methods of temperature measurement in febrile intensive care patients
    • 7663592
    • A comparison of five methods of temperature measurement in febrile intensive care patients. Schmitz T, Blair N, Falk M, Levine C, Am J Crit Care 1995 4 286 92 7663592
    • (1995) Am J Crit Care , vol.4 , pp. 286-292
    • Schmitz, T.1    Blair, N.2    Falk, M.3    Levine, C.4
  • 7
    • 33645682143 scopus 로고    scopus 로고
    • Thermometry in paediatric practice
    • 10.1136/adc.2005.088831 16551792
    • Thermometry in paediatric practice. El-Radhi AS, Barry W, Arch Dis Child 2006 91 351 6 10.1136/adc.2005.088831 16551792
    • (2006) Arch Dis Child , vol.91 , pp. 351-356
    • El-Radhi, A.S.1    Barry, W.2
  • 8
    • 0026130339 scopus 로고
    • Body temperature in the Nigeria neonate - Comparison of axillary and rectal temperatures
    • Body temperature in the Nigeria neonate-comparison of axillary and rectal temperatures. Akinbami FO, Sowunmi A, Afr J Med Sci 1991 1 49 52
    • (1991) Afr J Med Sci , vol.1 , pp. 49-52
    • Akinbami, F.O.1    Sowunmi, A.2
  • 9
    • 0032978024 scopus 로고    scopus 로고
    • Tympanic membrane temperature as a measure of core temperature
    • Tympanic membrane temperature as a measure of core temperature. Childs C, Harrison R, Hodkinson C, Arch Dis Child 1999 80 262 6 10.1136/adc.80.3.262 10325708 (Pubitemid 29109418)
    • (1999) Archives of Disease in Childhood , vol.80 , Issue.3 , pp. 262-266
    • Childs, C.1    Harrison, R.2    Hodkinson, C.3
  • 10
    • 0025844810 scopus 로고
    • Comparison of tympanic thermometer to rectal and oral thermometers in a pediatric emergency department
    • 10.1177/000992289103000408
    • Comparison of tympanic thermometer to rectal and oral thermometers in a pediatric emergency department. Chamberlain JM, Grandner J, Rubinoff JL, Klein BL, Waisman Y, Huey M, Clin Pediatr 1991 8 24 9 10.1177/000992289103000408
    • (1991) Clin Pediatr , vol.8 , pp. 24-29
    • Chamberlain, J.M.1    Grandner, J.2    Rubinoff, J.L.3    Klein, B.L.4    Waisman, Y.5    Huey, M.6
  • 11
    • 0025894053 scopus 로고
    • Tympanic membrane temperatures compared to rectal and oral temperatures
    • 10.1177/000992289103000409
    • Tympanic membrane temperatures compared to rectal and oral temperatures. Talo H, Macknin ML, Madendorp SV, Clin Pediatr 1991 8 30 3 10.1177/ 000992289103000409
    • (1991) Clin Pediatr , vol.8 , pp. 30-33
    • Talo, H.1    MacKnin, M.L.2    Madendorp, S.V.3
  • 12
    • 0032603842 scopus 로고    scopus 로고
    • Accuracy of tympanic temperature readings in children under 6 years of age
    • 10335248
    • Accuracy of tympanic temperature readings in children under 6 years of age. Lanham DM, Walker B, Klocke E, Jennings M, Pediatr Nurs 1999 25 39 42 10335248
    • (1999) Pediatr Nurs , vol.25 , pp. 39-42
    • Lanham, D.M.1    Walker, B.2    Klocke, E.3    Jennings, M.4
  • 14
    • 0036680024 scopus 로고    scopus 로고
    • Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting
    • DOI 10.1016/S0165-5876(02)00129-5, PII S0165587602001295
    • Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting. Kocoglu H, Goksu S, Isik M, Akturk Z, Bayazit YA, Int J Pediatr Otorhinolaryngol 2002 65 39 43 10.1016/S0165-5876(02) 00129-5 12127221 (Pubitemid 34786334)
    • (2002) International Journal of Pediatric Otorhinolaryngology , vol.65 , Issue.1 , pp. 39-43
    • Kocoglu, H.1    Goksu, S.2    Isik, M.3    Akturk, Z.4    Bayazit, Y.A.5
  • 15
    • 0028870619 scopus 로고
    • Determination of normal ear temperature with an infrared emission detection thermometer
    • 10.1016/S0196-0644(95)70349-7 7802365
    • Determination of normal ear temperature with an infrared emission detection thermometer. Chamberlain JM, Terndrup TE, Ann Emerg Med 1995 25 15 20 10.1016/S0196-0644(95)70349-7 7802365
    • (1995) Ann Emerg Med , vol.25 , pp. 15-20
    • Chamberlain, J.M.1    Terndrup, T.E.2
  • 16
    • 30344455282 scopus 로고    scopus 로고
    • An evaluation of tympanic thermometry in a paediatric emergency department
    • DOI 10.1136/emj.2004.022764
    • An evaluation of tympanic thermometry in a paediatric emergency department. EL-Radhi AS, Patel S, Emerg Med J 2006 23 40 1 10.1136/emj.2004. 022764 16373802 (Pubitemid 43056361)
    • (2006) Emergency Medicine Journal , vol.23 , Issue.1 , pp. 40-41
    • El-Radhi, A.S.1    Patel, S.2
  • 18
    • 0030911378 scopus 로고    scopus 로고
    • Temperatuurmeting bij kinderen: Met de trommelvliesinfraroodmeter en de rectale kwikthermometer even goede resultaten op de spoedeisendehulpafdeling
    • Reading children's temperatures with the tympanic infrared thermometer and the rectal mercury thermometer: Equally good results in emergency room. Draaisma JMT, Ned Tijdschr Geneeskd 1997 141 938 41 9340539 (Pubitemid 27246100)
    • (1997) Nederlands Tijdschrift voor Geneeskunde , vol.141 , Issue.19 , pp. 938-941
    • Draaisma, J.M.T.H.1    Van Lemmen, R.J.2    De Jong, A.A.M.3    Doesburg, W.4
  • 19
    • 0031215874 scopus 로고    scopus 로고
    • Comparison of body temperatures taken at different sites and the reliability of axillary temperature in screening for fever
    • Comparison of body temperatures taken at different sites and the reliability of axillary temperature in screening for fever. Osinusi K, Njinyam MN, Afr J Med Sci 1997 26 163 6
    • (1997) Afr J Med Sci , vol.26 , pp. 163-166
    • Osinusi, K.1    Njinyam, M.N.2
  • 20
    • 0028338321 scopus 로고
    • Comparison of aural infrared with traditional rectal temperatures in children from birth to age three years
    • DOI 10.1016/S0022-3476(94)70129-6
    • Comparison of aural infrared with traditional rectal temperatures in children from birth to age three years. Petersen-Smith A, Barber N, Coody DK, West MS, Yetman RJ, J Pediatr 1994 125 83 5 10.1016/S0022-3476(94)70129-6 8021794 (Pubitemid 24225186)
    • (1994) Journal of Pediatrics , vol.125 , Issue.1 , pp. 83-85
    • Petersen-Smith, A.1    Barber, N.2    Coody, D.K.3    West, M.S.4    Yetman, R.J.5
  • 21
    • 0037167250 scopus 로고    scopus 로고
    • Infrared ear thermometry compared with rectal thermometry in children: A systematic review
    • DOI 10.1016/S0140-6736(02)09783-0
    • Infrared ear thermometry compared with rectal thermometry in children: A systematic review. Craig JV, Lancaster GA, Taylor S, Williamson PR, Smyth RL, Lancet 2002 360 603 9 10.1016/S0140-6736(02)09783-0 12241932 (Pubitemid 35232194)
    • (2002) Lancet , vol.360 , Issue.9333 , pp. 603-609
    • Craig, J.V.1    Lancaster, G.A.2    Taylor, S.3    Williamson, P.R.4    Smyth, R.L.5
  • 22
    • 1642298070 scopus 로고    scopus 로고
    • Biostatistics 104: Correlational Analysis
    • 14770254
    • Biostatistics 104: Correlational Analysis. Chan YH, Singapore Med J 2003 44 614 9 14770254
    • (2003) Singapore Med J , vol.44 , pp. 614-619
    • Chan, Y.H.1
  • 23
    • 0032603842 scopus 로고    scopus 로고
    • Accuracy of tympanic temperature readings in children under 6 years of age
    • 10335248
    • Accuracy of tympanic temperature readings in children under 6 years of age. Lanham DM, Walker B, Klocke E, Jennings M, Pediatr Nurs 1999 25 39 42 10335248
    • (1999) Pediatr Nurs , vol.25 , pp. 39-42
    • Lanham, D.M.1    Walker, B.2    Klocke, E.3    Jennings, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.